Absorbed dose to the eye lens during dental radiography

被引:3
|
作者
Kanzaki, Takao [1 ]
Takahashi, Yasuyuki [2 ]
Yarita, Kazuma [1 ]
机构
[1] Gunma Univ Hosp, Dept Radiol, 3-19-15 Showa Machi, Maebashi, Gunma 3718511, Japan
[2] Hirosaki Univ, Dept Nucl Med Technol, Grad Sch Hlth Sci, 66-1 Honcho, Hirosaki, Aomori 0368564, Japan
关键词
Intraoral radiography; Panoramic radiography; Helical CT; Dental CT; Eye lens; BEAM COMPUTED-TOMOGRAPHY; MULTISECTION CT; DOSIMETRY;
D O I
10.1007/s11282-016-0267-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Radiographic examinations have clinical validation/relevance in dental practice. Dentists pay strong attention to absorbed doses to the eye lens, which is located near or inside the irradiation field. Recently, the ICRP recommended a new threshold dose for the eye lens. Therefore, we carried out eye lens dose measurements using a head phantom. We affixed fluorescence glass dosimeters to a head phantom and measured the absorbed doses during intraoral radiography, panoramic radiography, cephalography, helical scan computed tomography (helical CT), and dental cone beam computed tomography (dental CBCT). The mean absorbed dose to the eye lens in intraoral radiography examinations for maxillary incisor teeth and molar teeth was 0.11 +/- 0.09 and 0.08 +/- 0.04 mGy, respectively. Corresponding values in occlusal method examinations for the maxillary (craniocaudal angulation 70A degrees parallel to the occlusal plane) and mandibular (craniocaudal angulation 90A degrees) regions were 0.19 +/- 0.01 and 0.19 +/- 0.07 mGy, respectively. The mean value for panoramic radiography examinations was 0.07 +/- 0.02 mGy, while that for cephalography examinations in the posteroanterior projection and left lateral projection was 0.02 +/- 0.00 and 0.18 +/- 0.02 mGy, respectively. The corresponding value for helical CT was 11.87 +/- 1.12 mGy, while those for dental CBCT of the front teeth and molar teeth were 0.07 +/- 0.02 and 0.12 +/- 0.09 mGy, respectively. Eye lens doses ranged between 0.02 and 0.19 mGy in individual radiographic examinations, including CBCT. Although helical CT recorded 11.87 mGy, it was still lower than the recent ICRP-recommended threshold (500 mGy).
引用
收藏
页码:246 / 250
页数:5
相关论文
共 50 条
  • [1] Absorbed dose to the eye lens during dental radiography
    Takao Kanzaki
    Yasuyuki Takahashi
    Kazuma Yarita
    [J]. Oral Radiology, 2017, 33 : 246 - 250
  • [2] MEASUREMENTS OF INTEGRAL ABSORBED DOSE IN DENTAL RADIOGRAPHY
    SCHOENFELD, CM
    MOORE, BK
    DESAI, P
    [J]. JOURNAL OF DENTAL RESEARCH, 1976, 55 : B248 - B248
  • [3] APERTURE DIMENSIONS - INFLUENCE ON THE ABSORBED DOSE FROM DENTAL RADIOGRAPHY
    RICHTER, S
    STENSTROM, B
    [J]. JOURNAL OF DENTAL RESEARCH, 1982, 61 (04) : 566 - 566
  • [4] THE EFFECT OF FILM HOLDER DESIGN ON ABSORBED DOSE IN DENTAL RADIOGRAPHY
    OTIS, L
    GREENFIELD, H
    ZAKHARY, R
    [J]. JOURNAL OF DENTAL RESEARCH, 1990, 69 : 344 - 344
  • [5] TECHNIQUE-DEPENDENT DECREASE IN THYROID ABSORBED DOSE FOR DENTAL RADIOGRAPHY
    WOOD, RE
    BRISTOW, RG
    CLARK, GM
    NUSSBAUM, C
    TAYLOR, KW
    [J]. HEALTH PHYSICS, 1989, 56 (06): : 893 - 901
  • [6] ABSORBED DOSE IN MAMMARY RADIOGRAPHY
    KARLSSON, M
    NYGREN, K
    WICKMAN, G
    HETTINGER, G
    [J]. ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1976, 15 (03): : 252 - 258
  • [7] Eye lens dosimetry for interventional procedures - Relation between the absorbed dose to the lens and dose at measurement positions
    Geber, Therese
    Gunnarsson, Mikael
    Mattsson, Soren
    [J]. RADIATION MEASUREMENTS, 2011, 46 (11) : 1248 - 1251
  • [8] Radiation absorbed dose during special extra-oral radiography
    Farag, HI
    Latif, ZASA
    Hamed, AFA
    [J]. RADIATION PHYSICS AND CHEMISTRY, 1996, 47 (05): : 741 - 743
  • [9] PHANTOM MEASUREMENTS OF ABSORBED DOSES IN DENTAL RADIOGRAPHY
    WOHNI, T
    [J]. ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1977, 16 (02): : 194 - 198
  • [10] ORGAN ABSORBED DOSES IN INTRAORAL DENTAL RADIOGRAPHY
    RAMSEY, LJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (799): : 744 - 744