Multi-resolution rigid registration of ultrasound and CT based on similarity measures

被引:0
|
作者
Al-Sadah, J [1 ]
Madsen, E [1 ]
Mackie, T [1 ]
Zagzebski, J [1 ]
机构
[1] Univ Wisconsin, Madison, WI USA
关键词
D O I
10.1118/1.1998632
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In radiation therapy, registration of real‐time ultrasound (US) images to CT/MR images is valuable in reducing patient setup errors. Any registration process starts with rigid registration. At present practice this often is done manually by visual inspection. This study investigates the use of similarity measures as the basis of US to CT registration. This approach is potentially faster and less prone to errors compared to segmentation or landmarks based approaches. Method and Materials: A special phantom with objects visible in both CT and US was constructed and imaged. 3D‐US images were obtained using a 2D probe attached to a mechanical translator. US and CT datasets were co‐registered using an iterative registration algorithm that includes: an interpolator, a similarity metric and an optimizer all working at multiple resolution. The fitness of a similarity metric to the registration task was studied by translational and rotational perturbations of rigid transforms to compute functional trends of a similarity score versus deviation. Metrics, if effective, should guide the optimizer back to the true position. A multi‐resolution technique was employed to improve speed. Resolution degradation is guided by voxel sizes of both modalities toward isotropic resolution. A general purpose optimizer, Simplex, was used along with the nearest neighbor interpolation method. Results: The Simplex optimizer demonstrated feasibility but not speed. In evaluating similarity metrics, square differences expectedly failed in this multi‐modality registration, while mutual information (MI) and cross correlation (CC) were reasonable. Randomly rigid perturbations of up to +/− 10mm translations and +/−5° rotations from the true position converged to a visually accurate position within clinically acceptable limits of 1.0mm shifts and 1.0° rotations. Conclusion: Similarity based registration using CC or MI is feasible and effective even on raw US/CT images. Future improvement will include image filtering, adding a weighting bias, or selecting a better optimizer. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2155 / 2155
页数:1
相关论文
共 50 条
  • [1] A Feature Similarity-Based Multi-Resolution Method for Image Registration
    Wang, Zhihui
    Xie, Yuzhu
    Fan, Yuejiao
    Xu, Wenbo
    Sa, Qila
    Li, Jinlin
    [J]. PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON COMMUNICATIONS, INFORMATION MANAGEMENT AND NETWORK SECURITY, 2016, 47 : 37 - 42
  • [2] A MULTI-RESOLUTION APPROACH TO NON-RIGID REGISTRATION OF MICROSCOPY IMAGES
    Lorenz, Kevin S.
    Salama, Paul
    Dunn, Kenneth W.
    Delp, Edward J.
    [J]. 2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 198 - 201
  • [3] Multi-resolution elastic registration of CT and MR brain images
    Zheng, GY
    Li, SX
    [J]. PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 671 - 674
  • [4] Multi-resolution similarity hashing
    Roussev, Vassil
    Richard, Golden G., III
    Marziale, Lodovico
    [J]. DIGITAL INVESTIGATION, 2007, 4 (SUPPL.) : S105 - S113
  • [5] Multi-resolution image registration based on correlation technique
    Wisetphanichkij, S
    Dejhan, K
    [J]. IGARSS 2005: IEEE International Geoscience and Remote Sensing Symposium, Vols 1-8, Proceedings, 2005, : 3871 - 3875
  • [6] Medical image interpolation based on multi-resolution registration
    Leng, Juelin
    Xu, Guoliang
    Zhang, Yongjie
    [J]. COMPUTERS & MATHEMATICS WITH APPLICATIONS, 2013, 66 (01) : 1 - 18
  • [7] Similarity measures for non-rigid registration
    Rogelj, P
    Kovacic, S
    [J]. MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 569 - 578
  • [8] A protocol for evaluation of similarity measures for rigid registration
    Skerl, Darko
    Likar, Bostjan
    Pernus, Franjo
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (06) : 779 - 791
  • [9] Multi-resolution elastic registration of PET-CT images.
    Carlsen, IC
    Wischmann, HA
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 60P - 60P
  • [10] Intensity-based similarity measures evaluation for CT to ultrasound 2D registration
    Sandoval, Z.
    Dillenseger, J. -L.
    [J]. IRBM, 2013, 34 (4-5) : 278 - 282