Perfluorocarbon-perfused vitrectomy using a transconjunctival 25-gauge system

被引:18
|
作者
Quiroz-Mercado, Hugo [1 ]
Garcia-Aguirre, Gerardo
Ustariz-Gonzalez, Orlando
Martin-Avia, Jordi
Martinez-Jardon, Susana
机构
[1] Hosp Dr Luis Sanchez Bulnes, Retina Dept, Asociac Evitar La Ceguera, Mexico City 04330, DF, Mexico
[2] Hosp Clin Univ Lozano Blesa, Dept Ophthalmol, Zaragoza, Spain
关键词
vitrectomy; perfluorocarbon liquid; minimally invasive surgery; retinal detachment;
D O I
10.1097/IAE.0b013e31804b3cf9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe the feasibility of perfluorocarbon-perfused vitrectomy (PCPV) using a 25-gauge system in complicated retinal detachment cases. Methods: Thirteen nonconsecutive patients with complicated retinal detachment (either tractional secondary to proliferative diabetic retinopathy or rhegmatogenous) who would not normally be selected for 25-gauge vitrectomy were included in the study. Vitrectomy using 25-gauge ports and perfluorocarbon perfusion was performed. Real vitrectomy time, amount of perfluorocarbon liquid (PCL) used, instrument bending, feasibility of surgical maneuvers using an arbitrary scale, and anatomical and visual results were evaluated. Results: Real vitrectomy time ranged from 6.2 minutes to 17.1 minutes (mean, 10.3 minutes). Amount of PCL ranged from 8 mL to 40 mL (mean, 24.38 mL). Instruments never bent even when using a wide-angle sutured contact lens. All desired maneuvers could be performed and were facilitated by PCL. All retinas were reattached, with two cases of mild recurrent vitreous hemorrhage. Visual acuity improved in 76.9% of eyes. Conclusions: PCPV using a 25-gauge system can be performed, even in complicated cases.
引用
收藏
页码:926 / 931
页数:6
相关论文
共 50 条
  • [1] 25-gauge transconjunctival sutureless vitrectomy
    Chen, Eric
    CURRENT OPINION IN OPHTHALMOLOGY, 2007, 18 (03) : 188 - 193
  • [2] 25-gauge transconjunctival vitrectomy: Intraoperative safety
    Chen, CS
    Gupta, A
    Savar, L
    Gonzales, C
    Telander, D
    Mango, C
    Wirthlin, R
    Kreiger, AE
    Schwartz, SD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [3] 25-gauge scleral tunnel transconjunctival vitrectomy
    Shimada, Hiroyuki
    Nakashizuka, Hiroyuki
    Mori, Ryuzaburo
    Mizutani, Yoshihiro
    Hattori, Takayuki
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (05) : 871 - 873
  • [4] Expanded indications for 25-gauge transconjunctival vitrectomy
    Shimada, H
    Nakashizuka, H
    Mori, R
    Mizutani, Y
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2005, 49 (05) : 397 - 401
  • [5] Expanded Indications for 25-Gauge Transconjunctival Vitrectomy
    Hiroyuki Shimada
    Hiroyuki Nakashizuka
    Ryuzaburo Mori
    Yoshihiro Mizutani
    Japanese Journal of Ophthalmology, 2005, 49 : 397 - 401
  • [6] A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery
    Fujii, GY
    de Juan, E
    Humayun, MS
    Pieramici, DJ
    Chang, TS
    Ng, E
    Barnes, A
    Wu, SL
    Sommerville, DN
    OPHTHALMOLOGY, 2002, 109 (10) : 1807 - 1812
  • [7] Endophthalmitis after 25-gauge transconjunctival sutureless vitrectomy
    Taban, Mehran
    Ufret-Vincenty, Rafael L.
    Sears, Jonathan E.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2006, 26 (07): : 830 - 831
  • [8] Removal of silicone oil with 25-gauge transconjunctival sutureless vitrectomy, system
    Kapran, Ziya
    Acar, Nur
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2007, 27 (08): : 1059 - 1064
  • [9] 25-gauge transconjunctival vitrectomy safety: Cataract progression
    Gupta, A
    Chen, CS
    Savar, L
    Gonzales, CR
    Telander, D
    Mango, CW
    Wirthlin, R
    Kreiger, AE
    Schwartz, SD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [10] Combined microphakonit and 25-gauge transconjunctival sutureless vitrectomy
    Agarwal, Amar
    Jacob, Soosan
    Agarwal, Athiya
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11): : 1839 - 1840