Proximal stress shielding is decreased with a short stem compared with a traditional-length stem in total shoulder arthroplasty

被引:38
|
作者
Denard, Patrick J. [1 ,2 ]
Noyes, Matthew P. [1 ]
Walker, J. Brock [3 ]
Shishani, Yousef [4 ]
Gobezie, Reuben [4 ]
Romeo, Anthony A. [5 ]
Lederman, Evan [3 ,6 ]
机构
[1] Southern Oregon Orthoped, 2780 E Barnett Rd,Ste 200, Medford, OR 97530 USA
[2] Oregon Hlth & Sci Univ, Dept Orthopaed & Rehabil, Portland, OR 97201 USA
[3] Univ Arizona, Coll Med Phoenix, Dept Orthopaed Surg, Phoenix, AZ USA
[4] Cleveland Shoulder Inst, Beachwood, OH USA
[5] Rush Univ, Med Ctr, Dept Orthoped Surg, Chicago, IL USA
[6] Orthoped Clin Assoc, Phoenix, AZ USA
关键词
Total shoulder arthroplasty; short stem; humeral loosening; stress shielding; press fit; bone adaptations; metaphyseal fixation; RADIOGRAPHIC EVALUATION; BONE-RESORPTION; FOLLOW-UP;
D O I
10.1016/j.jse.2017.06.042
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This study compared the outcome and radiographic humeral adaptations after placement of a traditional-length (TL) or short-stem (SS) humeral component during total shoulder arthroplasty (TSA). The hypothesis was there would be no difference in outcome or radiographic adaptations. Methods: A multicenter retrospective review was performed of primary TSAs performed with a TL or SS press-fit humeral component. The stems were identical in geometry and coating, with the only variable being stem length. Functional outcome and radiographs were reviewed at a minimum of 2 years postoperatively in 58 TL stems and 56 SSs. Results: There were significant improvements in all range of motion and functional outcome from baseline (P < .001) but no difference between the groups (P > .05). TL stems were placed in anatomic alignment 98% of the time compared with 86% of the SS cases (P = .015), but alignment did not influence outcome. Cortical thinning was more common in the medial metaphysis with the TL stem (74%) than with the SS (50%; P = .008). Partial calcar osteolysis was seen in 31% of TL stems and in 23% of SSs (P = .348). There was no difference in loosening or shift between the 2 groups. Conclusion: There is no difference in functional outcome at short-term follow-up between a TL stem and a SS in TSA. The pattern of radiographic adaptations may differ based on stem length. Further study is needed to evaluate the mid-to long-term differences, particularly with regard to calcar osteolysis. (C) 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [1] The effects of length and width of the stem on proximal humerus stress shielding in uncemented primary reverse total shoulder arthroplasty
    Kramer, Manuel
    Olach, Martin
    Zdravkovic, Vilijam
    Manser, Melanie
    Raiss, Patric
    Jost, Bernhard
    Spross, Christian
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (02) : 663 - 672
  • [2] The effects of length and width of the stem on proximal humerus stress shielding in uncemented primary reverse total shoulder arthroplasty
    Manuel Kramer
    Martin Olach
    Vilijam Zdravkovic
    Melanie Manser
    Patric Raiss
    Bernhard Jost
    Christian Spross
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 663 - 672
  • [3] Stress shielding: short-term radiological results of the reverse shoulder arthroplasty with an anatomic proximal coated stem in proximal humeral fractures
    Francesc Goñalons-Giol
    Cristina Ventura-Parellada
    Ferran Gàmez-Baños
    Jose María Mora-Guix
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 783 - 790
  • [4] Correction to: Stress shielding: short‑term radiological results of the reverse shoulder arthroplasty with an anatomic proximal coated stem in proximal humeral fractures
    Francesc Goñalons-Giol
    Cristina Ventura-Parellada
    Ferran Gàmez-Baños
    Jose María Mora-Guix
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 2469 - 2469
  • [5] Stress shielding: short-term radiological results of the reverse shoulder arthroplasty with an anatomic proximal coated stem in proximal humeral fractures
    Giol, F. Gonalons
    Parellada, C. Ventura
    Banos, F. Gamez
    Guix, J. M. Mora
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (02) : 783 - 790
  • [6] Stress shielding of the proximal humerus in stemless anatomic total shoulder arthroplasty
    Rankin, Iain A.
    Goffin, Joaquim
    Khan, L. A. Kash
    Cairns, David
    Barker, Scott L.
    Kumar, Kapil
    SHOULDER & ELBOW, 2024, 16 (05) : 493 - 500
  • [7] Stem length in anatomic total shoulder arthroplasty: long stem, short stem, and stemless Biomechanical considerations, indications, and clinical performance
    Tross, Anna-K
    Buelhoff, Matthias
    Renkawitz, Tobias
    Kretzert, Jan Philippe
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2022, 17 (02): : 84 - 91
  • [8] Three-dimensional Volumetric Filling Ratio Predicts Stress Shielding in Short-stem Anatomic Total Shoulder Arthroplasty
    Celik, Haluk
    Chauhan, Aakash
    Flores-Hernandez, Cesar
    D'Lima, Darryl
    Hoenecke, Heinz
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2020, 28 (24) : 1047 - 1054
  • [9] The effect of stem length and width on proximal humerus stressshielding in uncemented primary reverse total shoulder arthroplasty
    Kramer, Manuel
    Supsup, Martin Olach
    Supsup, Vilijam Zdravkovic
    Supsup, Melanie Manser
    Supsup, Bernhard Jost
    Spross, Christian
    SWISS MEDICAL WEEKLY, 2023, 153 : 39S - 39S
  • [10] Radiographic analysis of humeral stress shielding after total shoulder arthroplasty with non-cemented stem
    Durchholz, H.
    Spormann, C.
    Flury, M.
    Simmen, B. R.
    Schwyzer, H. K.
    Goldhahn, J.
    Kolling, C.
    SWISS MEDICAL WEEKLY, 2010, 140 (23-24) : 15S - 15S