3He lung imaging in an open access, very-low-field human magnetic resonance imaging system

被引:38
|
作者
Mair, RW
Hrovat, MI
Patz, S
Rosen, MS
Ruset, IC
Topulos, GP
Tsai, LL
Butler, JP
Hersman, FW
Walsworth, RL
机构
[1] Harvard Smithsonian Ctr Astrophys, Cambridge, MA 02138 USA
[2] Mirtech Inc, Brockton, MA USA
[3] Brigham & Womens Hosp, Boston, MA 02115 USA
[4] Univ New Hampshire, Dept Phys, Durham, NH 03824 USA
[5] MIT, Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02139 USA
[6] Harvard Univ, Sch Publ Hlth, Boston, MA 02115 USA
关键词
orientation; lung function; lung imaging; open-access; very-low-field MRI;
D O I
10.1002/mrm.20456
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The human lung and its functions are extremely sensitive to gravity; however, the conventional high-field magnets used for most laser-polarized He-3 MRI of the human lung restrict subjects to lying horizontally. Imaging of human lungs using inhaled laser-polarized 3 He gas is demonstrated in an open-access very-low-magnetic-field (< 5 mT) MRI instrument. This prototype device employs a simple, low-cost electromagnet, with an open geometry that allows variation of the orientation of the imaging subject in a two-dimensional plane. As a demonstration, two-dimensional lung images were acquired with 4-mm in-plane resolution from a subject in two orientations: lying supine and sitting in a vertical position with one arm raised. Experience with this prototype device will guide optimization of a second-generation very-low-field imager to enable studies of human pulmonary physiology as a function of subject orientation. Magn Reson Med 53:745-749, 2005. (c) 2005 WileyLiss, Inc.
引用
收藏
页码:745 / 749
页数:5
相关论文
共 50 条
  • [1] An open-access, very-low-field MRI system for posture-dependent 3He human lung imaging
    Tsai, L. L.
    Mair, R. W.
    Rosen, M. S.
    Patz, S.
    Walsworth, R. L.
    JOURNAL OF MAGNETIC RESONANCE, 2008, 193 (02) : 274 - 285
  • [2] A system for open-access 3He human lung imaging at very low field
    Ruset, I. C.
    Tsai, L. L.
    Mair, R. W.
    Patz, S.
    Hrovat, M. I.
    Rosen, M. S.
    Muradian, I.
    Ng, J.
    Topulos, G. P.
    Butler, J. P.
    Walsworth, R. L.
    Hersman, F. W.
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2006, 29B (04) : 210 - 221
  • [3] Magnetic resonance imaging at low magnetic field using hyperpolarized 3He gas
    Suchanek, M
    Cieslar, K
    Palasz, T
    Suchanek, K
    Dohnalik, T
    Olejniczak, Z
    ACTA PHYSICA POLONICA A, 2005, 107 (03) : 491 - 506
  • [4] Recycling of 3He from lung magnetic resonance imaging
    Salhi, Z.
    Grossmann, T.
    Gueldner, M.
    Heil, W.
    Karpuk, S.
    Otten, E. W.
    Rudersdorf, D.
    Surkau, R.
    Wolf, U.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (06) : 1758 - 1763
  • [5] A Flexible Quadrature Coil for Very-Low-Field (50.4 mT) Knee Magnetic Resonance Imaging
    Wan, Cai
    He, Wei
    Xu, Zheng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [6] Posture-dependent human 3He lung imaging in an open-access MRI system:: Initial results
    Tsai, Leo L.
    Mair, Ross W.
    Li, Chih-Hao
    Rosen, Matthew S.
    Patz, Samuel
    Walsworth, Ronald L.
    ACADEMIC RADIOLOGY, 2008, 15 (06) : 728 - 739
  • [7] An optimized quadrature RF receive coil for very-low-field (50.4 mT) magnetic resonance brain imaging
    Shen, Sheng
    Kong, Xiaohan
    Meng, Fanqin
    Wu, Jiamin
    He, Yucheng
    Guo, Pan
    Xu, Zheng
    JOURNAL OF MAGNETIC RESONANCE, 2022, 342
  • [8] MRI of the lung using hyperpolarized 3He at very low magnetic field (3 mT)
    C.P. Bidinosti
    J. Choukeife
    G. Tastevin
    P.-J. Nacher
    A. Vignaud
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2004, 16 : 255 - 258
  • [9] MRI of the lung using hyperpolarized 3He at very low magnetic field (3 mT)
    Bidinosti, CP
    Choukeife, J
    Tastevin, G
    Vignaud, A
    Nacher, PJ
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 16 (06) : 255 - 258
  • [10] Polarisation and compression of 3He for magnetic resonance imaging purposes
    Geurts, DG
    van den Brand, JFJ
    Bulten, HJ
    Ferro-Luzzi, M
    Nicolay, K
    Poolman, HR
    POLARIZED GAS TARGETS AND POLARIZED BEAMS - SEVENTH INTERNATIONAL WORKSHOP, 1998, (421): : 459 - 460