Optimisation of high-temperature heat pump cascades with internal heat exchangers using refrigerants with low global warming potential

被引:51
|
作者
Mota-Babiloni, Adrian [1 ]
Mateu-Royo, Carlos [1 ]
Navarro-Esbri, Joaquin [1 ]
Moles, Francisco [1 ]
Amat-Albuixech, Marta [1 ]
Barragan-Cervera, Angel [1 ]
机构
[1] Univ Jaume 1, Dept Mech Engn & Construct, ISTENER Res Grp, Campus Riu Sec S-N, E-12071 Castellon De La Plana, Spain
关键词
Low-grade waste heat recovery; Hydrofluoroolefin (HFO); Liquid-to-suction heat exchanger; Energy efficiency; Vapour compression system; Climate change mitigation; LOW-GWP REFRIGERANTS; PERFORMANCE; SYSTEM; WATER; CYCLE; R1234ZE(E); ALTERNATIVES; RECOVERY; R1234YF; HFCS;
D O I
10.1016/j.energy.2018.09.188
中图分类号
O414.1 [热力学];
学科分类号
摘要
High-temperature heat pumps (HTHPs) based on vapour compression can be used for industrial low-grade waste heat valorisation, which can aid in mitigating climate change. Currently, the performance of HTHPs operating at high-temperatures lifts is limited; therefore, advanced configurations become an opportunity for their utilisation. This paper presents an HTHP cascade with configurations of internal heat exchangers (IHXs) that uses low GWP refrigerants in both high-stage (HS) (HCFO-1233zd(E), HFO-1336mzz(Z), HCFO-1224yd(Z), and pentane) and low-stage (LS) (HFO-1234yf, HFO-1234ze(E), butane, isobutane, and propane) cycles. Prior to the analysis and presentation of results, an optimisation of the operating conditions is performed based on intermediate temperature and IHX effectiveness in both stage cycles. Results indicate that butane and isobutane appear to be the most convenient working LS fluids from the point of view of coefficient of performance (COP). The highest system performance is obtained using pentane and HFO-1336mzz(Z) in the HS cycle. Compared to third-generation refrigerants (HFC-245fa/HFC-134a), a slight COP improvement is obtained using HCFO-1233zd(E), and HCFO-1224yd(Z). A comparable or even lower volumetric flow rate at the HS compression suction is also observed. The use of pentane/butane achieved maximum COP (3.15), which is a 13% improvement compared to COP obtained when HFC-245fa/HFC-134a is employed. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1248 / 1258
页数:11
相关论文
共 50 条
  • [1] Transient simulation of heat pumps using low global warming potential refrigerants
    Ling, Jiazhen
    Bhanot, Viren
    Alabdulkarem, Abdullah
    Aute, Vikrant
    Radermacher, Reinhard
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (05) : 658 - 665
  • [2] Techno-economic analysis of high-temperature heat pumps with low-global warming potential refrigerants for upgrading waste heat up to 150 °C
    Kosmadakis, George
    Arpagaus, Cordin
    Neofytou, Panagiotis
    Bertsch, Stefan
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2020, 226
  • [3] Performance comparison of heat pumps using low global warming potential refrigerants with optimized heat exchanger designs
    Kim, Byeongsu
    Lee, Sang Hun
    Lee, DongChan
    Kim, Yongchan
    [J]. APPLIED THERMAL ENGINEERING, 2020, 171
  • [4] Thermodynamic analysis of subcritical High-Temperature heat pump using low GWP Refrigerants: A theoretical evaluation
    Sulaiman, Adam Y.
    Cotter, Donal F.
    Le, Khoa Xuan
    Huang, Ming J.
    Hewitt, Neil J.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2022, 268
  • [5] Theoretical study of low-GWP refrigerants in high-temperature heat pump systems
    Zhou, Dong
    Meng, Zhaofeng
    Liu, Yin
    Dong, Suiju
    Zhang, Fan
    Ding, Chuangchuang
    Huo, Ziheng
    Wang, Mingming
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2023, 18 : 881 - 886
  • [6] COMPARISON ON LOW GWP REFRIGERANTS FOR HIGH TEMPERATURE HEAT PUMP
    Hu, Bin
    Yan, Yuanbo
    Wang, R. Z.
    [J]. 5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 1193 - 1202
  • [7] COMPARISON ON LOW GWP REFRIGERANTS FOR HIGH TEMPERATURE HEAT PUMP
    Hu, Bin
    Yan, Yuanbo
    Wang, R. Z.
    [J]. 5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 538 - 547
  • [8] Theoretical Global Warming Impact Evaluation of Medium and High Temperature Heat Pumps Using Low GWP Refrigerants
    Ghanbarpour, Morteza
    Mota-Babiloni, Adrian
    Badran, Bassam E.
    Khodabandeh, Rahmatollah
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (15):
  • [9] Intelligent prediction on performance of high-temperature heat pump systems using different refrigerants
    Yu Xiao-hui
    Zhang Yu-feng
    Zhang Yan
    He Zhong-lu
    Dong Sheng-ming
    Ma Xue-lian
    Yao Sheng
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2018, 25 (11) : 2754 - 2765
  • [10] Reducing the global warming impact of a household heat pump dishwasher using hydrocarbon refrigerants
    Bengtsson, Peder
    Eikevik, Trygve