Research on the Voltage Spike Suppression Strategy for Three-Phase High Frequency Link Matrix-Type Inverter

被引:5
|
作者
Wang, Youzheng [1 ]
Liu, Hongchen [1 ]
Wheeler, Patrick [2 ]
机构
[1] Harbin Inst Technol, Sch Elect Engn & Automat, Harbin 150001, Peoples R China
[2] Univ Nottingham, Dept Elect & Elect Engn, Nottingham NG7 2RD, England
关键词
Switches; Inductance; Voltage; Modulation; Parasitic capacitance; MOSFET; Zero current switching; De-re-coupling idea; flyback clamp circuit; high-frequency link matrix-type inverter (HFLMI); parasitic capacitance; voltage spike; MODULATION STRATEGY; CONVERTER;
D O I
10.1109/JESTPE.2022.3155249
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The problem of high-voltage spikes on the secondary side of a high-frequency transformer (HFT) in the commutation process of a three-phase high-frequency link matrix-type inverter (HFLMI) is studied. Considering the parasitic capacitance of MOSFETs, the mechanism of voltage spikes during HFLMI commutation is revealed. According to the characteristics of the topology, the later stage matrix converter (MC) is decoupled into two groups of conventional three-phase voltage type inverters by the de-re-coupling idea, and the space vector pulsewidth modulation (SVPWM) is carried out, respectively. The zero vector is inserted between two nonzero voltage vectors to accomplish smooth commutation for addressing the problem of voltage overshoot on the secondary side of HFT due to the switching of HFT leakage inductance and filter inductance to the same path. Due to the existence of parasitic capacitance, the voltage spikes caused by its resonance with the system's stray inductance cannot be solved by optimizing modulation strategies. In order to further suppress voltage spikes, a flyback clamp circuit is proposed to absorb the leakage inductance energy. Ultimately, a prototype with a rated power of 200 W is developed for experimental verification. The results show that the peak efficiency of three-phase HFLMI with the flyback clamp circuit is 92.6% in the full power range, the voltage spikes on the secondary side of HFT are clamped to about 1.2 times the rated voltage, and all switches realize soft-switching.
引用
收藏
页码:6070 / 6083
页数:14
相关论文
共 50 条
  • [1] A Voltage Spike Suppression Strategy Based on De-Re-Coupling Idea for the Three-Phase High-Frequency Isolated Matrix-Type Inverter
    Liu, Hongchen
    Wang, Youzheng
    Wheeler, Patrick
    Zhou, Xue
    Zhu, Kuang
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (08) : 9024 - 9034
  • [2] Leg Control Strategy of High Frequency Link Three-Phase Four-Leg Matrix Inverter
    Yan, Zhaoyang
    Bai, He
    Zhang, Zhe
    Li, Ruixue
    2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA), 2016,
  • [3] Analysis and Suppression of Voltage Harmonic Distortions of the Single-Phase High Frequency Link Matrix-Type DC-AC Converter
    Zhu, Wenjie
    Cao, Xiaoya
    Li, Xuewu
    Li, Yunfei
    Xu, Ying
    Zhou, Keliang
    IEEE ACCESS, 2022, 10 : 130273 - 130284
  • [4] A controller for the three-phase to three-phase matrix converter and for the voltage source three-phase inverter without dc-link capacitor
    Filho M.E.O.
    Gazoli J.R.
    Filho A.J.S.
    Ruppert E.
    Controle y Automacao, 2010, 21 (05): : 534 - 545
  • [5] Research on Single phase Z source high frequency link matrix inverter and modulation strategy
    Yan Zhaoyang
    Sun Zhe
    Pang Jianxia
    Liang Chenyang
    Li Jianxia
    Yang Lijun
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 7348 - 7353
  • [6] Principle and realization of HPWM strategy for three-phase inverter based on high frequency linked matrix converter
    Yan, Zhaoyang
    Jia, Minli
    Zhang, Chunjiang
    Wu, Weiyang
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2010, 25 (11): : 113 - 121
  • [7] Three-phase Four-Leg High Frequency Link Matrix Rectifier and Its Modulation Strategy
    Yan, Zhaoyang
    Liang, Chenyang
    Kang, Ming
    Li, Jianxia
    Yang, Lijun
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 2108 - 2113
  • [8] Comparison of the Unbalanced Faults in Three-Phase Resistive and Matrix-Type SFCLs
    Choi, Hyo-Sang
    Cho, Yong-Sun
    Jung, Byung-Ik
    Chung, Dong-Chul
    Fathy, Aly
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 1215 - 1218
  • [9] Current-Fed Isolated Three-Phase Matrix-Type Grid Inverter With Soft-Switching Capability
    Xu, Yang
    Wang, Zheng
    Liu, Pengcheng
    Zou, Zhixiang
    Xiao, Huafeng
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (04) : 3292 - 3302
  • [10] Research on control strategy of load voltage unbalance problem for three-phase combined inverter
    Ren, BiYing
    Zhang, Meng
    Zhao, XinRong
    Sun, XiangDong
    PROCEEDINGS OF THE 2016 IEEE 11TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2016, : 2061 - 2065