LONG TERM SIMULATION OF HORIZONTAL GROUND HEAT EXCHANGER FOR GROUND SOURCE HEAT PUMP

被引:0
|
作者
Kayaci, Nurullah [1 ]
Demir, Hakan [1 ]
Atayilmaz, S. Ozgur [1 ]
Agra, Ozden [1 ]
机构
[1] Yildiz Tech Univ, Dept Mech Engn, Heat & Thermodynam Div, TR-34349 Istanbul, Turkey
关键词
MASS-TRANSFER MODEL; BURIED PIPE; SYSTEM;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The earth is an energy resource which has more suitable and stable temperatures than air. Ground Source Heat Pumps (GSHPs) were developed to use ground energy for residential heating. The most important part of a GSHP is the Ground Heat Exchanger (GHE) that consists of pipes buried in the soil and is used for transferring heat between the soil and the heat exchanger of the GSHP. Soil composition, density, moisture and burial depth of pipes affect the size of a GHE. There are plenty of works on ground source heat pumps and ground heat exchangers in the literature. Most of the works on ground heat exchangers are based on the heat transfer in the soil and temperature distribution around the coil. Some of the works for thermo-economic optimization of thermal systems are based on thermodynamic cycles. GHEs is commonly sized according to short time (one year or less) simulation algorithms. Variation of soil temperature in long time period is more important and, therefore, long term simulation is required to be assure the performance of the GSHP system. In this study, long time (10 years) simulation for parallel pipe GHE of a GSHP system was performed numerically with dynamical boundary conditions. In the numerical study ANSYS CFD package was used. This package uses a technique based on control volume theory to convert the governing equations to algebraic equations so they can be solved numerically. The control volume technique works by performing the integration of the governing equations about each control volume, and then generates discretization of the equations which conserve each quantity based on control volume. Thermal boundary conditions can be defined in four different types in ANSYS Fluent: Constant heat flux, constant temperature,convection-radiation and convection. In this study, periodic variation of air temperature boundary at upper surface condition is applied, the lateral and bottom surface of the solution domain are defined as adiabatic wall type boundary condition; the pipe inner surface is taken as wall with a constant heat flux. In order to provide the periodic variation of air temperature boundary at upper surface condition a User Defined Function (UDF) was written and interpreted in ANSYS Fluent. Likewise, a UDF was also written to give constant heat flux intermittently for the pipe inner surface. Constant heat flux of 10, 20, 30 W per unit length of pipe used for calculations. Effects of distance between pipes and thermal conductivity on temperature distribution in the soil were investigated. Heat transfer in the soil is time dependent three dimensional heat conduction with dynamical boundary conditions. Temperature distribution in soil were obtained and storage effect of the soil has also been investigated. An optimization methodology based on long term simulation of GHE was suggested.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Research on ground heat exchanger of Ground Source Heat Pump technique
    LIU Dong-sheng
    [J]. Global Geology, 2004, (02) : 196 - 199
  • [2] Long term coupled simulation for ground source heat pump and underground heat exchangers
    Li, Shuhong
    Dong, Kefeng
    Wang, Jinyong
    Zhang, Xiaosong
    [J]. ENERGY AND BUILDINGS, 2015, 106 : 13 - 22
  • [3] Experimental study of ground-source heat pump systems with horizontal heat exchanger
    Sun, Chun-Wu
    Zhang, Su-Yun
    Liu, Xian-Ying
    [J]. Chongqing Jianzhu Daxue Xuebao/Journal of Chongqing Jianzhu University, 2001, 23 (06):
  • [4] Numerical modelling of transient soil temperature distribution for horizontal ground heat exchanger of ground source heat pump
    Kayaci, Nurullah
    Demir, Hakan
    [J]. GEOTHERMICS, 2018, 73 : 33 - 47
  • [5] Experimental Study Of Heating-cooling Combined Ground Source Heat Pump System with Horizontal Ground Heat Exchanger
    Hu, Ying-Ning
    Peng, Ban-Jun
    Hu, Shan-Shan
    Lin, Jun
    [J]. SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 398 - 404
  • [6] Numerical simulation for the optimum design of ground source heat pump system using building foundation as horizontal heat exchanger
    Nam, Yujin
    Chae, Ho-Byung
    [J]. ENERGY, 2014, 73 : 933 - 942
  • [7] Experimental validation of a ground heat exchanger model in a hybrid ground source heat pump
    Pertzborn, Amanda
    Hackel, Scott
    Nellis, Greg
    Klein, Sanford
    [J]. HVAC&R RESEARCH, 2011, 17 (06): : 1101 - 1114
  • [8] Influence of hydration heat on heat transfer effect of ground heat exchanger of ground source heat pump in summer
    Xia, Caichu
    Liu, Zhifang
    Xiao, Suguang
    Huang, Man
    [J]. Tongji Daxue Xuebao/Journal of Tongji University, 2015, 43 (09): : 1332 - 1338
  • [9] Performance study of heat pipe heat exchanger for ground source heat pump
    Hsieh, Jui Ching
    Lin, David T.W.
    Shin, Long Der
    [J]. 1600, Chinese Mechanical Engineering Society (35): : 165 - 170
  • [10] Numerical Simulation and Analysis for the U-tube Heat Exchanger of Ground Source Heat Pump
    Chang Zhen
    Guo Min
    [J]. 2013 32ND CHINESE CONTROL CONFERENCE (CCC), 2013, : 8713 - 8717