Usefulness of liquid-based cytology in hormone receptor analysis of breast cancer specimens

被引:22
|
作者
Nishimura, Rieko [1 ]
Aogi, Kenjiro [2 ]
Yamamoto, Tamami [1 ]
Takabatake, Daisuke [2 ]
Takashima, Seiki [2 ]
Teramoto, Norihiro [3 ]
Kagawa, Akihiro [1 ]
Morita, Sachiko [1 ]
机构
[1] Natl Hosp Org, Shikoku Canc Ctr, Dept Clin Lab, Matsuyama, Ehime 7910280, Japan
[2] Natl Hosp Org, Shikoku Canc Ctr, Dept Breast Oncol, Matsuyama, Ehime 7910280, Japan
[3] Natl Hosp Org, Shikoku Canc Ctr, Dept Pathol, Matsuyama, Ehime 7910280, Japan
关键词
Breast cancer; Hormone receptor; Immunohistochemistry; Fine needle aspirate; Liquid-based cytology; FINE-NEEDLE-ASPIRATION; PROGESTERONE-RECEPTOR; ESTROGEN-RECEPTOR; CARCINOMA; THINPREP; EXPRESSION; SECTIONS; BIOPSIES; IMPACT;
D O I
10.1007/s00428-010-1025-2
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Immunohistochemical (IHC) analysis of the hormone receptor (HR) in breast cancer cytology is an important issue nowadays. Several studies have shown discrepancy in the HR status between the primary tumor and metastases. Cytology can be used for patients with metastatic disease. Although cytological assessment of HR is an excellent method, it has not been routinely used because of the difficulty in consistently preparing multiple good quality slides. Liquid-based cytology (LBC) preparation is considered as the key to resolving the aforementioned problem; however, few studies have reported the HR assessment in breast cancer using LBC. Therefore, the HR status of LBC slides from 82 breast cancers was compared with that of the corresponding surgical specimens. The HR assay in both the LBC slides and surgical specimens was conducted by IHC using an autostainer. For the IHC staining, the protocol recommended by the manufacturer for paraffin-embedded sections was used for both the cytology and histology specimens. The HR results of the cytology agreed with those of the histology in 80 of the 82 cases (accuracy rate, 98%) for estrogen receptor, and in 78 of the 82 cases (accuracy rate, 95%) for progesterone receptor. The overall accuracy of the HR status on the cytology and the histology was 99% in 81 of the 82 cases. In conclusion, in HR analysis of breast cancers, LBC followed by IHC using an autostainer was useful for the standard processing of cytological specimens and showed a good correlation with the results of analysis on the histology specimens.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 50 条
  • [1] Usefulness of liquid-based cytology in hormone receptor analysis of breast cancer specimens
    Rieko Nishimura
    Kenjiro Aogi
    Tamami Yamamoto
    Daisuke Takabatake
    Seiki Takashima
    Norihiro Teramoto
    Akihiro Kagawa
    Sachiko Morita
    Virchows Archiv, 2011, 458 : 153 - 158
  • [2] Clinical usefulness of liquid-based cytology in hormone receptor analysis for fine needle aspiration specimens of breast cancer patients
    Aogi, K.
    Takabatake, D.
    Takashima, S.
    Nishimura, R.
    Yamamoto, T.
    Morita, S.
    Kagawa, A.
    Teramoto, N.
    BREAST, 2011, 20 : S21 - S21
  • [3] Immunocytochemistry using Liquid-based Cytology: A Tool in Hormone Receptor Analysis of Breast Cancer
    Tripathy, Kalpalata
    Mishra, Aparajita
    Singh, Ajit K.
    Panda, Pragnya L.
    Mahapatra, Arup
    Lenka, Anusaya
    JOURNAL OF CYTOLOGY, 2018, 35 (04) : 260 - 264
  • [4] HORMONE RECEPTOR STATUS OF BREAST CANCER IN FINE NEEDLE ASPIRATES PREPARED BY LIQUID-BASED CYTOLOGY
    Nishimura, R.
    Aogi, K.
    Yamamoto, T.
    Takabatake, D.
    Takashima, S.
    Kagawa, A.
    Morita, S.
    Teramoto, N.
    ACTA CYTOLOGICA, 2010, 54 (03) : 442 - 442
  • [5] Usefulness of liquid-based preparation in urine cytology
    Hwang, Eu Chang
    Park, Seong Hoon
    Jung, Seung Il
    Kwon, Dong Deuk
    Park, Kwangsung
    Ryu, Soo Bang
    Park, Chang Soo
    INTERNATIONAL JOURNAL OF UROLOGY, 2007, 14 (07) : 626 - 629
  • [6] Control specimens for immunocytochemistry in liquid-based cytology
    Hansen, T.
    Pedersen, H.
    Brauner, V.
    Hariri, J.
    CYTOPATHOLOGY, 2011, 22 (04) : 243 - 246
  • [7] The usefulness of liquid-based cytology of bronchoalveolar lavage fluid combined with bronchial brush specimens in lung cancer diagnosis
    Ma, Shanni
    Yu, Xuechan
    Jin, Xiaoyan
    Qiu, Feng
    Chen, Xueqin
    Wang, Ran
    Cao, Chao
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2022, 50 (11)
  • [8] Next-generation sequencing in residual liquid-based cytology specimens for cancer genome analysis
    Yamaguchi, Tomomi
    Akahane, Toshiaki
    Harada, Ohi
    Kato, Yasutaka
    Aimono, Eriko
    Takei, Hidehiro
    Tasaki, Takashi
    Noguchi, Hirotsugu
    Nishihara, Hiroshi
    Kamata, Hajime
    Tanimoto, Akihide
    DIAGNOSTIC CYTOPATHOLOGY, 2020, 48 (11) : 965 - 971
  • [9] Comprehensive validation of liquid-based cytology specimens for next-generation sequencing in cancer genome analysis
    Akahane, Toshiaki
    Yamaguchi, Tomomi
    Kato, Yasutaka
    Yokoyama, Seiya
    Hamada, Taiji
    Nishida, Yukari
    Higashi, Michiyo
    Nishihara, Hiroshi
    Suzuki, Shinsuke
    Ueno, Shinichi
    Tanimoto, Akihide
    PLOS ONE, 2019, 14 (06):
  • [10] The evaluation of liquid-based 'ThinPrep' cytology of intrapulmonary specimens against conventional specimens
    Kakihana, Masatoshi
    Kato, Yasuhumi
    Uchida, Osamu
    Kajiwara, Naohiro
    Ohira, Tatsuo
    Ikeda, Norihiko
    JOURNAL OF THORACIC ONCOLOGY, 2009, 4 (09) : S498 - S498