Three-dimensional quantitative assessment of ablation margins based on registration of pre- and post-procedural MRI and distance map

被引:28
|
作者
Tani, Soichiro [1 ,2 ]
Tatli, Servet [1 ]
Hata, Nobuhiko [1 ]
Garcia-Rojas, Xavier [3 ]
Olubiyi, Olutayo I. [1 ]
Silverman, Stuart G. [1 ]
Tokuda, Junichi [1 ]
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Radiol, 75 Francis St, Boston, MA 02115 USA
[2] Shiga Univ Med Sci, Biomed Innovat Ctr, Dept Surg, Seta Tsukinowa Cho, Otsu, Shiga 5202192, Japan
[3] Texas Med Ctr, 2450 Holcombe Blvd,Suite 10, Houston, TX 77021 USA
关键词
Liver ablation; MRI; Image-guided intervention; Ablation margin; Image registration; RADIOFREQUENCY THERMAL ABLATION; GUIDED PERCUTANEOUS CRYOTHERAPY; SMALL HEPATOCELLULAR-CARCINOMA; UNRESECTABLE HEPATIC-TUMORS; IMAGE REGISTRATION; LOCAL RECURRENCE; LIVER-TUMORS; NONRIGID REGISTRATION; SINGLE SESSION; RISK-FACTORS;
D O I
10.1007/s11548-016-1398-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Contrast-enhanced MR images are widely used to confirm the adequacy of ablation margin after liver ablation for early prediction of local recurrence. However, quantitative assessment of the ablation margin by comparing pre- and post-procedural images remains challenging. We developed and tested a novel method for three-dimensional quantitative assessment of ablation margin based on non-rigid image registration and 3D distance map. Our method was tested with pre- and post-procedural MR images acquired in 21 patients who underwent image-guided percutaneous liver ablation. The two images were co-registered using non-rigid intensity-based registration. After the tumor and ablation volumes were segmented, target volume coverage, percent of tumor coverage, and Dice similarity coefficient were calculated as metrics representing overall adequacy of ablation. In addition, 3D distance map around the tumor was computed and superimposed on the ablation volume to identify the area with insufficient margins. For patients with local recurrences, the follow-up images were registered to the post-procedural image. Three-dimensional minimum distance between the recurrence and the areas with insufficient margins was quantified. The percent tumor coverage for all nonrecurrent cases was 100 %. Five cases had tumor recurrences, and the 3D distance map revealed insufficient tumor coverage or a 0-mm margin. It also showed that two recurrences were remote to the insufficient margin. Non-rigid registration and 3D distance map allow us to quantitatively evaluate the adequacy of the ablation margin after percutaneous liver ablation. The method may be useful to predict local recurrences immediately following ablation procedure.
引用
收藏
页码:1133 / 1142
页数:10
相关论文
共 50 条
  • [1] Three-dimensional quantitative assessment of ablation margins based on registration of pre- and post-procedural MRI and distance map
    Soichiro Tani
    Servet Tatli
    Nobuhiko Hata
    Xavier Garcia-Rojas
    Olutayo I. Olubiyi
    Stuart G. Silverman
    Junichi Tokuda
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 1133 - 1142
  • [2] Determinants of Pre- and Post-Procedural Neurological Assessment, and Outcome of Carotid Endarterectomy or Stenting
    Kallmayer, Michael
    Knappich, Christoph
    Kirchhoff, Felix
    Bohmann, Bianca
    Lohe, Vanessa
    Naher, Shamsun
    Eckstein, Hans-Henning
    Kuehnl, Andreas
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (14)
  • [3] The Crucial Role of Cardiac Imaging in Transcatheter Aortic Valve Replacement (TAVR): Pre- and Post-procedural Assessment
    Al-Najafi S.
    Sanchez F.
    Lerakis S.
    Current Treatment Options in Cardiovascular Medicine, 2016, 18 (12)
  • [4] Elastic Registration Algorithm Based on Three-dimensional Pulmonary MRI in Quantitative Assessment of Severity of Idiopathic Pulmonary Fibrosis
    Yang, Xiaoyan
    Yu, Pengxin
    Xu, Wenqing
    Sun, Haishuang
    Duan, Jianghui
    Han, Yueyin
    Zhu, Lili
    Xie, Bingbing
    Geng, Jing
    Luo, Sa
    Wang, Shiyao
    Ren, Yanhong
    Zhang, Rongguo
    Liu, Min
    Dai, Huaping
    Wang, Chen
    JOURNAL OF THORACIC IMAGING, 2023, 38 (06) : 358 - 366
  • [5] Three-Dimensional Quantitative Micromorphology of Pre- and Post-Implanted Engineered Heart Valve Tissues
    Chad E. Eckert
    Brandon T. Mikulis
    Danielle Gottlieb
    Dane Gerneke
    Ian LeGrice
    Robert F. Padera
    John E. Mayer
    Frederick J. Schoen
    Michael S. Sacks
    Annals of Biomedical Engineering, 2011, 39 : 205 - 222
  • [6] Three-Dimensional Quantitative Micromorphology of Pre- and Post-Implanted Engineered Heart Valve Tissues
    Eckert, Chad E.
    Mikulis, Brandon T.
    Gottlieb, Danielle
    Gerneke, Dane
    LeGrice, Ian
    Padera, Robert F.
    Mayer, John E.
    Schoen, Frederick J.
    Sacks, Michael S.
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (01) : 205 - 222
  • [7] Three-dimensional finite element-based deformable registration of pre- and intraoperative prostate imaging
    Bharatha, A
    Hirose, M
    Hata, N
    Warfield, SK
    Ferrant, M
    Zou, KH
    RADIOLOGY, 2001, 221 : 224 - 224
  • [8] Pre- and post-contrast three-dimensional double inversion-recovery MRI in human glioblastoma
    Harris, Robert J.
    Cloughesy, Timothy F.
    Pope, Whitney B.
    Godinez, Sergio
    Natsuaki, Yutaka
    Nghiemphu, Phioanh L.
    Meyer, Heiko
    Paul, Dominik
    Behbahanian, Yalda
    Lai, Albert
    Ellingson, Benjamin M.
    JOURNAL OF NEURO-ONCOLOGY, 2013, 112 (02) : 257 - 266
  • [9] Pre- and post-contrast three-dimensional double inversion-recovery MRI in human glioblastoma
    Robert J. Harris
    Timothy F. Cloughesy
    Whitney B. Pope
    Sergio Godinez
    Yutaka Natsuaki
    Phioanh L. Nghiemphu
    Heiko Meyer
    Dominik Paul
    Yalda Behbahanian
    Albert Lai
    Benjamin M. Ellingson
    Journal of Neuro-Oncology, 2013, 112 : 257 - 266
  • [10] Evaluation of three-dimensional finite element-based deformable registration of pre- and intraoperative prostate imaging
    Bharatha, A
    Hirose, M
    Hata, N
    Warfield, SK
    Ferrant, M
    Zou, KH
    Suarez-Santana, E
    Ruiz-Alzola, J
    D'Amico, A
    Cormack, RA
    Kikinis, R
    Jolesz, FA
    Tempany, CMC
    MEDICAL PHYSICS, 2001, 28 (12) : 2551 - 2560