Effect of firing protocols on cohesive failure of all-ceramic crowns

被引:67
|
作者
Rues, Stefan [1 ]
Kroger, Elke [1 ]
Muller, Denise [1 ]
Schmitter, Marc [1 ]
机构
[1] Univ Heidelberg, Dept Prosthodont, Sch Dent, MZK 2, D-69120 Heidelberg, Germany
关键词
Cohesive failure; All ceramic crowns; In vitro test; Firing protocol; Ageing; FIXED PARTIAL DENTURES; ZIRCONIA FRAMEWORKS; DENTAL PROSTHESES; STRENGTH; FRACTURE; RESTORATIONS; MODE;
D O I
10.1016/j.jdent.2010.08.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The mechanical properties of veneering material in all ceramic restorations are inferior to those of high strength ceramics The objective of this study was to assess the effect of three different firing protocols (different cooling times) on cohesive failure of veneered all ceramic crowns using a newly developed in vitro test design Methods A prepared anterior maxillary incisor was used to produce geometrically identical crowns (n = 68) with a zirconia framework 0 4 mm thick veneered with two different ceramics and prepared by use of three different firing protocols Twenty crowns were loaded until fracture without artificial ageing the other crowns underwent thermocycling and chewing simulation before ultimate load testing Statistical analysis was performed using non parametric tests Results The results showed that a reduced temperature decrease after firing led to better performance of all ceramic anterior crowns in the in vitro tests A significant difference with regard to firing protocol (p = 0 006) was observed for one veneering ceramic material only however Conclusion It can therefore be concluded that the test design presented enabled sensitive measurement of the effect of firing protocol on cohesive failure of all ceramic crowns The modified firing protocol with 6 mm additional cooling time resulted in greater resistance (C) 2010 Elsevier Ltd All rights reserved
引用
收藏
页码:987 / 994
页数:8
相关论文
共 50 条
  • [1] The effect of adhesive failure and defects on the stress distribution in all-ceramic crowns
    Liu, Yonggang
    Xu, Yuanzhi
    Su, Bo
    Arola, Dwayne
    Zhang, Dongsheng
    [J]. JOURNAL OF DENTISTRY, 2018, 75 : 74 - 83
  • [2] EFFECT OF CEMENTS ON THE STRENGTH OF ALL-CERAMIC CROWNS
    MANTE, FK
    PHILLIPS, K
    KOROSTOFF, E
    [J]. JOURNAL OF DENTAL RESEARCH, 1995, 74 : 39 - 39
  • [3] Why all-ceramic crowns?
    Christensen, GJ
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1997, 128 (10): : 1453 - 1455
  • [4] All-ceramic silica/glass-based crowns - clinical protocols
    Mizrahi, B.
    [J]. BRITISH DENTAL JOURNAL, 2011, 211 (06) : 257 - 262
  • [5] All-ceramic silica/glass-based crowns – clinical protocols
    B. Mizrahi
    [J]. British Dental Journal, 2011, 211 : 257 - 262
  • [6] Numerical Simulation of Failure Process of VITA All-Ceramic Crowns
    Fan, Cheng
    Chen, Geng
    Wang, Shan Shan
    [J]. PROGRESS IN MATERIALS AND PROCESSES, PTS 1-3, 2013, 602-604 : 544 - 547
  • [7] Effect of indenter material on reliability of all-ceramic crowns
    Lorenzoni, Fabio C.
    Bonfante, Estevam A.
    Valverde, Guilherme B.
    Coelho, Paulo G.
    Bonfante, Gerson
    Thompson, Van P.
    Silva, Nelson R. F. A.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 108
  • [8] Probability of fracture of all-ceramic crowns
    Chai, J
    Takahashi, Y
    Sulaiman, F
    Chong, KH
    Lautenschlager, EP
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2000, 13 (05) : 420 - 424
  • [9] Fracture strength of all-ceramic crowns
    Sobrinho, LC
    Cattell, MJ
    Knowles, JC
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (10) : 555 - 559
  • [10] Is the rush to all-ceramic crowns justified?
    Christensen, Gordon J.
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2014, 145 (02): : 192 - 194