Use of a Novel Absorbable Barbed Plastic Surgical Suture Enables a "Self-Cinching" Technique of Vesicourethral Anastomosis During Robot-Assisted Prostatectomy and Improves Anastomotic Times

被引:75
|
作者
Tewari, Ashutosh K.
Srivastava, Abhishek
Sooriakumaran, Prasanna
Slevin, Adam
Grover, Sonal
Waldman, Olivia
Rajan, Sivaram
Herman, Michael
Berryhill, Roy, Jr.
Leung, Robert
机构
[1] New York Presbyterian Hosp, Weill Cornell Med Coll, Dept Urol, James Buchanan Brady Fdn,Inst Prostate Canc, New York, NY USA
[2] New York Presbyterian Hosp, LeFrak Ctr Robot Surg, New York, NY USA
关键词
RADICAL RETROPUBIC PROSTATECTOMY; RECTOURETHRALIS MUSCLE; URETHROVESICAL ANASTOMOSIS; APICAL DISSECTION; CONTINENCE; RHABDOSPHINCTER; PRESERVATION; OUTCOMES;
D O I
10.1089/end.2010.0316
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To demonstrate a novel technique of self-cinching anastomosis using a barbed and looped suture during robot-assisted radical prostatectomy (RARP). Patients and Methods: This is a feasibility study of 50 consecutive patients who underwent this novel self-cinching anastomotic technique using a V-Loc (TM) 180 absorbable barbed suture after RARP for clinically localized prostate cancer. The results were then compared with 50 consecutive patients who underwent RARP by the same surgeon before this new technique. We examined whether this novel technique had any effects on posterior reconstruction time, vesicourethral anastomosis time, and thus total reconstruction and operative time by inference. Results: The V-Loc 180 group had significantly shorter posterior reconstruction (40 seconds vs 60 seconds; P - < 0.001) and vesicourethral anastomotic times (7 min vs 12 min; P - < 0.001). By inference, this meant that total reconstruction and operative times were also significantly less (8 minutes vs 13.5 min; P = < 0.001 and 106 min vs 114.5 minutes; P = < 0.001, respectively). Conclusion: We have shown that this technique is feasible and improves posterior reconstruction and anastomotic times. Further follow-up will determine any benefits of this technique on anastomotic urinary leak rates, continence, and catheter removal times.
引用
收藏
页码:1645 / 1650
页数:6
相关论文
共 39 条
  • [2] USE OF A BARBED ABSORBABLE SUTURE IMPROVES VESICOURETHRAL RECONSTRUCTION TIMES DURING ROBOTIC PROSTATECTOMY
    Srivastava, A.
    Sooriakumaran, P.
    Grover, S.
    Roy, S.
    Rajan, S.
    El-Douaihy, Y.
    Idler, J.
    Leung, R.
    Tewari, A.
    EUROPEAN UROLOGY SUPPLEMENTS, 2011, 10 (02) : 350 - 350
  • [3] Use of a novel bidirectional suture in vesicourethral anastomosis during robot-assisted laparoscopic prostatectomy
    Jegathesan, T.
    Png, K. S.
    BJU INTERNATIONAL, 2014, 113 : 26 - 26
  • [4] V-LOC™ BARBED SUTURE TO FACILITATE VESICOURETHRAL ANASTOMOSIS DURING ROBOT-ASSISTED LAPAROSCOPIC RADICAL PROSTATECTOMY
    Turpen, R. M.
    Atalah, H.
    Su, L.
    JOURNAL OF ENDOUROLOGY, 2010, 24 : A334 - A334
  • [5] Bidirectional barbed suture for posterior musculofascial reconstruction and knotless vesicourethral anastomosis during robot-assisted radical prostatectomy
    Porreca, Angelo
    D'Agostino, Daniele
    Dandrea, Matteo
    Salvaggio, Antonio
    Del Rosso, Alessandro
    Cappa, Emanuele
    Zuccala, Alessio
    Romagnoli, Daniele
    Bianchi, Lorenzo
    Schiavina, Riccardo
    MINERVA UROLOGICA E NEFROLOGICA, 2018, 70 (03) : 319 - 325
  • [6] Vesicourethral anastomosis using V-Loc (TM) barbed suture during robot-assisted radical prostatectomy
    Chapman, Stephen
    Turo, Rafal
    Cross, William
    CENTRAL EUROPEAN JOURNAL OF UROLOGY, 2011, 64 (04) : 236 - 236
  • [7] Recurrent Foley catheter puncture and displacement: a complication of the use of barbed polyglyconate suture to facilitate vesicourethral anastomosis during robot-assisted radical prostatectomy
    Toussi A.
    Turner R.M.
    II
    Corcoran A.T.
    Jackman S.V.
    Journal of Robotic Surgery, 2014, 8 (4) : 379 - 380
  • [8] VESICOURETHRAL ANASTOMOSIS IN ROBOT-ASSISTED RADICAL PROSTATECTOMY: THE SINGLE ARMED SELF-RETAINING RUNNING SUTURE TECHNIQUE
    Wagner, C.
    Schuette, A.
    Labanaris, A.
    Zugor, V
    Witt, J. H.
    EUROPEAN UROLOGY SUPPLEMENTS, 2011, 10 (02) : 350 - 350
  • [9] Use of a barbed suture for continuous urethro-vesical anastomosis during robot-assisted laparoscopic radical prostatectomy
    Pan, David
    Sengupta, Shomik
    Webb, David R.
    JOURNAL OF ROBOTIC SURGERY, 2012, 6 (03) : 241 - 242
  • [10] Use of a barbed suture for continuous urethro-vesical anastomosis during robot-assisted laparoscopic radical prostatectomy
    David Pan
    Shomik Sengupta
    David R. Webb
    Journal of Robotic Surgery, 2012, 6 (3) : 241 - 242