Improved methods for performing multivariate analysis and deriving background spectra in atmospheric open-path FT-IR monitoring

被引:11
|
作者
Hong, DW [1 ]
Cho, SY [1 ]
机构
[1] Inha Univ, Dept Environm Engn, Inchon 402751, South Korea
关键词
open-path FT-IR; classical least squares; CLS; L-1; minimization; volatile organic compounds;
D O I
10.1366/000370203321558218
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Open-path Fourier transform infrared spectrometry (OP/FT-IR) may improve the temporal and spatial resolution in air pollutant measurements compared to conventional sampling methods. However, a successful OP/FT-IR operation requires an experienced analyst to resolve chemical interference as well as to derive a suitable background spectrum. The present study aims at developing a systematic method of handling the OP/FT-IR derived spectra for the measurement of photochemical oxidants and volatile organic compounds (VOCs) in urban areas. A classical least-squares (CLS) method, the most frequently used regression method in OP/FT-IR, is modified to constrain all the analyzed chemical species concentrations within a physically reasonable range. This new CLS method, named constrained CLS, may save the effort of predetermining the chemical species to be analyzed. A new background spectrum generation method is also introduced to more efficiently handle chemical interferences. Finally, CLS is shown to be prone to propagating errors in the case that a few data points contain a significant amount of error. The L1-norm minimization method reduces this error propagation to considerably increase the stability compared to CLS. The presently developed analysis software based on these approaches is compared with the other conventional CLS method using an artificially made single-beam spectrum as well as a field single-beam spectrum.
引用
收藏
页码:299 / 308
页数:10
相关论文
共 37 条
  • [1] AN INTRODUCTION TO OPEN-PATH FT-IR ATMOSPHERIC MONITORING
    MARSHALL, TL
    CHAFFIN, CT
    HAMMAKER, RM
    FATELEY, WG
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (05) : A224 - A232
  • [2] Open-path FT-IR takes the long view
    Newman, AR
    ANALYTICAL CHEMISTRY, 1997, 69 (01) : A43 - A47
  • [3] Encoding FT-IR spectra in a Hopfield network and its application to compound identification in open-path FT-IR measurements
    Yang, Husheng
    Griffiths, Peter R.
    Analytical Chemistry, 71 (16): : 3356 - 3364
  • [4] Completely automated open-path FT-IR spectrometry
    Griffiths, Peter R.
    Shao, Limin
    Leytem, April B.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (01) : 45 - 50
  • [5] Completely automated open-path FT-IR spectrometry
    Peter R. Griffiths
    Limin Shao
    April B. Leytem
    Analytical and Bioanalytical Chemistry, 2009, 393 : 45 - 50
  • [6] Encoding FT-IR spectra in a hopfield network and its application to compound identification in open-path FT IR measurements
    Yang, HS
    Griffiths, PR
    ANALYTICAL CHEMISTRY, 1999, 71 (16) : 3356 - 3364
  • [7] Open-path FT-IR spectrometry: is completely unattended operation feasible
    Griffiths, PR
    Hart, BK
    Yang, HS
    Berry, RJ
    TALANTA, 2000, 53 (01) : 223 - 231
  • [8] Open path FT-IR spectra analysis method for monitoring of environment and processes with varying conditions
    Cieszczyk, Slawomir
    Komada, Pawel
    Akhmetova, Ardak
    Mussabekova, Assel
    ROCZNIK OCHRONA SRODOWISKA, 2016, 18 : 218 - 234
  • [9] Application of neural networks to compound identification in open-path FT-IR spectrometry
    Yang, HS
    Griffiths, PR
    FOURIER TRANSFORM SPECTROSCOPY, 1998, (430): : 245 - 248
  • [10] Improved strategies for quantitative evaluation of atmospheric FTIR spectra obtained in open-path monitoring
    Müller, U
    Heise, HM
    Mosebach, H
    Gärtner, AG
    Häusler, T
    FIELD ANALYTICAL CHEMISTRY AND TECHNOLOGY, 1999, 3 (03): : 141 - 159