Elimination of zero sequence circulating currents in paralleled three-level T-type inverters with a model predictive control strategy

被引:23
|
作者
Wang, Xiaodong [1 ,2 ]
Zou, Jianxiao [1 ]
Peng, Ying [1 ]
Xie, Chuan [1 ]
Li, Kai [1 ]
Zapata, Josep Maria Guerrero [3 ]
机构
[1] Univ Elect Sci & Technol China, Sch Automat Engn, Chengdu, Sichuan, Peoples R China
[2] China Acad Engn Phys, Inst Mat, Mianyang, Peoples R China
[3] Aalborg Univ, Dept Energy Technol, Aalborg, Denmark
关键词
electric current control; switching convertors; power grids; predictive control; power harmonic filters; invertors; feedback; zero sequence; three-level T-type inverters; model predictive control strategy; system power rating; common DC-link; novel model predictive control based strategy; parallel operating 3LT; common-mode voltages; CMVs; neutral point potentials; paralleled; 3LT; potential exciting sources; MPC-based zero CMV method; cost function; closed-loop ZSCC feedback control method; MPC-based ZSCC elimination strategy; load current tracking; NPP balance control; GRID-CONNECTED INVERTERS; CONVERTERS; PWM; DESIGN;
D O I
10.1049/iet-pel.2018.5324
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The configuration of modular paralleled three-level T-type inverters (3LT(2)Is) has been widely utilised to extend the system power rating. However, zero sequence circulating currents (ZSCCs) are generated when sharing the common DC-link and the AC side without isolated transformers. This study presents a novel model predictive control (MPC) based strategy to eliminate the ZSCC in parallel operating 3LT(2)Is. Both the differences of common-mode voltages (CMVs) and neutral point potentials (NPPs) between paralleled 3LT(2)Is are investigated to be the potential exciting sources of the ZSCC based on the developed model of the ZSCC. According to this conclusion, an MPC-based zero CMV method which adds an additional term to the cost function is used to reduce the differences of CMVs between paralleled 3LT(2)Is. Besides, a closed-loop ZSCC feedback control method is further introduced to compensate the ZSCC by modifying the cost function. With the proposed MPC-based ZSCC elimination strategy, the ZSCC between the paralleled 3LT(2)Is can be effectively eliminated in both steady and dynamic states. Besides, good performances can be achieved for both load current tracking and NPP balance control. Simulation and experimental results validate the effectiveness of the proposed ZSCC elimination strategy.
引用
收藏
页码:2573 / 2581
页数:9
相关论文
共 50 条
  • [1] Multivector Model Predictive Current Control for Paralleled Three-Level T-Type Inverters With Circulating Current Elimination
    Liu, Tong
    Chen, Alian
    Huang, Yaopeng
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (08) : 8042 - 8052
  • [2] A Model Predictive Control Based Zero-Sequence Circulating Currents Elimination Algorithm For Parallel Operating Three-level T-type Inverters
    Wang, Xiaodong
    Zou, Jianxiao
    Li, Kai
    Dong, Zhenhua
    Zhang, Gang
    Chuan, Xie
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 583 - 588
  • [3] A Novel Model Predictive Control Strategy to Eliminate Zero-Sequence Circulating Current in Paralleled Three-Level Inverters
    Wang, Xiaodong
    Zou, Jianxiao
    Zhao, Jiancheng
    Xie, Chuan
    Li, Kai
    Munir, Hafiz Mudassir
    Guerrero, Josep M.
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2019, 7 (01) : 309 - 320
  • [4] Modeling and Suppression of Circulating Currents for Multi-Paralleled Three-Level T-Type Inverters
    Zhang, Zicheng
    Chen, Alian
    Xing, Xiangyang
    Li, Ke
    Du, Chunshui
    Zhang, Chenghui
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 708 - 713
  • [5] Modeling and Suppression of Circulating Currents for Multi-Paralleled Three-Level T-Type Inverters
    Chen, Alian
    Zhang, Zicheng
    Xing, Xiangyang
    Li, Ke
    Du, Chunshui
    Zhang, Chenghui
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (04) : 3978 - 3988
  • [6] Modeling and Elimination of Zero-Sequence Circulating Currents in Parallel Three-Level T-Type Grid-Connected Inverters
    Shao, Zhangping
    Zhang, Xing
    Wang, Fusheng
    Cao, Renxian
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (02) : 1050 - 1063
  • [7] Suppression of Circulating Currents for Paralleled Three-Level T-Type Inverters Under Unbalanced Operating Conditions
    Liu, Xi
    Liu, Tong
    Chen, Alian
    Xing, Xiangyang
    Zhang, Chenghui
    2020 THIRTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2020), 2020, : 3003 - 3007
  • [8] Zero-Sequence Circulating Current Suppression for Parallel T-Type Three-Level inverters
    Hu, Lucai
    Zhang, Jianzhong
    Xu, Shuai
    Wu, Haifu
    2019 IEEE 10TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG 2019), 2019, : 893 - 899
  • [9] Circulating currents control method for paralleled three-level NPC inverters
    Zorig, Abdelmalik
    Barkat, Said
    Rabhi, Abdelhamid
    Belkheiri, Mohammed
    ELECTRICAL ENGINEERING, 2024, : 7709 - 7718
  • [10] A Model Predictive Control based Fault-Tolerant Control Strategy for T-Type Three-Level Inverters
    Chen, Jie
    Chen, Alian
    Zhang, Chenghui
    Li, Ke