Validation of an isotope dilution gas chromatography-mass spectrometry method for combined analysis of oxysterols and oxyphytosterols in serum samples

被引:30
|
作者
Schoett, Hans-Frieder [1 ]
Luetjohann, Dieter [1 ]
机构
[1] Univ Clin Bonn, Inst Clin Chem & Clin Pharmacol, D-53105 Bonn, Germany
关键词
Oxycholesterol; Oxyphytosterols; Gas-chromatography-mass spectrometry; Hydroxycholesterol; Phytosterols; Oxidised plant sterols; CHOLESTEROL OXIDATION-PRODUCTS; CELLULAR LIPID-METABOLISM; OSBP-RELATED PROTEINS; HUMAN PLASMA; ENDOGENOUS MARKER; PLANT STEROL; BILE-ACIDS; 4-BETA-HYDROXYCHOLESTEROL; BRAIN; 24S-HYDROXYCHOLESTEROL;
D O I
10.1016/j.steroids.2015.02.006
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
We describe the validation of a method for the analysis of oxysterols, i.e. oxycholesterols and oxyphytosterols, in human serum using gas chromatography-mass spectrometry selected ion monitoring (GC-MS-SIM). Concentrations of 7 alpha- and 7 beta-hydroxy-, and 7oxo-cholesterol, -campesterol, and -sitosterol as well as 4 beta-hydroxycholesterol and side-chain oxygenated 24S-, 25-, and 27-hydroxycholesterol were determined by isotope dilution methodology. After saponification at room temperature the oxysterols were extracted, separated from their substrates, cholesterol, campesterol, and sitosterol, by solid phase extraction, and subsequently derivatised to their corresponding trimethylsilyl-ethers prior to GC-MS-SIM. In order to prevent artificial autoxidation butylated hydroxytoluene and ethylenediaminetetraacetic acid were added. The validation of the method was performed according to the International Conference on Harmonisation guidance, including limits of detection and quantification, ranges, recovery and precision. Due to improved instrumental settings and work-up procedure, limits of detection and quantification ranged between 8.0-202.0 pg/mL and 28.0-674 pg/mL, respectively. Recovery data in five calibration points varied between 91.9% and 116.8% and in serum samples between 93.1% and 118.1%. The mean coefficient of variation (CV) for the recovery of all compounds was <10%. Well satisfying CVs for within-day precision (2.1-10.8%) and for between-day precision (2.3-12.1%) were obtained. More than 20 samples could be processed in a single routine day and test series of about 300 samples can be realised without impairment of the validation parameters during a sequence. Comparison of oxysterol and oxyphytosterol content in serum and plasma revealed no difference. A fully validated isotope dilution methodology for the quantification of oxycholesterols and oxyphytosterols from human serum or plasma is presented. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:139 / 150
页数:12
相关论文
共 50 条
  • [1] Isotope-Dilution Gas Chromatography-Mass Spectrometry Method for the Analysis of Hydroxyurea
    Garg, Uttam
    Scott, David
    Frazee, Clint
    Kearns, Gregory
    Neville, Kathleen
    THERAPEUTIC DRUG MONITORING, 2015, 37 (03) : 325 - 330
  • [2] Validation of an isotope dilution gas chromatography-mass spectrometry method for analysis of 7-oxygenated campesterol and sitosterol in human serum
    Husche, Constanze
    Weingaertner, Oliver
    Pettersson, Hanna
    Vanmierlo, Tim
    Boehm, Michael
    Laufs, Ulrich
    Luetjohann, Dieter
    CHEMISTRY AND PHYSICS OF LIPIDS, 2011, 164 (06) : 425 - 431
  • [3] Validation of a method for the determination of plasma total homocysteine by gas chromatography-mass spectrometry with stable isotope dilution
    Belkhiria, MN
    Hammami, S
    Chraef, I
    Mahjoub, S
    Hammami, M
    EUROMEDLAB 2003: PROCEEDINGS OF THE 15TH IFCC-FESCC EUROPEAN CONGRESS OF CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, : 239 - 242
  • [4] Development of a Candidate Reference Measurement Procedure for the Analysis of Cortisol in Human Serum Samples by Isotope Dilution-Gas Chromatography-Mass Spectrometry
    Migaku Kawaguchi
    Akiko Takatsu
    Analytical Sciences, 2009, 25 : 989 - 992
  • [5] Development of a Candidate Reference Measurement Procedure for the Analysis of Cortisol in Human Serum Samples by Isotope Dilution-Gas Chromatography-Mass Spectrometry
    Kawaguchi, Migaku
    Takatsu, Akiko
    ANALYTICAL SCIENCES, 2009, 25 (08) : 989 - 992
  • [6] Validation of a gas chromatography-mass spectrometry method for the analysis of sterol oxidation products in serum
    Menendez-Carreno, Maria
    Garcia-Herreros, Cecilia
    Astiasaran, Iciar
    Ansorena, Diana
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 864 (1-2): : 61 - 68
  • [7] An isotope dilution headspace method with gas chromatography-mass spectrometry for determination of propylene oxide in food
    Cao, Xu-Liang
    Corriveau, Jeannette
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2009, 26 (04): : 482 - 486
  • [8] Measurement of salicylic acid in human serum using stable isotope dilution and gas chromatography-mass spectrometry
    Battezzati, A.
    Fiorillo, G.
    Spadafranca, A.
    Bertoli, S.
    Testolin, G.
    ANALYTICAL BIOCHEMISTRY, 2006, 354 (02) : 274 - 278
  • [9] Analytic validation of a gas chromatography-mass spectrometry method for quantification of six amino acids in canine serum samples
    Lopes, Rosana
    Gruetzner, Niels
    Berghoff, Nora
    Lidbury, Jonathan A.
    Suchodolski, Jan S.
    Steiner, Joerg M.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2015, 76 (12) : 1014 - 1021
  • [10] Rapid analysis of heterocyclic acetals in wine by stable isotope dilution gas chromatography-mass spectrometry
    Peterson, Ana L.
    Gambuti, Angelita
    Waterhouse, Andrew L.
    TETRAHEDRON, 2015, 71 (20) : 3032 - 3038