Comparing Surf Lifeguards and Nurse Anesthetists' Use of the i-gel Supraglottic Airway Device - An Observational Simulation Study

被引:0
|
作者
Norkjaer, Louise [1 ]
Staerk, Mathilde [1 ,2 ,3 ]
Lauridsen, Kasper G. [1 ,2 ,3 ]
Gallacher, Tabita K. [4 ]
Loyche, Jakob B. [5 ]
Krogh, Kristian [1 ,4 ]
Lofgren, Bo [1 ,3 ,6 ,7 ]
机构
[1] Aarhus Univ Hosp, Res Ctr Emergency Med, Aarhus, Denmark
[2] Randers Reg Hosp, Clin Res Unit, Randers, Denmark
[3] Randers Reg Hosp, Dept Internal Med, Skovlyvej 15, DK-8930 Randers, NE, Denmark
[4] Aarhus Univ Hosp, Dept Anesthesiol & Intens Care, Aarhus, Denmark
[5] Randers Reg Hosp, Dept Surg & Intens Care, Randers, Denmark
[6] Aarhus Univ Hosp, Dept Cardiol, Aarhus, Denmark
[7] Aarhus Univ, Inst Clin Med, Aarhus, Denmark
来源
关键词
cardiopulmonary resuscitation; drowning; ventilation; supraglottic airway; surf lifeguards; nurse anesthetists; RESUSCITATION COUNCIL GUIDELINES; BASIC LIFE-SUPPORT; BAG-VALVE-MASK; CARDIOPULMONARY-RESUSCITATION; CARDIAC-ARREST; VENTILATION; MANNEQUINS; INSERTION;
D O I
10.2147/OAEM.S239040
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: Using a supraglottic airway (SGA) may provide more effective ventilations compared with a mouth-to-pocket-mask for drowning victims. SGAs are widely used by nurse anesthetists but it is unknown whether surf lifeguards can use SGAs effectively. We aimed to compare the use of SGA by surf lifeguards and experienced nurse anesthetists. Materials and Methods: Surf lifeguards inserted a SGA (i-gel O-2, size 4) in a resuscitation manikin during cardiopulmonary resuscitation (CPR) and nurse anesthetists inserted a SGA in a resuscitation manikin placed on a bed, and performed ventilations. Outcome measures: time to first ventilation, tidal volume, proportion of ventilations with visible manikin chest rise, and ventilations within the recommended tidal volume (0.5-0.6 L). Results: Overall, 30 surf lifeguards and 30 nurse anesthetists participated. Median (Q1-Q3) time to first ventilation was 20 s (15-22) for surf lifeguards and 17 s (15-21) for nurse anesthetists (p=0.31). Mean (SD) tidal volume was 0.55 L (0.21) for surf lifeguards and 0.31 L (0.10) for nurse anesthetists (p<0.0001). Surf lifeguards and nurse anesthetists delivered 100% and 95% ventilations with visible manikin chest rise (p=0.004) and 19% and 5% ventilations within the recommended tidal volume, respectively (p<0.0001). Conclusion: In a simulated setting, there was no significant difference between surf lifeguards and experienced nurse anesthetists in time to first ventilation when using a SGA. Surf lifeguards delivered a higher tidal volume, and a higher proportion of ventilations within guideline recommendations, but generally ventilations caused visible manikin chest rise for both groups.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 50 条
  • [1] A Preliminary Study of I-Gel: A New Supraglottic Airway Device
    Kannaujia, Ashish
    Srivastava, Uma
    Saraswat, Namita
    Mishra, Abhijeet
    Kumar, Aditya
    Saxena, Surekha
    INDIAN JOURNAL OF ANAESTHESIA, 2009, 53 (01) : 52 - 56
  • [2] Nerve damage following the use of an i-gel supraglottic airway device
    Theron, A. D.
    Loyden, C.
    ANAESTHESIA, 2008, 63 (04) : 441 - 441
  • [3] A new single use supraglottic airway device with a noninflatable cuff and an esophageal vent: An observational study of ithe i-gel
    Richez, B.
    Saltel, L.
    Banchereau, F.
    Torrielli, R.
    Cros, A. M.
    ANESTHESIA AND ANALGESIA, 2008, 106 (04): : 1137 - 1139
  • [4] i-gel supraglottic airway in clinical practice: a prospective observational multicentre study
    Theiler, L.
    Gutzmann, M.
    Kleine-Brueggeney, M.
    Urwyler, N.
    Kaempfen, B.
    Greif, R.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (06) : 990 - 995
  • [5] I-GEL (Supraglottic Airway Device) in pediatric ophthalmic anesthesiology
    Rylov, Pavel
    Bersenev, Sergey
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 : 298 - 299
  • [6] Secure insertion of the i-gel supraglottic airway device in children A cohort study
    Sugiyama, Saori
    Yoshino, Jun
    Kinoshita, Hiroyuki
    Fujimura, Naoyuki
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (02) : 145 - 147
  • [7] The I-gel®, a single-use supraglottic airway device with a non-inflatable cuff and an esophageal vent: an observational study in children
    Beylacq, L.
    Bordes, M.
    Semjen, F.
    Cros, A. -M.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2009, 53 (03) : 376 - 379
  • [8] Supraglottic airway devices in short gynecological procedures: A randomized, clinical study comparing the Baska® mask and I-Gel® device
    Garg, Anurag
    Lamba, N. S.
    Chandra, N. S. Ajai
    Singhal, R. K.
    Chaudhary, Vishal
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2019, 8 (03) : 1134 - 1137
  • [9] Fibreoptic assessment of laryngeal positioning of the paediatric supraglottic airway device I-Gel
    Foucher-Lezla, Anne
    Lehousse, Thierry
    Monrigal, Jean P.
    Granry, Jean C.
    Beydon, Laurent
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2013, 30 (07) : 441 - 442
  • [10] TRACHEOTOMY GUIDED BY FIBEROPTIC BRONCHOSCOPY THROUGH AN I-GEL SUPRAGLOTTIC AIRWAY DEVICE
    Dominguez Garcia, D.
    Leon Sansegundo, T.
    Tejera Concepcion, R.
    Espinosa Dominguez, E.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2009, 56 (10): : 643 - 645