Model Calibration and Validation for the Fuzzy-EGARCH-ANN Model

被引:0
|
作者
Mohammed, Geleta T. [1 ]
Aduda, Jane A. [2 ]
Kube, Ananda O. [2 ]
机构
[1] Pan African Univ PAU, Dept Math, Nairobi 6200000200, Kenya
[2] Jomo Kenyatta Univ, Dept Math, Nairobi, Kenya
关键词
TIME-SERIES; VERIFICATION;
D O I
10.1155/2021/6637091
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This work shown as the fuzzy-EGARCH-ANN (fuzzy-exponential generalized autoregressive conditional heteroscedastic-artificial neural network) model does not require continuous model calibration if the corresponding DE algorithm is used appropriately, but other models such as GARCH, EGARCH, and EGARCH-ANN need continuous model calibration and validation so they fit the data and reality very well up to the desired accuracy. Also, a robust analysis of volatility forecasting of the daily S&P 500 data collected from Yahoo Finance for the daily spanning period 1/3/2006 to 20/2/2020. To our knowledge, this is the first study that focuses on the daily S&P 500 data using high-frequency data and the fuzzy-EGARCH-ANN econometric model. Finally, the research finds that the best performing model in terms of one-step-ahead forecasts based on realized volatility computed from the underlying daily data series is the fuzzy-EGARCH-ANN (1,1,2,1) model with Student's t-distribution.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Kurtosis of EGARCH model
    Li, Handong
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON FINANCIAL ENGINEERING AND RISK MANAGEMENT 2008, 2008, : 144 - 147
  • [2] On the multivariate EGARCH model
    Jane, Ten-Der
    Ding, Cherng G.
    APPLIED ECONOMICS LETTERS, 2009, 16 (17) : 1757 - 1761
  • [3] An evolutionary hybrid Fuzzy Computationally Efficient EGARCH model for volatility prediction
    Dash, Rajashree
    Dash, P. K.
    APPLIED SOFT COMPUTING, 2016, 45 : 40 - 60
  • [4] Model calibration by fuzzy-LP
    Tries, B
    LANDBAUFORSCHUNG VOLKENRODE, 1998, 48 (01): : 35 - 37
  • [5] ADAPT: MODEL USE, CALIBRATION, AND VALIDATION
    Gowda, P. H.
    Mulla, D. J.
    Desmond, E. D.
    Ward, A. D.
    Moriasi, D. N.
    TRANSACTIONS OF THE ASABE, 2012, 55 (04) : 1345 - 1352
  • [6] WEPP: MODEL USE, CALIBRATION, AND VALIDATION
    Flanagan, D. C.
    Frankenberger, J. R.
    Ascough, J. C., II
    TRANSACTIONS OF THE ASABE, 2012, 55 (04) : 1463 - 1477
  • [7] STANMOD: MODEL USE, CALIBRATION, AND VALIDATION
    van Genuchten, M. Th.
    Simunek, J.
    Leij, F. J.
    Toride, N.
    Sejna, M.
    TRANSACTIONS OF THE ASABE, 2012, 55 (04) : 1353 - 1366
  • [8] DRAINMOD: MODEL USE, CALIBRATION, AND VALIDATION
    Skaggs, R. W.
    Youssef, M. A.
    Chescheir, G. M.
    TRANSACTIONS OF THE ASABE, 2012, 55 (04) : 1509 - 1522
  • [9] Choosing the calibration model in assay validation
    Nagaraja, NV
    Paliwal, JK
    Gupta, RC
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (03) : 433 - 438
  • [10] HYDRUS: MODEL USE, CALIBRATION, AND VALIDATION
    Simunek, J.
    van Genuchten, M. Th.
    Sejna, M.