Monitoring the effects of heparin: evaluation of a new portable device

被引:1
|
作者
Cavanagh, SP
Haine, L
Ammori, B
Tate, G
Braithwaite, P
Gough, MJ
Homer-Vanniasinkam, S
机构
[1] Gen Infirm, Dept Vasc Surg, Leeds LS1 3EX, W Yorkshire, England
[2] Gen Infirm, Dept Haematol, Leeds LS1 3EX, W Yorkshire, England
[3] Gen Infirm, Dept Anaesthesia, Leeds LS1 3EX, W Yorkshire, England
来源
CARDIOVASCULAR SURGERY | 1998年 / 6卷 / 05期
关键词
heparin therapy; vascular surgery;
D O I
10.1016/S0967-2109(98)00012-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to measure the effects of heparin therapy in patients undergoing Vascular surgery, and to monitor the effectiveness of continuous intravenous heparin therapy in ward-based patients. In addition, we compared results from a new portable device with those from the standard laboratory assay. A prospective comparison of the two methods in patients undergoing peripheral vascular surgery, and in ward-based patients who were receiving intravenous heparin infusions was undertaken, Fifty patients who were undergoing vascular surgery and receiving a bolus dose of intravenous heparin, and 22 patients receiving a continuous heparin infusion, were recruited. Blood samples were taken 10 and 40 min following bolus heparin administration or after > 12h of a continuous heparin infusion. Plasma activated partial thromboplastin times (APTTp) measured by the haematology laboratory were compared with whole blood (APTT(B)) ascertained with the CoaguChek Plus Device (Boehringer Mannheim UK Diagnostics and Biochemicals Limited) at each time point. The results from the two methods were compared using the method of Bland and Altman (Lancet, 1986, 307-310). We found a good level of agreement between the two methods (at induction, mean bias was -0.050, limits of agreement -0.46-0.36: heparin infusions. mean bias was -0.283, limits of agreement -1.64-1.07). In addition we discovered that many of our patients appeared to be excessively anticoagulated during surgery (10 min following heparin bolus 47/50 patients had an APTT(B) > 150 s, 45/50 had an APTTp > 250 s; at 40 min 45/50 had an APTT(B) > 150 s, 39/50 had an APTTp > 250 s), In conclusion, whole blood APTT measurement allows rapid and accurate assessment of the effects of heparin therapy when compared with laboratory APTT measurement and may prevent both excessive and suboptimal anticoagulation. (C) 1998 The International Society for Cardiovascular Surgery. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:496 / 499
页数:4
相关论文
共 50 条
  • [1] Testing of a New Portable Device for Dynamic Bladder Pressure Monitoring
    Liu, Lingfeng
    Zhao, Kang
    Chen, Fan
    Wu, Jian
    Yang, Zhaofeng
    Chen, Ming
    Mao, Linbo
    Han, Jiurong
    LUTS-LOWER URINARY TRACT SYMPTOMS, 2018, 10 (02) : 193 - 197
  • [2] Portable bearing monitoring device
    不详
    ADVANCED MATERIALS & PROCESSES, 2006, 164 (12): : 10 - 10
  • [3] Design and initial evaluation of a portable in situ runoff and sediment monitoring device
    Sun, Tao
    Cruse, Richard M.
    Chen, Qiang
    Li, Hao
    Song, Chunyu
    Zhang, Xingyi
    JOURNAL OF HYDROLOGY, 2014, 519 : 1141 - 1148
  • [4] The pocketFerryBox - A new portable device for water quality monitoring in oceans and rivers
    Schroeder, F.
    Mizerkowski, B.
    Petersen, W.
    JOURNAL OF OPERATIONAL OCEANOGRAPHY, 2008, 1 (02) : 51 - 57
  • [5] Evaluation of a new portable device that measures diameter of animal fibres
    Quispe, E. C.
    Sacchero, D.
    Wuliji, T.
    Quispe, M. D.
    SOUTH AFRICAN JOURNAL OF ANIMAL SCIENCE, 2020, 50 (05) : 700 - 709
  • [6] Evaluation of a New Sonoclot Device for Heparin Management in Cardiac Surgery
    Dzemali, Omer
    Ganter, Michael T.
    Zientara, Alicja
    Graves, Kirk
    Behr, Renate
    Genoni, Michele
    Hofer, Christoph K.
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2017, 23 (01) : 20 - 26
  • [7] Evaluation of a low-cost portable NIRS device for monitoring muscle ischemia
    Marrero-Garcia, Ramses
    Cruz-Tabares, Yaiza
    Gonzalez-Cava, Jose M.
    Mendez-Perez, Juan Albino
    Reboso-Morales, Jose Antonio
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2024,
  • [8] Evaluation Of Obstructive Sleep Apnea Indices Using The Ares Portable Monitoring Device
    Cairns, A.
    Poulos, G.
    Bogan, R. K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [9] DOSE-RELATED EFFECTS OF CAFFEINE: SENSITIVITY OF A PORTABLE SLEEP MONITORING DEVICE
    Koshorek, J.
    Roth, T.
    Eklov, S.
    Kluck, S.
    Drake, C.
    SLEEP, 2012, 35 : A129 - A129
  • [10] The heparin management test: A new device for monitoring anticoagulation during coronary intervention
    Helft, G
    Bartolomeo, P
    Zaman, AG
    Worthley, SG
    Chokron, S
    Le Pailleur, C
    Beygui, F
    Le Feuvre, C
    Metzger, JP
    Vacheron, A
    Samama, MM
    THROMBOSIS RESEARCH, 1999, 96 (06) : 481 - 485