Identification of carbonylated peptides by tandem mass spectrometry using a precursor ion-like scan in negative ion mode

被引:27
|
作者
Bollineni, Ravi Ch [1 ]
Fedorova, Maria [1 ]
Hoffmann, Ralf [1 ]
机构
[1] Univ Leipzig, Fac Chem & Mineral, Ctr Biotechnol & Biomed, Inst Bioanalyt Chem, D-04103 Leipzig, Germany
关键词
Protein carbonylation; nUPLC-Orbitrap; Reactive oxygen species (ROS); 2,4-Dinitrophenylhydrazine (DNPH); Pulsed Q dissociation (PQD); AMINO-ACID-RESIDUES; METAL-CATALYZED OXIDATION; PROTEIN CARBONYLATION; CHEMICAL-IONIZATION; OXIDIZED PROTEINS; DISEASE; STRESS; CHROMATOGRAPHY; 2,4-DINITROPHENYLHYDRAZINE; FRAGMENTATION;
D O I
10.1016/j.jprot.2011.05.033
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reactive oxygen species (ROS) can oxidize proteins at almost any amino acid residue. Whereas some modifications are reversible within the cells, the higher oxidation states are especially irreversible. These irreversible post translational modifications are widely used as biomarkers of oxidative stress, such as protein carbonylation, which refers to aldehydes, ketones and lactams as 'reactive carbonyl groups'. This study relied on a set of synthetic peptides containing a C-terminal aldehyde (arginal) or modification with pyruvic acid (ketone) or 4-hydroxynonenal (aldehyde) at lysine or histidine residues, as well as peptides containing pyroglutamic acid (oxidation product of proline) and 2-amino-3-butyric acid (oxidation product of threonine). The carbonylation sites were specifically derivatized with 2,4-dinitrophenylhydrazine (DNPH) and the fragmentation behavior of the products investigated in electrospray ionization (ESI-) MS. Importantly, the DNPH-labeled carbonylated peptides showed favorable ionization behaviors in negative ion mode ESI providing a sensitive detection method. Regular peptides were mostly discriminated under these conditions. Among the fragmentation techniques tested for the negatively charged ions, pulsed Q dissociation provided three diagnostic ions at m/z values 152.0, 163.1 and 179.0, specific for DNPH-modified peptides. These marker ions were successfully applied to detect the carbonylated model peptides in a spiked tryptic digest of bovine serum albumin and a complex protein mixture obtained from HeLa cells. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2351 / 2359
页数:9
相关论文
共 50 条
  • [1] Dual negative precursor ion scan approach for rapid detection of glutathione conjugates using liquid chromatography/tandem mass spectrometry
    Mahajan, Mukesh K.
    Evans, Christopher A.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (07) : 1032 - 1040
  • [2] Protein identification using sequential ion/ion reactions and tandem mass spectrometry
    Coon, JJ
    Ueberheide, B
    Syka, JEP
    Dryhurst, DD
    Ausio, J
    Shabanowitz, J
    Hunt, DF
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (27) : 9463 - 9468
  • [3] Detection of arginine dimethylated peptides by parallel precursor ion scanning mass spectrometry in positive ion mode
    Rappsilber, J
    Friesen, WJ
    Paushkin, S
    Dreyfuss, G
    Mann, M
    ANALYTICAL CHEMISTRY, 2003, 75 (13) : 3107 - 3114
  • [4] Identification of a Chimera Mass Spectrum of Isomeric Lipid A Species Using Negative Ion Tandem Mass Spectrometry
    Dornyei, Agnes
    Kilar, Aniko
    Sandor, Viktor
    TOXINS, 2024, 16 (07)
  • [5] Enhanced Detection and Identification of Glycopeptides in Negative Ion Mode Mass Spectrometry
    Nwosu, Charles C.
    Strum, John S.
    An, Hyun Joo
    Lebrilla, Carlito B.
    ANALYTICAL CHEMISTRY, 2010, 82 (23) : 9654 - 9662
  • [6] Glycomics using negative ion tandem mass spectrometry of native glycans
    Zaia, J
    Seymour, JL
    Costello, CE
    GLYCOBIOLOGY, 2005, 15 (11) : 1209 - 1209
  • [7] Detection of tyrosine phosphorylated peptides by precursor ion scanning quadrupole TOF mass spectrometry in positive ion mode
    Steen, H
    Kuster, B
    Fernandez, M
    Pandey, A
    Mann, M
    ANALYTICAL CHEMISTRY, 2001, 73 (07) : 1440 - 1448
  • [8] Neutral loss and precursor ion scan tandem mass spectrometry for study of activated benzopyrene–DNA adducts
    D. Compagnone
    R. Curini
    G. D’Ascenzo
    M. Del Carlo
    C. Montesano
    S. Napoletano
    M. Sergi
    Analytical and Bioanalytical Chemistry, 2011, 401 : 1983 - 1991
  • [9] Rapid detection of cyanobacterial toxins in precursor ion mode by liquid chromatography tandem mass spectrometry
    Hiller, Susann
    Krock, Bernd
    Cembella, Allan
    Luckas, Bernd
    JOURNAL OF MASS SPECTROMETRY, 2007, 42 (09): : 1238 - 1250
  • [10] Complementary precursor ion and neutral loss scan mode tandem mass spectrometry for the analysis of glycerophosphatidylethanolamine lipids from whole rat retina
    Todd A. Lydic
    Julia V. Busik
    Walter J. Esselman
    Gavin E. Reid
    Analytical and Bioanalytical Chemistry, 2009, 394 : 267 - 275