Comparison of set-up control for head and neck patients between radiation oncologist and therapists with the aim of partial delegation

被引:5
|
作者
Garcia-Ramirez, M. [1 ]
Maugey, S. [1 ]
Burgaud, L. [1 ]
Carpentey, F. [1 ]
Parezys, E. [1 ]
Carricaburu, M. [1 ]
机构
[1] Hop Robert Boulin, Serv Radiotherapie, F-33505 Libourne, France
来源
CANCER RADIOTHERAPIE | 2014年 / 18卷 / 07期
关键词
Image-guided radiotherapy (IGRT); Patient positioning; Tasks sharing; Radiation therapists; RADIOTHERAPY; PROBABILITY;
D O I
10.1016/j.canrad.2014.04.010
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. The aim of this prospective study was to evaluate daily set-up by a radiation oncologist and by radiation therapists using on-board imaging of patients with head and neck cancer in order to calculate margin to PTV (planning target volume) and intent partial delegation of positioning images control. Patients and methods. The files of 11 patients with head and neck cancer treated on a Synergy (TM)(Elekta (TM)) accelerator with on-board imaging system were evaluated. Daily kV-kV images were doubleblind reviewed by radiation therapists (7 participants) and by one radiation oncologist. The radiation oncologist's measures were used for margin calculation from CTV to PTV. The difference of measures and the concordance of decisions between radiation therapists and the radiation oncologist were calculated. Results. The 325 measures made by the radiation oncologist resulted in a margin of 5 mm to be applied to the CTV in each direction. Nine hundred seventy-even measures were made by the radiation oncologist and radiation therapists with a difference of 3 mm or less in 98.46%. The concordance of decision for a 4 mm difference or less to the isocenter was 96.7%. Conclusion. - This study confirms the 5 mm PTV margin mostly used in ORL. The small gap between the radiation oncologist's and therapists' measures allows a partial delegation of positioning images control. 2014 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:655 / 658
页数:4
相关论文
共 35 条
  • [1] The evaluation of the set-up differences between radiation therapists for head and neck patients
    Kara, E.
    Yazici, A.
    Dirican, B.
    Boybas, B.
    Gunaydin, M. A.
    Kartal, A.
    Akmansu, M.
    Hicsonmez, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 122 : 37 - 38
  • [2] The Evaluation of the Set-Up Differences Between Radiation Therapists for Head and Neck Patients
    Kara, Esil
    Boybas, Burcu
    Gunaydin, Mustafa Ali
    Kartal, Arif
    Dirican, Bahar
    Akmansu, Muge
    Hicsonmez, Ayse
    [J]. TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2019, 34 (03): : 162 - 167
  • [3] Comparison of immobilisation, imaging and set-up errors during head and neck radiotherapy
    Hay, L.
    Devlin, L.
    Duffton, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S2044 - S2045
  • [4] A comparison of techniques for simulating set-up error and uncertainty in head and neck IMRT
    Ploquin, Nicolas
    Kay, Ian
    Rangel-Baltazar, Alejandra
    Lau, Harold
    Dunscombe, Peter
    [J]. MEDICAL PHYSICS, 2006, 33 (09) : 3213 - 3219
  • [5] Image Guidance Derived Set-up Errors for Head and Neck IMRT Patients
    Richmond, N.
    Pilling, K.
    Thompson, E.
    Walker, C.
    Dunlop, P.
    [J]. CLINICAL ONCOLOGY, 2011, 23 (03) : S50 - S51
  • [6] Prediction of Weight Loss, Tumor Response, and Set-Up Errors For Head and Neck Patients
    Seibert, R.
    Ramsey, C.
    Harris, C.
    Usynin, A.
    Robison, B.
    Neeley, M.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [7] Target Site Analysis of Set-up and Positioning Accuracy for Head and Neck Stereotactic Ablative Radiation Therapy (SABR)
    Mesko, S.
    Wang, H.
    Tung, S.
    Wang, C.
    Reddy, J.
    Garden, A. S.
    Phan, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S182 - S182
  • [8] Assessment of set-up errors in the radiotherapy of patients with head and neck cancer: standard vs. individual head support
    Androjna, Sabina
    Marcius, Valerija Zager
    Peterlin, Primoz
    Strojan, Primoz
    [J]. RADIOLOGY AND ONCOLOGY, 2020, 54 (03) : 364 - 370
  • [9] Intraoral stent reduces set-up errors in image guided radiotherapy for head and neck cancer patients
    Tarutani, K.
    Doi, H.
    Tanooka, M.
    Ishida, T.
    Kosaka, K.
    Ichimiya, K.
    Moridera, K.
    Kitajima, K.
    Yasuhiro, T.
    Fujiwara, M.
    Kishimoto, H.
    Kamikonya, N.
    [J]. EUROPEAN JOURNAL OF CANCER, 2017, 72 : S108 - S108
  • [10] COMPARISON OF SET-UP ERROR OF TWO STABILIZATION DEVICES IN HEAD & NECK IMRT AND EVALUATION OF IMAGE GUIDANCE STRATEGY
    Rolfo, M.
    Anderson, N.
    Khoo, V.
    Joon, D. Lim
    Wada, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S575 - S575