Dual-aptamer-based voltammetric biosensor for the Mycobacterium tuberculosis antigen MPT64 by using a gold electrode modified with a peroxidase loaded composite consisting of gold nanoparticles and a Zr(IV)/terephthalate metal-organic framework

被引:43
|
作者
Li, Ningning [1 ]
Huang, Xing [1 ]
Sun, Duanping [1 ,2 ]
Yu, Weiye [3 ]
Tan, Weiguo [3 ]
Luo, Zhaofan [4 ]
Chen, Zuanguang [1 ]
机构
[1] Sun Yat Sen Univ, Sch Pharmaceut Sci, Guangzhou 510006, Guangdong, Peoples R China
[2] Guangdong Pharmaceut Univ, Ctr Drug Res & Dev, Guangzhou 510006, Guangdong, Peoples R China
[3] Shenzhen Ctr Chron Dis Control, Shenzhen 518020, Peoples R China
[4] Sun Yat Sen Univ, Affiliated Hosp 7, Shenzhen 518071, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemical aptasensor; Mycobacterium tuberculosis; MPT64; UiO-66-NH2; Metal-organic framework; Horseradish peroxidase; ELECTROCHEMICAL DETECTION; AMPLIFICATION; APTASENSOR; DIAGNOSIS; GRAPHENE; PROTEIN; ASSAY;
D O I
10.1007/s00604-018-3081-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ultrasensitive aptasensor is described for the voltammetric determination of the Mycobacterium tuberculosis antigen MPT64 in human serum. Firstly, an amino-modified Zr(IV) based metal-organic framework (MOF; type UiO-66-NH2;made up from Zr6O32 units and 2-amino-terephthalate linkers) with a high specific surface was synthesized and used as the carrier of the gold nanoparticles and the aptamers. Then the signalling nanoprobe was fabricated after the horseradish peroxidase was cast on the nanomaterials. The two aptamers with synergistic effect on binding MPT64 were anchored on the gold electrode. Differential pulse voltammetry indicated that the peak current is highest if the ratio of the two aptamers is 1:1. The assay has a wide linear response range (0.02 to 1000pg mL( -1) of MPT64) and a 10fg mL( -1) detection limit at a working potential ofaround -96mV (vs Ag/AgCl). The results show this biosensor to be a viable tool for detection of tuberculosis atan early stage.
引用
收藏
页数:7
相关论文
共 11 条
  • [1] Dual-aptamer-based voltammetric biosensor for the Mycobacterium tuberculosis antigen MPT64 by using a gold electrode modified with a peroxidase loaded composite consisting of gold nanoparticles and a Zr(IV)/terephthalate metal-organic framework
    Ningning Li
    Xing Huang
    Duanping Sun
    Weiye Yu
    Weiguo Tan
    Zhaofan Luo
    Zuanguang Chen
    [J]. Microchimica Acta, 2018, 185
  • [2] Electrochemical Myoglobin Biosensor Based on Magnesium Metal-Organic Frameworks and Gold Nanoparticles Composite Modified Electrode
    Luo, Guiling
    Xie, Hui
    Niu, Yanyan
    Liu, Juan
    Huang, Yaqi
    Li, Binghang
    Li, Guangjiu
    Sun, Wei
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (03): : 2405 - 2413
  • [3] Aptamer based voltammetric biosensor for Mycobacterium tuberculosis antigen ESAT-6 using a nanohybrid material composed of reduced graphene oxide and a metal-organic framework
    Li, Linlin
    Yuan, Yonghua
    Chen, Yongjie
    Zhang, Pu
    Bai, Yan
    Bai, Lijuan
    [J]. MICROCHIMICA ACTA, 2018, 185 (08)
  • [4] Aptamer based voltammetric biosensor for Mycobacterium tuberculosis antigen ESAT-6 using a nanohybrid material composed of reduced graphene oxide and a metal-organic framework
    Linlin Li
    Yonghua Yuan
    Yongjie Chen
    Pu Zhang
    Yan Bai
    Lijuan Bai
    [J]. Microchimica Acta, 2018, 185
  • [5] Voltammetric immunoassay for Mycobacterium tuberculosis secretory protein MPT64 based on a synergistic amplification strategy using rolling circle amplification and a gold electrode modified with graphene oxide, Fe3O4 and Pt nanoparticles
    Gou, Dan
    Xie, Guoming
    Li, Yuxia
    Zhang, Xin
    Chen, Hui
    [J]. MICROCHIMICA ACTA, 2018, 185 (09)
  • [6] Voltammetric immunoassay for Mycobacterium tuberculosis secretory protein MPT64 based on a synergistic amplification strategy using rolling circle amplification and a gold electrode modified with graphene oxide, Fe3O4 and Pt nanoparticles
    Dan Gou
    Guoming Xie
    Yuxia Li
    Xin Zhang
    Hui Chen
    [J]. Microchimica Acta, 2018, 185
  • [7] Amperometric Sensing of Paracetamol Using a Glassy Carbon Electrode Modified with a Composite of Water-Stable Metal-Organic Framework and Gold Nanoparticles
    Shi, Yifei
    Zhang, Yubin
    Wang, Yang
    Huang, Huayu
    Ma, Junjie
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (08): : 7643 - 7654
  • [8] Electrochemical Probe of the Reduced Graphene Oxide Modified by Bare Gold Nanoparticles Functionalized Zr(IV)-based Metal-organic Framework for Detecting Nitrite
    Chen, Jing
    Li, Shuying
    Xu, Fanghong
    Zhang, Qian
    [J]. ELECTROANALYSIS, 2022, 34 (04) : 701 - 708
  • [9] Electrochemical determination of Salmonella typhimurium by using aptamer-loaded gold nanoparticles and a composite prepared from a metal-organic framework (type UiO-67) and graphene
    Ge Dai
    Zhi Li
    Feifei Luo
    Shiyun Ai
    Bo Chen
    Qingjiang Wang
    [J]. Microchimica Acta, 2019, 186
  • [10] Electrochemical determination of Salmonella typhimurium by using aptamer-loaded gold nanoparticles and a composite prepared from a metal-organic framework (type UiO-67) and graphene
    Dai, Ge
    Li, Zhi
    Luo, Feifei
    Ai, Shiyun
    Chen, Bo
    Wang, Qingjiang