A simple fluorescein derived colorimetric and fluorescent 'off-on' sensor for the detection of hypochlorite

被引:24
|
作者
Jin, Lei [1 ,2 ]
Xu, Mengyi [1 ]
Jiang, Hua [1 ]
Wang, Wenling [1 ]
Wang, Qingming [1 ]
机构
[1] Yancheng Teachers Univ, Sch Pharm, Jiangsu Prov Key Lab Coastal Wetland Bioresources, Yancheng 224051, Jiangsu, Peoples R China
[2] Nanjing Univ Technol, Coll Biotechnol & Pharmaceut Engn, Nanjing 210009, Jiangsu, Peoples R China
关键词
LIVING CELLS; SELECTIVE DETECTION; HYDROGEN-PEROXIDE; OXIDATIVE STRESS; AQUEOUS-SOLUTION; FAST-RESPONSE; PROBE; ACID; MYELOPEROXIDASE; WATER;
D O I
10.1039/c8ay01489b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, we have successfully provided a novel strategy to probe for ClO-. The strategy is based on a specific reaction promoted by ClO-: namely, hypochlorite oxidizes the amino group in probe 1 to an imine. Interestingly, in the presence of ClO-, a colorless solution of probe 1 turned pink with a maximum absorption band at 479 nm, and a 150-fold fluorescence enhancement at 553 nm was found. Probe 1 is highly selective to ClO- among other anions with a detection limit of 0.023 M. The membrane-permeable probe 1 was successfully demonstrated for monitoring ClO- in cultured HeLa cells. Therefore, probe 1 can be used for detection in practical samples. Probe 1 developed herein makes possible the use of organic complexes containing amines for designing fluorescence probes for ClO-.
引用
收藏
页码:4562 / 4569
页数:8
相关论文
共 50 条
  • [1] A novel colorimetric and OFF-ON fluorescent chemosensor based on fluorescein derivative for the detection of Fe3+ in aqueous solution and living cells
    Gao, Yan
    Liu, Huimin
    Liu, Qinglei
    Wang, Wei
    TETRAHEDRON LETTERS, 2016, 57 (17) : 1852 - 1855
  • [2] Reversible "OFF-ON" fluorescent and colorimetric sensor based benzothiazole-bisphenol A for fluoride in MeCN
    Erdemir, Serkan
    Kocyigit, Ozcan
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 900 - 905
  • [3] A simple benzildihydrazone derived colorimetric and fluorescent 'on-off-on' sensor for sequential detection of copper(II) and cyanide ions in aqueous solution
    Chandra, Rukmani
    Ghorai, Anupam
    Patra, Goutam K.
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 701 - 711
  • [4] "Off-on" aggregation-based fluorescent sensor for the detection of chloride in water
    Watt, Michelle M.
    Engle, Jeffrey M.
    Fairley, Kurtis C.
    Robitshek, Timothy E.
    Haley, Michael M.
    Johnson, Darren W.
    ORGANIC & BIOMOLECULAR CHEMISTRY, 2015, 13 (14) : 4266 - 4270
  • [5] A BODIPY-based "OFF-ON" fluorescent probe for fast and selective detection of hypochlorite in living cells
    Shi, Wen-Jing
    Huang, Yan
    Liu, Wancui
    Xu, Dan
    Chen, Shu-Ting
    Liu, Fenggang
    Hu, Jiaqin
    Zheng, Liyao
    Chen, Kun
    DYES AND PIGMENTS, 2019, 170
  • [6] A new off-on fluorescent sensor for the detection of Al(III) based on a chromone-derived Schiff-base
    Liu, Li-Mei
    Yang, Zheng-yin
    INORGANICA CHIMICA ACTA, 2018, 469 : 588 - 592
  • [7] Detection of Moisture by Fluorescent OFF-ON Sensor in Organic Solvents and Raw Food Products
    Kumar, Pawan
    Kaushik, Rahul
    Ghosh, Amrita
    Jose, D. Amilan
    ANALYTICAL CHEMISTRY, 2016, 88 (23) : 11314 - 11318
  • [8] A BODIPY-Diaminomaleonitrile Based Water-Soluble Fluorescent Probe for Selective "Off-On" Detection of Hypochlorite
    Leng, Junqiang
    Nie, Wen
    Yuan, Linying
    Liu, Shuang
    Liu, Tianxin
    Cheng, Jianbo
    Liu, Zhenbo
    CHEMISTRYSELECT, 2022, 7 (12):
  • [9] An acridone-derived fluorescent off-on probe for detection and in vivo imaging of nitroreductase
    Liu, Meicen
    Chen, Guanyu
    Xu, Lilan
    Chen, Tingting
    Chen, Wenqian
    Chen, Jinghua
    Zhang, Xi
    FRONTIERS IN MATERIALS, 2023, 10
  • [10] A novel colorimetric and off-on fluorescent sensor for Hg2+ and its application in live cell imaging
    Li, Man
    Jiang, Yuhua
    Zhang, Di
    Ding, Peigang
    Wang, Zhenji
    Ye, Yong
    Zhao, Yufen
    JOURNAL OF LUMINESCENCE, 2014, 148 : 219 - 224