Technique of percutaneous supraclavicular subclavian intra-aortic balloon pump placement

被引:5
|
作者
Song, Tae H. [1 ]
Jeevanandam, Valluvan [1 ]
机构
[1] Univ Chicago Med, Dept Surg, Sect Cardiac Surg, 5841 S Maryland Ave,E500A,MC5040, Chicago, IL 60637 USA
关键词
intra-aortic balloon pump; percutaneous; ambulatory; subclavian; axillary; SUPPORT; BRIDGE;
D O I
10.1016/j.xjtc.2021.03.039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:20 / 22
页数:3
相关论文
共 50 条
  • [1] Percutaneous Subclavian Intra-Aortic Balloon Pump: An Evolving Technique
    Wombacher, T.
    Juricek, C.
    Piech, R.
    Ota, T.
    Uriel, N.
    Jeevanandam, V.
    Song, T.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S438 - S438
  • [2] SUPRACLAVICULAR SUBCLAVIAN TECHNIQUE OF INTRA-AORTIC BALLOON INSERTION
    RUBENSTEIN, RB
    KARHADE, NV
    JOURNAL OF VASCULAR SURGERY, 1984, 1 (04) : 577 - 578
  • [3] Commentary: Staying put: Supraclavicular intra-aortic balloon pump placement
    Blanding, Walker M.
    Brocklebank, Paul
    Kilic, Arman
    JTCVS TECHNIQUES, 2021, 8 : 23 - 24
  • [4] Commentary: Percutaneous supraclavicular subclavian intra-aortic balloon pump insertion-A straighter route to fewer complications?
    Moroi, Morgan K.
    Takeda, Koji
    JTCVS TECHNIQUES, 2021, 8 : 25 - 26
  • [5] Subclavian Intra-Aortic Balloon Pump Placement Using Targeted Regional Anesthetic Blocks
    Griffiths, Keren
    Levy, Richard
    Lopez, Christopher Porras
    Wang, Aili
    ANESTHESIA AND ANALGESIA, 2023, 136 : 144 - 144
  • [6] Subclavian Intra-aortic Balloon Pump Placement Using Targeted Regional Anesthetic Blocks
    Shukla, Dip
    Flaherty, James
    Gorbaty, Benjamin
    Shaffer, Andrew
    Perry, Tjorvi
    Richardson, Stephen
    ANESTHESIA AND ANALGESIA, 2023, 136 : 143 - 143
  • [7] Unique Complications Associated With the Subclavian Intra-Aortic Balloon Pump
    Daubenspeck, Danisa
    Gonzalez, Laura S.
    Gerlach, Rebecca M.
    Chaney, Mark A.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (07) : 2212 - 2222
  • [8] A rare complication of intra-aortic balloon pump placement
    Varadarajan, B
    Karski, J
    Vegas, A
    Heinrich, L
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2005, 19 (02) : 259 - 260
  • [9] INTRA-OPERATIVE PLACEMENT OF THE PERCUTANEOUS INTRA-AORTIC BALLOON PUMP THROUGH THE ASCENDING AORTA
    MELVIN, KN
    GOLDMAN, BS
    ANNALS OF THORACIC SURGERY, 1982, 33 (06): : 636 - 637
  • [10] Intra-aortic balloon pump: is the technique really outdated?
    Akodad, Mariama
    Delmas, Clement
    Bonello, Laurent
    Duflos, Claire
    Roubille, Francois
    ESC HEART FAILURE, 2020, 7 (03): : 1025 - 1030