Interchangeability of macular thickness measurements between different volumetric protocols of Spectralis optical coherence tomography in normal eyes

被引:7
|
作者
Wenner, Yaroslava [1 ]
Wismann, Stephan [1 ]
Jaeger, Melanie [1 ]
Pons-Kuehnemann, Joern [2 ]
Lorenz, Birgit [1 ]
机构
[1] Univ Giessen, Dept Ophthalmol, Univ Klinikum Giessen & Marburg GmbH, D-35392 Giessen, Germany
[2] Univ Giessen, Inst Med Informat, Univ Klinikum Giessen & Marburg GmbH, D-35392 Giessen, Germany
关键词
Spectral domain optical coherence tomography; SD OCT; Protocol interchangeability; Scanning density; Retinal thickness; TIME-DOMAIN; RETINAL THICKNESS; REPRODUCIBILITY; REPEATABILITY; OCT;
D O I
10.1007/s00417-011-1630-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To evaluate in healthy eyes the interchangeability of retinal thickness measurements resulting from different protocols of Spectralis optical coherence tomography (OCT, Heidelberg Engineering, Germany). Three different central volumetric protocols were performed in one session by one single operator in a randomly selected eye of 31 healthy adults (range, 19-30 years): (1) area 6 x 6 mm, 25 scan pattern (SP), (2) area 6 x 6 mm, 49 SP, (3) area 6 x 3 mm, 97 SP. Nine ETDRS areas were analyzed, except outer areas for 97 SP. Interclass correlation coefficients (ICC) and limits of agreement (Bland-Altman) were calculated. Mean minimal foveal thickness was 224.0 +/- 15.8 mu m and central retinal thickness 280.8 +/- 16.5 mu m. ICC ranged from 0.973 to 0.993. Ninety-five percent limits of agreement between the protocols were < 7 mu m in all ETDRS areas. The difference between two measurements never exceeded 9 mu m. Spectralis OCT retinal thickness measurements in healthy subjects showed good protocol interchangeability for all tested protocols. Larger differences are to be expected in eyes with macular pathology.
引用
收藏
页码:1137 / 1145
页数:9
相关论文
共 50 条
  • [1] Interchangeability of macular thickness measurements between different volumetric protocols of Spectralis optical coherence tomography in normal eyes
    Yaroslava Wenner
    Stephan Wismann
    Melanie Jäger
    Jörn Pons-Kühnemann
    Birgit Lorenz
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 1137 - 1145
  • [2] Repeatability in and interchangeability between the macular and the fast macular thickness map protocols: a study on normal eyes with Stratus optical coherence tomography
    Eriksson, Urban
    Alm, Albert
    [J]. ACTA OPHTHALMOLOGICA, 2009, 87 (07) : 725 - 730
  • [3] Reproducibility of retinal thickness measurements in eyes with uveitic macular oedema using Spectralis optical coherence tomography
    Iannetti, Ludovico
    Pesci, Francesca Romana
    Spinucci, Giovanni
    Abdulaziz, Randa
    Pivetti-Pezzi, Paola
    [J]. ACTA OPHTHALMOLOGICA, 2012, 90 (06) : e490 - e491
  • [4] Macular thickness measurements in normal eyes using spectral domain optical coherence tomography
    Legarreta, John E.
    Gregori, Giovanni
    Punjabi, Omar S.
    Knighton, Robert W.
    Lalwani, Geeta A.
    Puliafito, Carmen A.
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2008, 39 (04) : S43 - S49
  • [5] Normal macular thickness measurements in healthy eyes using stratus optical coherence tomography
    Chan, A
    Duker, JS
    Ko, TH
    Fujimoto, JG
    Schuman, JS
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (02) : 193 - 198
  • [6] Repeatability of Retinal Macular Thickness Measurements in Patients with Clinically Significant Macular Edema Using Two Different Scanning Protocols of Spectralis Optical Coherence Tomography
    Fiore, Tito
    Lupidi, Marco
    Androudi, Sofia
    Giansanti, Fabrizio
    Fruttini, Daniela
    Cagini, Carlo
    [J]. OPHTHALMOLOGICA, 2015, 234 (03) : 167 - 171
  • [7] Comparison of Retinal Thickness in Normal Eyes Using Stratus and Spectralis Optical Coherence Tomography
    Grover, Sandeep
    Murthy, Ravi K.
    Brar, Vikram S.
    Chalam, Kakarla V.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (05) : 2644 - 2647
  • [8] CENTRAL MACULAR THICKNESS MEASUREMENTS IN YOUNG ADULTS MEASURED BY SPECTRALIS OPTICAL COHERENCE TOMOGRAPHY
    Tan, Alexander
    Chen, Fred
    Forward, Hannah
    Mountain, Jenny
    Newnham, John
    Pennell, Craig
    Mackey, David
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 : 71 - 71
  • [9] Macular thickness and macular volume measurements using spectral domain optical coherence tomography in normal Nepalese eyes
    Pokharel, Amrit
    Shrestha, Gauri Shankar
    Shrestha, Jyoti Baba
    [J]. CLINICAL OPHTHALMOLOGY, 2016, 10 : 511 - 519
  • [10] Macular Thickness Measurements in Healthy Eyes Using Six Different Optical Coherence Tomography Instruments
    Wolf-Schnurrbusch, Ute E. K.
    Ceklic, Lala
    Brinkmann, Christian K.
    Iliev, Milko E.
    Frey, Manuel
    Rothenbuehler, Simon P.
    Enzmann, Volker
    Wolf, Sebastian
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (07) : 3432 - 3437