Integration of three-dimensional left atrial magnetic resonance images into a real-time electroanatomic mapping system: Validation of a registration method

被引:33
|
作者
Bertaglia, Emanuele [1 ]
Brandolino, Glauco [1 ]
Zoppo, Franco [1 ]
Zerbo, Francesca [1 ]
Pascotto, Pietro [1 ]
机构
[1] Osped Civile Mirano, Dipartimento Cardiol, Venice, Italy
来源
关键词
atrial fibrillation; catheter ablation; magnetic resonance imaging;
D O I
10.1111/j.1540-8159.2008.00986.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The alignment of three-dimensional (3D) left atrial images acquired by magnetic resonance (MR) with the anatomical information yielded by 3D mapping systems is one of the most critical issues in image integration techniques for catheter ablation of atrial fibrillation (AF). We assessed the accuracy of a simplified method of superimposing 3D MR left atrial images on real-time left atrial electroanatomic maps (registration). Methods: MR data on the left atrium in 40 patients with drug-refractory AF were imported into the CartoMerge (TM) (Biosense Webster, Inc., Diamond Bar, CA, USA) electroanatomic mapping system. Registration was obtained by combining "visual alignment" of one endocardial point and "surface registration" of a limited number of points sampled on the posterior wall of the left atrium. The accuracy of the registration process was assessed through a statistical algorithm incorporated into the CartoMerge (TM) system, and through the percentage of pulmonary veins (PVs) in which electrical isolation was achieved after anatomical ablation. Results: The mean registration surface-to-point distance and ablation surface-to-point distance were 1.33 +/- 0.96 mm and 1.47 +/- 1.15 mm, respectively. Upon completion of the circumferential anatomical ablation around the PVs, electrical PV isolation was confirmed by a multipolar circular mapping catheter in 129 of 146 PVs (89%). Conclusions: Our registration method, which is mainly based on the surface registration of the posterior wall of the left atrium, enables almost 90% of PVs to be isolated by means of an anatomically based catheter ablation approach.
引用
收藏
页码:273 / 282
页数:10
相关论文
共 50 条
  • [1] Integration of three-dimensional left atrial magnetic resonance image into real-time electroanatomic mapping system: Validation of a new registration method to guide catheter ablation of atrial fibrillation
    Brancolino, G.
    Zoppo, F.
    Zerbo, F.
    Pascotto, P.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 : S33 - S34
  • [2] Real-Time Three-Dimensional Image Integration in Atrial Fibrillation Ablation: A Randomised Comparison with an Electroanatomic Mapping System
    Kriatselis, Charalampos
    Min, Tang
    Roser, Mattias
    Gerds-Li, Hong
    Fleck, Eckert
    [J]. CIRCULATION, 2008, 118 (18) : S587 - S588
  • [3] Novel method to integrate three-dimensional computed tomographic images of the left atrium with real-time electroanatomic mapping
    Verma, A
    Marrouche, N
    Natale, A
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (08) : 968 - 968
  • [5] Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations
    Dong, J
    Calkins, H
    Solomon, SB
    Lai, SH
    Dalal, D
    Lardo, A
    Brem, E
    Preiss, A
    Berger, RD
    Halperin, H
    Dickfeld, T
    [J]. CIRCULATION, 2006, 113 (02) : 186 - 194
  • [6] Ablation of mitral isthmus-dependent atrial flutter using integration of real-time electroanatomic mapping with three-dimensional computed tomography
    Dukkipati, S
    Holmvang, G
    Ruskin, J
    Mansour, M
    [J]. HEART RHYTHM, 2006, 3 (01) : 124 - 124
  • [7] Real-time three-dimensional echocardiographic quantification of regional left ventricular function: Validation by magnetic resonance imaging
    Corsi, C
    Sugeng, L
    Nasser, HJ
    Weinert, L
    Niel, J
    Ebner, C
    Steringer-Mascherbauer, R
    Schmidt, F
    Schummers, G
    Lang, RM
    Mor-Avi, V
    [J]. CIRCULATION, 2005, 112 (17) : U649 - U649
  • [8] Validation of real-time three-dimensional echocardiographic measurements of left ventricular ejection fraction with magnetic resonance imaging
    Sugeng, L
    MacEneaney, P
    Weinert, L
    Koch, R
    Mahia, P
    Bednarz, JE
    Furlong, KT
    Collins, KA
    Mor-Avi, V
    Lang, RM
    [J]. CIRCULATION, 2003, 108 (17) : 338 - 338
  • [9] Real-time representation of multielectrode ablation catheters by integration of computed tomographic geometry with three-dimensional electroanatomic mapping of left atrium and pulmonary veins
    Merino, Jose L.
    Refoyo, Elena
    Peinado, Rafael
    Cuesta, Emilio
    [J]. HEART RHYTHM, 2008, 5 (04) : 628 - 629
  • [10] Left atrial volume by real-time three-dimensional echocardiography: Validation by multidetector computed tomography
    Miyasaka, Yoko
    Haiden, Mio
    Aota, Yasuko
    Takada, Atsuaki
    Sato, Yuji
    Kubota, Yuichi
    Oshi, Chihiro
    Kimura, Yutaka
    Takehana, Kazuya
    Iwasaka, Toshiji
    [J]. CIRCULATION, 2007, 116 (16) : 328 - 328