A Novel Bioreactor for Stimulating Skeletal Muscle In Vitro

被引:2
|
作者
Donnelly, Kenneth [1 ,2 ]
Khodabukus, Alastair [2 ]
Philp, Andrew [2 ]
Deldicque, Louise [2 ]
Dennis, Robert G. [3 ,4 ]
Baar, Keith [2 ]
机构
[1] Univ Dundee, Div Mech Engn & Mechatron, Dundee, Scotland
[2] Univ Dundee, Div Mol Physiol, Dundee, Scotland
[3] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC USA
[4] Univ N Carolina, Curriculum Appl Sci & Engn, Chapel Hill, NC USA
基金
英国工程与自然科学研究理事会; 英国生物技术与生命科学研究理事会;
关键词
ELECTRICAL-STIMULATION; IMPLANTABLE DEVICE; DENERVATED MUSCLES; C2C12; MYOTUBES; EXCITABILITY; CULTURES; TISSUE; EXPRESSION; RESPONSES; FATIGUE;
D O I
10.1089/ten.tec.2009.0125
中图分类号
Q813 [细胞工程];
学科分类号
摘要
For over 300 years, scientists have understood that stimulation, in the form of an electrical impulse, is required for normal muscle function. More recently, the role of specific parameters of the electrical impulse (i.e., the pulse amplitude, pulse width, and work-to-rest ratio) has become better appreciated. However, most existing bioreactor systems do not permit sufficient control over these parameters. Therefore, the aim of the current study was to engineer an inexpensive muscle electrical stimulation bioreactor to apply physiologically relevant electrical stimulation patterns to tissue-engineered muscles and monolayers in culture. A low-powered microcontroller and a DC-DC converter were used to power a pulse circuit that converted a 4.5 V input to outputs of up to 50 V, with pulse widths from 0.05 to 4 ms, and frequencies up to 100 Hz (with certain operational limitations). When two-dimensional cultures were stimulated at high frequencies (100 Hz), this resulted in an increase in the rate of protein synthesis (at 12 h, control [CTL] = 5.0 +/- 0.16; 10 Hz 5.0 +/- 0.07; and 100 Hz 5.5 +/- 0.13 fmol/min/mg) showing that this was an anabolic signal. When three-dimensional engineered muscles were stimulated at 0.1 ms and one or two times rheobase, stimulation improved force production (CTL = 0.07 +/- 0.009; 1.25V/mm = 0.10 +/- 0.011; 2.5V/mm = 0.14146 +/- 0.012; and 5V/mm = 0.03756 +/- 0.008kN/mm(2)) and excitability (CTL = 0.53 +/- 0.022; 1.25V/mm = 0.44 +/- 0.025; 2.5V/mm = 0.41 +/- 0.012; and 5V/mm = 0.60 +/- 0.021V/mm), suggesting enhanced maturation. Together, these data show that the physiology and function of muscles can be improved in vitro using a bioreactor that allows the control of pulse amplitude, pulse width, pulse frequency, and work-to-rest ratio.
引用
收藏
页码:711 / 718
页数:8
相关论文
共 50 条
  • [1] 3D bioprinting of skeletal muscle constructs with different bioink and the use of bioreactor for stimulating
    Calero, F. J.
    CRYOLETTERS, 2020, 41 (03) : 162 - 162
  • [2] Engineering skeletal muscle tissue in bioreactor systems
    An Yang
    Li Dong
    中华医学杂志(英文版), 2014, (23) : 4130 - 4139
  • [3] Engineering skeletal muscle tissue in bioreactor systems
    An Yang
    Li Dong
    CHINESE MEDICAL JOURNAL, 2014, 127 (23) : 4130 - 4139
  • [4] A novel in vitro three-dimensional skeletal muscle model
    Michele L. Marquette
    Diane Byerly
    Marguerite Sognier
    In Vitro Cellular & Developmental Biology - Animal, 2007, 43 : 255 - 263
  • [5] Novel In Vitro Exercise Model of Engineered Human Skeletal Muscle
    Madden, L.
    Jackman, C.
    Wang, J.
    Kraus, W.
    Truskey, G.
    Bursac, N.
    TISSUE ENGINEERING PART A, 2015, 21 : S46 - S46
  • [6] A novel in vitro three-dimensional skeletal muscle model
    Marquette, Michele L.
    Byerly, Diane
    Sognier, Marguerite
    IN VITRO CELLULAR & DEVELOPMENTAL BIOLOGY-ANIMAL, 2007, 43 (07) : 255 - 263
  • [7] Functional enhancement of bioreactor assisted engineered skeletal muscle
    Zare, Shirin
    Christ, George
    Moon, Du Geon
    Zhao, Weixin
    Atala, Anthony
    Yoo, James J.
    FASEB JOURNAL, 2007, 21 (05): : A135 - A135
  • [8] Functional enhancement of bioreactor assisted engineered skeletal muscle
    Zare, S.
    Christ, G.
    Moon, D. G.
    Zhao, W.
    Atala, A.
    Yoo, J. J.
    TISSUE ENGINEERING, 2007, 13 (07): : 1698 - 1698
  • [9] Bioreactor Preconditioning for Tissue Engineered Skeletal Muscle Repair
    Christ, G.
    TISSUE ENGINEERING PART A, 2015, 21 : S14 - S14
  • [10] A Novel Flow Bioreactor for In Vitro Microvascularization
    Lee, Eun Jung
    Niklason, Laura E.
    TISSUE ENGINEERING PART C-METHODS, 2010, 16 (05) : 1191 - 1200