Optimal load-shedding using local information

被引:0
|
作者
Fujita, G
Shirai, G
机构
关键词
power generation outage; load-shedding; optimization; quadratic programming; power flow calculation; under-frequency relay;
D O I
10.1002/eej.4391160204
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes an optimal load-shedding policy based on quadratic programming using only some power system state variables after severe generation outages. When generation outage is severe, the imbalance between supply and demand causes a declining frequency. Utilities generators cannot be operated excessively at frequencies above normal. Some of the load must be shed to prevent system damage. Optimal load-shedding policies have been studied using all state variables of the power system. However, in real power system operations, it is difficult to obtain remote information in that fraction of a second following generation outages. An optimal load-shedding method is constructed in this research using quadratic programming (QP) under the assumption that all power system state variables can be available. However, these state variables cannot be easily accessible (as already mentioned). A suboptimal load-shedding scheme based on the local state variables is then studied. The proposed load-shedding method is based on the aforementioned optimal one. The change in line-power flows and the amount of generation power outage are used as accessible data at each load point. Incorporating this local information into the optimal load-shedding method based on the QP method, the proposed load-shedding method is established here. The effectiveness of this proposed method is illustrated by two examples and simulation results on a model power system show that the method is encouraging.
引用
收藏
页码:32 / 51
页数:20
相关论文
共 50 条
  • [1] Optimal load-shedding using local information
    Hosei Univ
    [J]. Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 1996, 116 (02): : 32 - 51
  • [2] Local optimal load-shedding with allowance for voltage deviation
    Fujita, G
    Shirai, G
    [J]. ELECTRICAL ENGINEERING IN JAPAN, 1997, 119 (01) : 35 - 44
  • [3] New autonomous load-shedding scheme based on local information
    Fujita, G
    Yokoyama, R
    Takeuchi, S
    Shirai, G
    [J]. CONTROL OF POWER SYSTEMS AND POWER PLANTS 1997 (CPSPP'97), 1998, : 459 - 464
  • [4] Optimal Load-Shedding Control of a Microgrid Power System
    Madiba, T.
    Bansal, Ramesh C.
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2018, 46 (07) : 768 - 787
  • [5] Comprehensive Load-Shedding System
    Jethwa, Uchhrang K.
    Bansal, Rajeev Kumar
    Date, Ninad
    Vaishnav, Ranjeet
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (02) : 740 - 749
  • [6] Load-shedding in Kitwe, Zambia: Effects and implications on household and local economies
    Umar, Bridget Bwalya
    Chisola, Moses N.
    Mushili, Beverly M.
    Kunda-Wamuwi, Chibuye Florence
    Kafwamba, David
    Membele, Garikai
    Imasiku, Eunice N. S.
    [J]. DEVELOPMENT SOUTHERN AFRICA, 2022, 39 (03) : 354 - 371
  • [7] SIMULATION OF 5 LOAD-SHEDDING SCHEDULES
    DURBECK, RC
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (05): : 959 - &
  • [8] Chaotic slime mould optimization algorithm for optimal load-shedding in distribution system
    Abid, Md. Shadman
    Apon, Hasan Jamil
    Ahmed, Ashik
    Morshed, Khandaker Adil
    [J]. AIN SHAMS ENGINEERING JOURNAL, 2022, 13 (04)
  • [9] New Local Adaptive Load-shedding Methods to Mitigate Power System Blackouts
    Saffarian, A.
    Sanaye-Pasand, M.
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2012, 40 (03) : 348 - 368
  • [10] CONSIDERATIONS WHEN PLANNING A LOAD-SHEDDING PROGRAM
    HARRISON, P