Development and Interlaboratory Validation of a Simple Screening Method for Genetically Modified Maize Using a ΔΔCq-Based Multiplex Real-Time PCR Assay

被引:13
|
作者
Noguchi, Akio [1 ]
Nakamura, Kosuke [1 ]
Sakata, Kozue [1 ]
Sato-Fukuda, Nozomi [1 ]
Ishigaki, Takumi [1 ]
Mano, Junichi [2 ]
Takabatake, Reona [2 ]
Kitta, Kazumi [2 ]
Teshima, Reiko [1 ]
Kondo, Kazunari [1 ]
Nishimaki-Mogami, Tomoko [1 ]
机构
[1] Natl Inst Hlth Sci, Setagaya Ku, 1-18-1 Kamiyoga, Tokyo 1588501, Japan
[2] Natl Agr & Food Res Org, Natl Food Res Inst, 2-1-12 Kannondai, Tsukuba, Ibaraki 3058642, Japan
关键词
MODIFIED ORGANISMS; FOOD-PRODUCTS; QUANTIFICATION; SAMPLES;
D O I
10.1021/acs.analchem.5b04335
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A number of genetically modified (GM) maize events have been developed and approved worldwide for commercial cultivation. A screening method is needed to monitor GM maize approved for commercialization in countries that mandate the labeling of foods containing a specified threshold level of GM crops. In Japan, a screening method has been implemented to monitor approved GM maize since 2001. However, the screening method currently used in Japan is time-consuming and requires generation of a calibration curve and experimental conversion factor (C-f) value. We developed a simple screening method that avoids the need for a calibration curve and C-f value. In this method, Delta C-q values between the target sequences and the endogenous gene are calculated using multiplex real-time PCR, and the Delta Delta C-q value between the analytical and control samples is used as the criterion for determining analytical samples in which the GM organism content is below the threshold level for labeling of GM crops. An interlaboratory study indicated that the method is applicable independently with at least two models of PCR instruments used in this study.
引用
收藏
页码:4285 / 4293
页数:9
相关论文
共 50 条
  • [1] Development and validation of a multiplex real-time PCR method for screening genetically modified plants
    Weidner, Christopher
    Koppel, Rene
    Freyer, Regina
    Richl, Petra
    Lieske, Kathrin
    Mankertz, Joachim
    Waiblinger, Hans-Ulrich
    JOURNAL OF CONSUMER PROTECTION AND FOOD SAFETY, 2024, 19 (02) : 165 - 174
  • [2] Development of Quantitative Duplex Real-Time PCR Method for Screening Analysis of Genetically Modified Maize
    Oguchi, Taichi
    Onishi, Mari
    Minegishi, Yasutaka
    Kurosawa, Yasunori
    Kasahara, Masaki
    Akiyama, Hiroshi
    Teshima, Reiko
    Futo, Satoshi
    Furui, Satoshi
    Hino, Akihiro
    Kitta, Kazumi
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2009, 50 (03): : 117 - 125
  • [3] Inter laboratory Validation of Quantitative Duplex Real-Time PCR Method for Screening Analysis of Genetically Modified Maize
    Takabatake, Reona
    Koiwa, Tomohiro
    Kasahara, Masaki
    Takashima, Kaori
    Futo, Satoshi
    Minegishi, Yasutaka
    Akiyama, Hiroshi
    Teshima, Reiko
    Oguchi, Taichi
    Mano, Junichi
    Furui, Satoshi
    Kitta, Kazumi
    FOOD HYGIENE AND SAFETY SCIENCE, 2011, 52 (04): : 265 - 269
  • [4] Development of a qualitative, multiplex real-time PCR kit for screening of genetically modified organisms (GMOs)
    Doerries, Hans-Henno
    Remus, Ivonne
    Groenewald, Astrid
    Groenewald, Cordt
    Berghof-Jaeger, Kornelia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (06) : 2043 - 2054
  • [5] Development of a qualitative, multiplex real-time PCR kit for screening of genetically modified organisms (GMOs)
    Hans-Henno Dörries
    Ivonne Remus
    Astrid Grönewald
    Cordt Grönewald
    Kornelia Berghof-Jäger
    Analytical and Bioanalytical Chemistry, 2010, 396 : 2043 - 2054
  • [6] Development and validation of a multiplex real-time PCR method to simultaneously detect 47 targets for the identification of genetically modified organisms
    Cottenet, Geoffrey
    Blancpain, Carine
    Sonnard, Veronique
    Chuah, Poh Fong
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (21) : 6831 - 6844
  • [7] Development and Validation of a New Robust Detection Method for Low-Content DNA Using ??Cq-Based Real-Time PCR with Standard Plasmids as a Control br
    Soga, Keisuke
    Nakamura, Kosuke
    Egi, Tomohiro
    Narushima, Jumpei
    Yoshiba, Satoko
    Kishine, Masahiro
    Mano, Junichi
    Kitta, Kazumi
    Takabatake, Reona
    Shibata, Norihito
    Kondo, Kazunari
    ANALYTICAL CHEMISTRY, 2022, 94 (41) : 14475 - 14483
  • [8] Development and validation of a multiplex real-time PCR method to simultaneously detect 47 targets for the identification of genetically modified organisms
    Geoffrey Cottenet
    Carine Blancpain
    Véronique Sonnard
    Poh Fong Chuah
    Analytical and Bioanalytical Chemistry, 2013, 405 : 6831 - 6844
  • [9] Development of two screening duplex PCR assays for genetically modified organism quantification using multiplex real-time PCR master mixes
    Pansiot, Julien
    Chaouachi, Maher
    Cavellini, Laetitia
    Romaniuk, Marcel
    Ayadi, Mira
    Bertheau, Yves
    Laval, Valerie
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2011, 232 (02) : 327 - 334
  • [10] Development of two screening duplex PCR assays for genetically modified organism quantification using multiplex real-time PCR master mixes
    Julien Pansiot
    Maher Chaouachi
    Laetitia Cavellini
    Marcel Romaniuk
    Mira Ayadi
    Yves Bertheau
    Valérie Laval
    European Food Research and Technology, 2011, 232 : 327 - 334