Manufacture of red cells in additive solution from whole blood refrigerated for 5 days or remanufactured from red cells stored in plasma

被引:2
|
作者
Wiltshire, Michael [1 ]
Cardigan, Rebecca [1 ]
Thomas, Stephen [1 ]
机构
[1] NHS Blood & Transplant, Components Dev Lab, Brentwood CM15 8DP, Essex, England
关键词
red cell concentrates; red cell quality; red cell storage; remanufacture; CREUTZFELDT-JAKOB-DISEASE; STORAGE; TRANSFUSION; ADENINE; CPD; 2,3-DIPHOSPHOGLYCERATE; TRANSMISSION; SURVIVAL; QUALITY; VCJD;
D O I
10.1111/j.1365-3148.2010.01024.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Methods and Materials: Ten RCC in SAG-M were produced following the remanufacture of red cells in CPD plasma on day 5/6 or after 5 days hold as leucodepleted CPD whole blood. In addition, 10 RCC in CPD plasma and 9 in CPDA-1 plasma were stored without further processing. Units were assessed for red cell parameters including haemolysis, adenosine triphosphate (ATP), 2,3-diphosphoglycerate (2,3-DPG) and extracellular potassium. Results: Units in SAG-M produced by remanufacture of RCC in plasma or by delayed manufacture of whole blood had comparable levels of haemolysis, ATP and 2,3-DPG. Furthermore, these units underwent biochemical changes similar to reference SAG-M units, with the exception of haemolysis which was greater at the end of shelf life and supernatant potassium which was lower following remanufacture. As expected, the decline in ATP was greater in red cells stored in CPD plasma compared with CPDA-1 plasma. In general, units in CPD plasma were of similar quality at day 28 compared to those in CPDA-1 plasma at day 35. Conclusions: RCC produced following the remanufacture of RCC in plasma or the delayed manufacture of whole blood are of acceptable in vitro quality and should be assigned the same shelf life as standard RCC in SAG-M.
引用
收藏
页码:383 / 391
页数:9
相关论文
共 50 条
  • [1] In vitro evaluation of red cells stored up to 56 days in a new additive solution
    Dumont, L. J.
    Herschel, L. H.
    Roger, J.
    Dumont, D. F.
    Champeny, W.
    Aubuchon, J. P.
    Zia, M.
    Kandler, R.
    TRANSFUSION, 2007, 47 (03) : 92A - 92A
  • [2] Metabolic effects of radiation on red blood cells from cold stored whole blood
    Becerra, Sandra C.
    Christy, Barbara A.
    Herzig, Maryanne C.
    Bynum, James A.
    Darlington, Daniel N.
    TRANSFUSION, 2023, 63 : S199 - S207
  • [3] HEMOLYSIS AND SUBLETHAL INJURY IN RED BLOOD CELLS STORED IN A NOVEL ADDITIVE SOLUTION
    Harm, S. K.
    Radwanski, K.
    Min, K.
    Yazer, M. H.
    VOX SANGUINIS, 2013, 105 : 153 - 153
  • [4] Citrate metabolism in red blood cells stored in additive solution-3
    D'Alessandro, Angelo
    Nemkov, Travis
    Yoshida, Tatsuro
    Bordbar, Aarash
    Palsson, Bernhard O.
    Hansen, Kirk C.
    TRANSFUSION, 2017, 57 (02) : 325 - 336
  • [5] Plasma from stored packed red blood cells (PRBCs) and whole blood (WB) activates human pulmonary endothelial cells (EC).
    Silliman, CC
    Elzi, DJ
    Hiester, AA
    Tamura, DY
    BLOOD, 1998, 92 (10) : 138B - 138B
  • [6] Red Cell Concentrates from Whole Blood Stored at 4°C for 7 Days
    Strandenes, G.
    Hervig, T. A.
    Olsnes, C.
    Lunde, T. F.
    TRANSFUSION, 2016, 56 : 51A - 51A
  • [7] Evaluation of canine red blood cells stored in a saline, adenine, and glucose solution for 35 days
    Wardrop, KJ
    Tucker, RL
    Mugnai, K
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 1997, 11 (01): : 5 - 8
  • [8] The effects of polyvinyl chloride and polyolefin blood bags on red blood cells stored in a new additive solution
    Hill, HR
    Oliver, CK
    Lippert, LE
    Greenwalt, TJ
    Hess, JR
    VOX SANGUINIS, 2001, 81 (03) : 161 - 166
  • [9] In vitro Assessment of Red Blood Cells Stored with Minimal Plasma in a New Additive Solution and Non-DEHP Container
    Radwanski, K.
    Min, K.
    TRANSFUSION, 2009, 49 : 37A - 37A
  • [10] Influence of Whole Blood Processing on MicroRNA levels in Red Blood Cells (RBCs) Stored in two Additive Solutions
    Thibault, L.
    Cayer, M.
    Girard, M.
    TRANSFUSION, 2014, 54 : 42A - 42A