Experiment on critical heat flux of subcooled flow boiling in compound heat transfer tubes

被引:9
|
作者
Liu, P. [1 ,2 ,7 ]
Guo, Y. S. [1 ,2 ,7 ]
Zheng, W. L. [1 ,2 ,7 ]
Song, Y. T. [2 ,4 ,7 ]
Peng, X. B. [4 ]
Tang, M. Y. [1 ,5 ]
Wang, W. H. [3 ]
Huang, S. F. [1 ,2 ,6 ]
Ji, J. D. [1 ,2 ,7 ]
Chen, Q. H. [1 ,2 ,7 ]
Mao, X. [4 ]
机构
[1] Anhui Univ Sci & Technol, State Key Lab Min Response & Disaster Prevent & C, Huainan 232001, Peoples R China
[2] Anhui Univ Sci & Technol, Sch Mech Engn, Huainan 232001, Peoples R China
[3] Anhui Univ, Inst Phys & Informat Technol, Hefei 230061, Peoples R China
[4] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
[5] Anhui Univ Sci & Technol, Sch Min & Safety Engn, Huainan 232001, Peoples R China
[6] Nanjing Univ Aeronaut & Astronaut, Jiangsu Key Lab Precis & Micromfg Technol, Nanjing 210016, Peoples R China
[7] Anhui Univ Sci & Technol, Anhui Key Lab Mine Intelligent Equipment & Techno, Huainan 232001, Peoples R China
基金
中国国家自然科学基金;
关键词
Departure from nucleate boiling; Critical heat flux; Compound heat transfer tubes; Subcooled boiling; Correlations; TWISTED TAPE INSERT; PRESSURE-DROP; WATER-FLOW; TRANSFER ENHANCEMENT; CIRCULAR TUBES; RIBBED TUBE; AUGMENTATION; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2021.117556
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to enhance the Departure from Nucleate Boiling (DNB) type critical heat flux (CHF) of the divertor in International Thermonuclear Experimental Reactor (ITER), the novel compound heat transfer tube (CHTT) was proposed as a compound CHF enhancement technique by inserting a twisted tape into an internal thread tube (ITT). Firstly, the experiments were investigated for subcooled water flow boiling on four kinds of cooling tubes, including plain tube (PT), tube with twisted tape inserts (TWTT), ITT and CHTT, covering system pressures from 0.2 to 0.8 MPa, inlet temperatures from 25 to 65 celcius, mass fluxes from 543 to 2935 kg/m(2) s and heat fluxes from 1 to 17 MW/m(2). The experimental results showed that the CHTT combined by using the twisted tape inserts and internal thread tube performed better in enhancing the subcooled CHF than the individual technique. The values of CHF in CHTT could be improved by 33.19%, 55.14% and 130.71%, respectively, compared with that of the TWTT, ITT and PT, respectively. Secondly, the effect of twist ratio, pitch, mass flux and pressure on CHF were also analyzed in CHTT. The CHF was directly proportional to the pitch, mass flux and pressure and inversely proportional to the twist ratio. Finally, the five existing subcooled CHF correlations were evaluated based on the present experimental data in CHTT. It was found that the Tong-75-II correlation showed the best prediction accuracy with a mean absolute error (MAE) of 32.80% and a root mean square error (RMSE) of 33.72%.
引用
收藏
页数:14
相关论文
共 50 条