Experimental and numerical assessment of EPS wind action on long span transmission line conductors

被引:19
|
作者
Paluch, M. J.
Cappellari, T. T. O. [1 ]
Riera, J. D.
机构
[1] Univ Fed Rio Grande do Sul, PPGEC, LDEC, Porto Alegre, RS, Brazil
[2] Univ Passo Fundo, PPGE, Passo Fundo, RS, Brazil
关键词
transmission line; wind action; extended pressure system (EPS); numerical model;
D O I
10.1016/j.jweia.2006.09.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper presents a thorough evaluation of the action of extended pressure system (EPS) winds on a long spar transmission line crossing of a water way, which was monitored during a period of about a year for the determination of its fluctuating response. Additionally, a numerical model and ensuing analysis of the cable crossing subjected to stationary turbulent wind is presented and compared with the experimental observations. In fact, the former serve to complement the experimental findings by supplying information that could not be directly measured in the field. The latter, in turn, constitute a confirmation of the Monte Carlo full simulation analysis of the cable crossing, which includes a 3D model of the structural system as well as a 3D model of the stationary wind field. Out important result of the studies is that full three-dimensional models of both the cable crossing and the wind fields are needed to correctly evaluate the structural response. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:473 / 492
页数:20
相关论文
共 50 条
  • [1] The free vibration of long-span transmission line conductors with dampers
    Wang, HQ
    Miao, JC
    Luo, JH
    Huang, F
    Wang, LG
    JOURNAL OF SOUND AND VIBRATION, 1997, 208 (04) : 501 - 516
  • [2] Large amplitude vibrations of long-span transmission lines with bundled conductors in gusty wind
    Pham Viet Hung
    Yamaguchi, Hiroki
    Isozaki, Masanori
    Gull, Jawad Hussain
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2014, 126 : 48 - 59
  • [3] Wind tunnel test on aeroelastic model of long span transmission line system
    Guo, Yong
    Sun, Bing-Nan
    Ye, Yin
    Shen, Guo-Hui
    Lou, Wen-Juan
    2007, Zhejiang University Press, 20 Yugu Road, Hangzhou, 310027, China (41):
  • [4] Numerical analysis on wind-induced vibration response of long-span transmission tower-line system
    Li, Xianxin
    Ding, Binghao
    Qi, Daokun
    Zhang, Kaixin
    Wang, Miaomiao
    GRADEVINAR, 2024, 76 (09): : 829 - 838
  • [5] Experimental Study on Rain-Wind-Induced Vibration of Overhead Transmission Line Conductors
    Bi, Wenzhe
    Tian, Li
    Dong, Xu
    Wang, Jiawei
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2024,
  • [6] Wind tunnel investigation on wind-induced vibration control of long span transmission line systems
    Deng, Hong-Zhou
    Zhu, Song-Ye
    Su, Su
    Wang, Zhao-Min
    Tongji Daxue Xuebao/Journal of Tongji University, 2003, 31 (09): : 1009 - 1013
  • [7] Behaviour of transmission line conductors under tornado wind
    Hamada, Ahmed
    El Damatty, Ashraf A.
    WIND AND STRUCTURES, 2016, 22 (03) : 369 - 391
  • [8] The response of long span bridges to wind action
    Wardlaw, RL
    PROBABILISTIC MECHANICS & STRUCTURAL RELIABILITY: PROCEEDINGS OF THE SEVENTH SPECIALTY CONFERENCE, 1996, : 66 - 69
  • [9] Assessment of code recommendations through simulation of EPS wind loads along a segment of a transmission line
    Fadel Miguel, Leticia Fleck
    Fade Miguel, Leandro Fleck
    Riera, Jorge Daniel
    Kaminski, Joao, Jr.
    Ramos de Menezes, Ruy Carlos
    ENGINEERING STRUCTURES, 2012, 43 : 1 - 11
  • [10] Numerical simulation and experimental study on wind characteristics of long span bridge in mountainous area
    Zhou, Ji
    Wang, Xinguo
    Liu, Zhiwen
    Chen, Xiangyan
    Journal of Railway Science and Engineering, 2022, 19 (04) : 995 - 1003