ON THE ESTIMATION OF RIGID-BODY TRANSFORMATION FOR TLS REGISTRATION

被引:0
|
作者
Scaioni, Marco [1 ]
机构
[1] Tongji Univ, Coll Surveying & Geoinformat, Ctr Spatial Informat Sci & Sustainable Dev Applic, Shanghai 200092, Peoples R China
来源
关键词
Geo-referencing; Least Squares; Monte Carlo method; Reliability Analysis; Terrestrial Laser Scanning; ORIENTATION; MODELS;
D O I
暂无
中图分类号
P9 [自然地理学];
学科分类号
0705 ; 070501 ;
摘要
The paper presents some considerations on the estimation of rigid-body transformation which is the basis for registration and geo-referencing in terrestrial laser scanning. Two main issues are afforded, which in the opinion of the author have been poorly investigated up until now. The first one concerns the analysis of the stochastic model of Least Squares estimation of the transformation. In standard practice, the control points used for parameter estimation are considered as equally precise. Here two different approaches for weighting observations in laser scan and ground control points are proposed and evaluated through a set of Monte Carlo simulations. The second aspect refers to the reliability analysis. In particular the estimation of a joint-adjustment including both geo-referencing parameters and geodetic network observations for the determination of ground control points is discussed and evaluated.
引用
收藏
页码:601 / 606
页数:6
相关论文
共 50 条
  • [1] Estimation of Rigid-Body Registration Quality Using Registration Networks
    Datteri, Ryan
    Dawant, Benoit M.
    [J]. MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [2] A molecular viewer for the analysis of TLS rigid-body motion in macromolecules
    Painter, J
    Merritt, EA
    [J]. ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2005, 61 : 465 - 471
  • [3] RIGID-BODY MOTION IN CRYSTALS - APPLICATION OF CONSTRAINTS ON TLS MODEL
    RAE, AD
    [J]. ACTA CRYSTALLOGRAPHICA SECTION A, 1975, 31 (SEP1): : 570 - 574
  • [4] Evaluating intraoperative rigid-body registration with the AWIGS system
    Knoop, H
    Raczkowsky, J
    Wyslucha, U
    Flegele, T
    Wörn, H
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1310 - 1310
  • [5] A PROCEDURE FOR DETERMINING RIGID-BODY TRANSFORMATION PARAMETERS
    CHALLIS, JH
    [J]. JOURNAL OF BIOMECHANICS, 1995, 28 (06) : 733 - 737
  • [6] Linear approximation method for weighted rigid-body registration
    Wu, Liao
    Yang, Xiangdong
    Xu, Jing
    Miao, Dongjing
    Chen, Ken
    [J]. Qinghua Daxue Xuebao/Journal of Tsinghua University, 2013, 53 (10): : 1424 - 1428
  • [7] Distribution of Fiducial Registration Error in Rigid-Body Point-Based Registration
    Moghari, Mehdi Hedjazi
    Abolmaesumi, Purang
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (11) : 1791 - 1801
  • [8] The distribution of target registration error in rigid-body, point-based registration
    West, JB
    Fitzpatrick, JM
    [J]. INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 1999, 1613 : 460 - 465
  • [9] The distribution of target registration error in rigid-body point-based registration
    Fitzpatrick, JM
    West, JB
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (09) : 917 - 927
  • [10] Derivation of expected registration error for point-based rigid-body registration
    Fitzpatrick, JM
    West, JB
    Maurer, CR
    [J]. MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 16 - 27