Intraoperative Conversion to Five-Strand Hamstring Autograft Configuration Significantly Increases Anterior Cruciate Ligament Graft Diameter Independent of Patient Characteristics

被引:8
|
作者
Walczak, Brian E. [1 ]
Hetzel, Scott J. [2 ]
Akoh, Craig Chike [1 ]
Baer, Geoffrey S. [1 ]
机构
[1] Univ Wisconsin Madison, Dept Orthoped & Rehabil, 1685 Highland Ave, Madison, WI 53792 USA
[2] Univ Wisconsin Madison, Dept Biostat & Med Informat, Madison, WI USA
关键词
ACL reconstruction; hamstring autograft; graft diameter; ACL failure; FAILURE RATES; RECONSTRUCTION; ALLOGRAFT; REVISION; PREDICTORS; SIZE; RISK; OUTCOMES; KNEE;
D O I
10.1055/s-0039-3400955
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Intraoperative conversion of a four-strand hamstring autograft to a five-strand configuration during an anterior cruciate ligament (ACL) reconstruction has been reported. However, the expected change in graft size and the dependence on patient characteristics are currently not well described. The purpose of this study was to determine the effective change in hamstring graft diameter and reliance on patient characteristics when intraoperatively converting a four-strand hamstring autograft into a five-strand configuration during an ACL reconstruction. A prospective, paired cohort study design was used to measure individual hamstring autograft diameter intraoperatively using traditional four-strand configuration followed by a five-strand configuration. All hamstring tendons included were long enough to consider a five-strand configuration. Five-strand hamstring autograft increased graft diameter in all patients. Hamstring tendon graft diameter increased by an average of 0.99mm (95% confidence interval [CI]: 0.84-1.11) in the five-strand configuration compared with the traditional four-strand configuration (mean: 7.8mm). There was no significant difference in the average increase in graft diameter between males (1.04mm) and females (0.92mm) ( p =0.323). Eighty-three percent (95% CI: 57.8-95.6) of average graft diameters <= 8mm in the four-strand configuration achieved an average graft diameter of >8mm in the five-strand configuration, and 70% (95% CI: 35.4- 91.9) of four-strand configuration average diameters<8mm achieved an average graft diameter>8.0mm in the five-strand configuration. Five-strand hamstring autograft reliably increased intraoperative hamstring tendon autograft diameter, with an average of 1mm, compared with traditional four-strand configuration. This increase in diameter is independent of sex and remained significant when controlling for age, laterality, body mass index, and semitendinosus length.
引用
收藏
页码:828 / 833
页数:6
相关论文
共 26 条
  • [1] Five-Strand Hamstring Autograft for Anterior Cruciate Ligament Reconstruction
    Lavery, Kyle P.
    Rasmussen, Jeffrey F.
    Dhawan, Aman
    ARTHROSCOPY TECHNIQUES, 2014, 3 (04): : E423 - E426
  • [2] Five-Strand Hamstring Autograft in Primary Anterior Cruciate Ligament Reconstruction
    Krishna, Lingaraj
    Tan, Xin Yang
    Thangaraja, Acksen
    Wong, Francis K. L.
    JOURNAL OF KNEE SURGERY, 2019, 32 (04) : 366 - 371
  • [3] Five-Strand Hamstring Autografts for Anterior Cruciate Ligament Reconstruction: A Systematic Review
    Smith, John-Rudolph H.
    Houck, Darby A.
    Hart, Jessica A.
    Vidal, Armando F.
    Frank, Rachel M.
    Bravman, Jonathan T.
    McCarty, Eric C.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2019, 7 (02)
  • [4] Five-Strand versus Four-Strand Hamstring Tendon Graft Technique for Anterior Cruciate Ligament Reconstruction: A Biomechanical Comparison
    Vaillant, Eric R.
    Parks, Brent G.
    Camire, Lyn M.
    Hinton, Richard Y.
    JOURNAL OF KNEE SURGERY, 2017, 30 (09) : 916 - 919
  • [5] Influence of graft diameter on patient reported outcomes after hamstring autograft anterior cruciate ligament reconstruction
    Duerr, Robert A.
    Garvey, Kirsten D.
    Ackermann, Jakob
    Matzkin, Elizabeth G.
    ORTHOPEDIC REVIEWS, 2019, 11 (03) : 129 - 133
  • [6] Five-Strand Hamstring Autograft Versus Quadruple Hamstring Autograft With Graft Diameters 8.0 Millimeters or More in Anterior Cruciate Ligament Reconstruction: Clinical Outcomes With a Minimum 2-Year Follow-Up
    Calvo, Rafael
    Figueroa, David
    Figueroa, Francisco
    Vaisman, Alex
    Schmidt-Hebbel, Andres
    Morales, Nelson
    Izquierdo, Guillermo
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (05):
  • [7] A 5-Strand Hamstring Autograft Achieves Outcomes Comparable to Those of a 4-Strand Hamstring Autograft With a Graft Diameter of 8 mm or More in Anterior Cruciate Ligament Reconstruction
    Krishna, Lingaraj
    Tan, Xin Yang
    Wong, Francis Keng Lin
    Toh, Shi Jie
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2018, 6 (03):
  • [8] Relationship between graft failure following anterior cruciate ligament reconstruction and hamstring autograft diameter
    Ates, O.
    Bozkurt, I.
    Uluyardimci, E.
    Ocguder, D. A.
    Ugurlu, M.
    ACTA ORTHOPAEDICA BELGICA, 2023, 89 (03): : 429 - 433
  • [9] Knee kinematics in anatomic anterior cruciate ligament reconstruction with four- and five-strand hamstring tendon autografts
    Sideris, Anders
    Hamze, Ali
    Bertollo, Nicky
    Broe, David
    Walsh, William
    ORTHOPEDIC REVIEWS, 2018, 10 (03) : 89 - 96
  • [10] Five-Strand Versus Four-Strand Hamstring Autografts in Anterior Cruciate Ligament Reconstruction-A Prospective Randomized Controlled Study
    Krishna, Lingaraj
    Chan, Chloe Xiaoyun
    Lokaiah, Lakshmipathi
    Chinnasamy, Duraimurugan
    Goyal, Saumitra
    Wang, Mingchang
    Singh, Amritpal
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2021, 37 (02): : 579 - 585