Trans-Catheter Closure of Patent Ductus Arteriosus-What Is the Best Device?

被引:40
|
作者
Ghasemi, Abdolrahim [2 ]
Pandya, Swati [1 ]
Reddy, Surendranath Veeram [1 ]
Turner, Daniel R. [1 ]
Du, Wei [1 ]
Navabi, Mohamad Ali [3 ]
Mirzaaghayan, Mohammad Reza [3 ]
Kiani, Abdolrazagh [3 ]
Sloan, Katherine [1 ]
Forbes, Thomas J. [1 ]
机构
[1] Childrens Hosp Michigan, Detroit Med Ctr, Div Pediat Cardiol, Detroit, MI 48201 USA
[2] Shaheed Behshti Univ Med Sci, Modarres Hosp, Dept Pediat Cardiol & Cardiac Surg, Tehran, Iran
[3] Univ Tehran Med Sci, Imam Hosp, Dept Pediat Cardiol & Cardiac Surg, Tehran, Iran
基金
中国国家自然科学基金;
关键词
gianturco coil; flipper coil; amplatzer duct occluder; nit-occlud coil; TRANSCATHETER CLOSURE; PERCUTANEOUS CLOSURE; GIANTURCO COILS; OCCLUSION; IMMEDIATE; TRIAL; MM;
D O I
10.1002/ccd.22393
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Over the past three decades, transcatheter occlusion of patent ductus arteriosus (PDA) has evolved to be the procedure of choice. Gianturco and Flipper coils are the most commonly used coils in the United States for closure of small and moderate size PDAs. For larger PDAs, interventionalists in the United States commonly use the Amplatzer Duct Occluder (ADO) and those in Europe use the ADO or the Nit-Occlud Coils (NOC). A comparison between Gianturco coils, Flipper coils, ADO, and NOC has never been made. Objective: To compare the success and complication rate associated with the four different devices used for transcatheter closure of PDA. Success was defined as complete closure of PDA with absence of a residual shunt (R.S.) at six months follow-up. Methods: Two institutions collaborated in combining their data to evaluate the results of transcatheter closure of PDA. Results: Totally, 546 patients underwent successful PDA occlusion at both institutions. Gianturco and Flipper coils were used in 120 (22%) and 119 (22%) patients respectively. A total of 152 (28%) patients received ADO and 155 (28%) patients received NOC. Immediate R.S. were noted in 226 (41.4%) patients in the entire study group with the NOC group having the highest percentage of R.S. (80/155, 51.6%, P = 0.004). Of the 484 patients with follow-up echocardiograms at 6 months, 35 (7.2%) patients had persistent R.S. The NOC (3/143, 2.1%) and ADO (5/150, 3.3%) groups had the least R.S. at six months follow-up. Conclusion: Per our definition of success, the Nit-Occlud coils and the Amplatzer duct-occluder devices had significantly higher success rate for PDA occlusion versus the coils. (c) 2010 Wiley-Liss, Inc.
引用
收藏
页码:687 / 695
页数:9
相关论文
共 50 条
  • [1] ECHOCARDIOGRAPHIC GUIDANCE FOR TRANS-CATHETER DEVICE CLOSURE OF PATENT DUCTUS ARTERIOSUS IN EXTREMELY LOW BIRTH WEIGHT INFANTS
    Paudel, Govinda
    Philip, Ranjit
    Zurakowski, David
    Balduf, Kaitlin
    Fahnhorst, Sarah
    Waller, Benjamin
    Sathanandam, Shyam
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 576 - 576
  • [2] Early Clinical Experience of Trans-catheter Closure of Patent Ductus Arteriosus in Extremely Premature Neonates
    Philip, Ranjit
    Sathanandam, Shyam
    Balduf, Kaitlin
    Washington, Kristin
    Dereddy, Narendra
    Chilakala, Sandeep
    Arevalo, Alejandro
    Waller, B. Rush
    [J]. PEDIATRICS, 2018, 141
  • [3] Early Clinical Experience of Trans-Catheter Closure of Patent Ductus Arteriosus in Extremely Premature Neonates
    Philip, Ranjit
    Balduf, Kaitlin
    Washington, Kristin
    Chilakala, Sandeep
    Arevalo, Alejandro
    Fagan, Thomas
    Waller, B. Rush
    Sathanandam, Shyam
    [J]. CIRCULATION, 2016, 134
  • [4] Validation Study of Intra-Cardiac Echocardiography in Trans-Catheter Closure of Patent Ductus Arteriosus
    Yoshimoto, Hironaga
    Suda, Kenji
    Maeda, Yasuto
    Kagiyama, Hiroyuki
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B759 - B759
  • [5] TRANS-CATHETER CLOSURE OF PATENT DUCTUS ARTERIOSUS IN SEVERELY PREMATURE NEONATES: A NEW TECHNIQUE FOR A VEXING PROBLEM
    Peck, D.
    Zahn, E.
    Garg, R.
    Phillips, A.
    McRae, M.
    Simmons, C.
    Nevin, P.
    Basacker, K.
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2016, 64 (01) : 140 - 140
  • [6] TRANS-CATHETER CLOSURE OF PATENT DUCTUS ARTERIOSUS IN SEVERELY PREMATURE NEONATES: A NEW TECHNIQUE FOR A VEXING PROBLEM
    Peck, Daniel
    Garg, Ruchira
    McRae, Marion
    Nevin, Phillip
    Basaker, Kaylan
    Phillips, Alistair
    Simmons, Charles
    Zahn, Evan
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 995 - 995
  • [7] TRANS-CATHETER CLOSURE OF PATENT DUCTUS ARTERIOSUS IN SEVERELY PREMATURE NEONATES: IS POST-LIGATION SYNDROME AN ISSUE?
    Peck, D.
    Garg, R.
    Phillips, A.
    Mcrae, M.
    Nevin, P.
    Basacker, K.
    Simmons, C.
    Zahn, E.
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2016, 64 (01) : 239 - 239
  • [8] What is the optimal device for closure of a persistently patent ductus arteriosus?
    Forbes, Thomas J.
    Turner, Daniel R.
    [J]. PROGRESS IN PEDIATRIC CARDIOLOGY, 2012, 33 (02) : 125 - 129
  • [9] PROTRUSION OF THE DEVICE - A COMPLICATION OF CATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS
    OTTENKAMP, J
    HESS, J
    TALSMA, MD
    BUISLIEM, TN
    [J]. BRITISH HEART JOURNAL, 1992, 68 (03): : 301 - 303
  • [10] Device Closure of Patent Ductus Arteriosus in Adults
    O'Byrne, Michael L.
    Smith, Christopher L.
    Gillespie, Matthew J.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2020, 36 (06) : 795 - 796