Scanning reflection ion microscopy in a helium ion microscope

被引:5
|
作者
Petrov, Yuri V. [1 ]
Vyvenko, Oleg F. [2 ]
机构
[1] St Petersburg State Univ, Interdisciplinary Resource Ctr Nanotechnol, St Petersburg 198504, Russia
[2] St Petersburg State Univ, Fac Phys, St Petersburg 198504, Russia
来源
关键词
helium ion microscope; low-angle ion scattering; reflection microscopy; surface imaging; surface morphology; ELECTRON-MICROSCOPY; CONTRAST; SURFACE; DIFFRACTION; IMAGE;
D O I
10.3762/bjnano.6.114
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Reflection ion microscopy (RIM) is a technique that uses a low angle of incidence and scattered ions to form an image of the specimen surface. This paper reports on the development of the instrumentation and the analysis of the capabilities and limitations of the scanning RIM in a helium ion microscope (HIM). The reflected ions were detected by their "conversion" to secondary electrons on a platinum surface. An angle of incidence in the range 5-10 degrees was used in the experimental setup. It was shown that the RIM image contrast was determined mostly by surface morphology but not by the atomic composition. A simple geometrical analysis of the reflection process was performed together with a Monte Carlo simulation of the angular dependence of the reflected ion yield. An interpretation of the RIM image formation and a quantification of the height of the surface steps were performed. The minimum detectable step height was found to be approximately 5 nm. RIM imaging of an insulator surface without the need for charge compensation was successfully demonstrated.
引用
收藏
页码:1125 / 1137
页数:13
相关论文
共 50 条
  • [1] Scanning Helium Ion Microscopy
    Hill, Ray
    Notte, John A.
    Scipioni, Larry
    ADVANCES IN IMAGING AND ELECTRON PHYSICS, VOL 170, 2012, 170 : 65 - 148
  • [2] Scanning Helium Ion Microscope: Distribution of Secondary Electrons and Ion Channeling
    Petrov, Yu. V.
    Vyvenko, O. F.
    Bondarenko, A. S.
    JOURNAL OF SURFACE INVESTIGATION, 2010, 4 (05): : 792 - 795
  • [3] Scanning helium ion microscope: Distribution of secondary electrons and ion channeling
    Yu. V. Petrov
    O. F. Vyvenko
    A. S. Bondarenko
    Journal of Surface Investigation. X-ray, Synchrotron and Neutron Techniques, 2010, 4 : 792 - 795
  • [4] Focal depth measurement of scanning helium ion microscope
    Guo, Hongxuan
    Itoh, Hiroshi
    Wang, Chunmei
    Zhang, Han
    Fujita, Daisuke
    APPLIED PHYSICS LETTERS, 2014, 105 (02)
  • [5] Helium ion microscope
    Scipioni, L.
    Stern, L.A.
    Notte, J.
    Sijbrandij, S.
    Griffin, B.
    Advanced Materials and Processes, 2008, 166 (06): : 27 - 30
  • [6] Helium ion microscope
    Scipioni, L.
    Stern, L. A.
    Notte, J.
    Sijbrandij, S.
    Griffin, B.
    ADVANCED MATERIALS & PROCESSES, 2008, 166 (06): : 27 - 30
  • [7] Scanning transmission helium ion microscopy on carbon nanomembranes
    Emmrich, Daniel
    Wolff, Annalena
    Meyerbroeker, Nikolaus
    Lindner, Jorg K. N.
    Beyer, Andre
    Goelzhaeuser, Armin
    BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2021, 12 : 222 - 231
  • [8] A COMPARISON OF DONOR MAPPING TECHNIQUES USING THE SCANNING HELIUM ION MICROSCOPE AND SCANNING ELECTRON MICROSCOPE
    Chee, Augustus
    2014 12TH IEEE INTERNATIONAL CONFERENCE ON SOLID-STATE AND INTEGRATED CIRCUIT TECHNOLOGY (ICSICT), 2014,
  • [9] A model of secondary electron imaging in the helium ion scanning microscope
    Ramachandra, Ranjan
    Griffin, Brendan
    Joy, David
    ULTRAMICROSCOPY, 2009, 109 (06) : 748 - 757