Evaluation of electromagnetic interference on telecommunication cables from an AC railway line: Measurements and calculations

被引:0
|
作者
Lucca, G
Moro, M
Ferrero, C
Giunta, M
机构
[1] SIRTI SpA, I-20127 Milan, Italy
[2] SIRTISISTEMI SpA, I-20127 Milan, Italy
[3] TILAB, I-10148 Turin, Italy
[4] Telecom Italia Lab, Turin, Italy
来源
关键词
D O I
10.1002/etep.4450130503
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper describes the main results of afield measurement campaign of the electromagnetic interference produced by a 25 kV - 50 Hz railway line on nearby telecommunication cables; the results of the measurements were compared with the results of calculations based on suitable circuit models for studying the inducing and induced systems. The results of the comparison were deemed satisfactory.
引用
收藏
页码:285 / 290
页数:6
相关论文
共 50 条
  • [1] Inductive interference caused to telecommunication cables by nearby AC electric traction lines. Measurements and FEM calculations
    Satsios, KJ
    Labridis, DP
    Dokopoulos, PS
    IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (02) : 588 - 594
  • [2] Analysis of electromagnetic interference on DC line from parallel AC line in close proximity
    Tang, Han
    Zeng, Rong
    Ma, Hongbin
    He, Jinhang
    Zhao, He
    Li, Xiaolin
    Wang, Qi
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (04) : 2401 - 2408
  • [3] Evaluation of electromagnetic interference from railway electric power system harmonics
    Pereira, ML
    Sartori, CAF
    Costa, MC
    Dietrich, AB
    Cardoso, JR
    2003 IEEE International Symposium on Electromagnetic Compatibility (EMC), Vols 1 and 2, Symposium Record, 2003, : 437 - 440
  • [4] Study on influence of AC electrified railway on electromagnetic interference of oil and gas pipelines along the line based on CDEGS
    Sheng, Wangqun
    Journal of Railway Science and Engineering, 2020, 17 (08) : 2101 - 2108
  • [5] Electrification of the Sardinian railway line. Electromagnetic compatibility with regard to telecommunication equipment
    Passi, Francesco
    Solbiati, GianLuigi
    Energia Elettrica, 1988, 65 (12): : 555 - 563
  • [6] The influence of nonhomogeneous earth on the inductive interference caused to telecommunication cables by nearby ac electric traction lines
    Satsios, KJ
    Labridis, DP
    Dokopoulos, PS
    IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (03) : 1016 - 1021
  • [7] The influence of nonhomogeneous earth on the inductive interference caused to telecommunication cables by nearby AC electric traction lines
    Satsios, KJ
    Labridis, DP
    Dokopoulos, PS
    8TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, PROCEEDINGS, VOLS 1 AND 2, 1998, : 369 - 375
  • [8] Fictitious multi-medium method and its application in electromagnetic shielding calculations of underground telecommunication cables
    Zou, J
    Yuan, JS
    Ma, XS
    ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS: CEEM'2000, PROCEEDINGS, 2000, : 292 - 295
  • [9] MEASUREMENTS AND ANALYSIS OF ELECTROMAGNETIC INTERFERENCE IN A RAILWAY SIGNAL BOX - A CASE STUDY
    Niska, Stefan
    Schunnesson, Hakan
    Kumar, Uday
    INTERNATIONAL JOURNAL OF RELIABILITY QUALITY & SAFETY ENGINEERING, 2011, 18 (03): : 285 - 303
  • [10] Transport and magnetization ac losses of ROEBEL assembled coated conductor cables: measurements and calculations
    Terzieva, Stanimira
    Vojenciak, Michail
    Pardo, Enric
    Grilli, Francesco
    Drechsler, Antje
    Kling, Andrea
    Kudymow, Andrej
    Goemoery, Fedor
    Goldacker, Wilfried
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2010, 23 (01):