Calibration of RGBD camera and cone-beam CT for 3D intra-operative mixed reality visualization

被引:25
|
作者
Lee, Sing Chun [1 ]
Fuerst, Bernhard [1 ,2 ]
Fotouhi, Javad [1 ]
Fischer, Marius [1 ,3 ]
Osgood, Greg [4 ]
Navab, Nassir [1 ,2 ]
机构
[1] Johns Hopkins Univ, Comp Aided Med Procedures, Baltimore, MD USA
[2] Tech Univ Munich, Comp Aided Med Procedures, D-80290 Munich, Germany
[3] Ludwig Maximilians Univ Munchen, Klinikum Innenstadt, Dept Trauma Surg, Munich, Germany
[4] Johns Hopkins Univ Hosp, Dept Orthopaed Surg, Orthopaed Trauma, Baltimore, MD 21287 USA
关键词
Augmented reality; Cone-beam CT; C-arm; Intra-operative imaging; 3D-3D calibration; NAVIGATION; RADIATION; FLUOROSCOPY; ACCURACY; SYSTEM;
D O I
10.1007/s11548-016-1396-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work proposes a novel algorithm to register cone-beam computed tomography (CBCT) volumes and 3D optical (RGBD) camera views. The co-registered real-time RGBD camera and CBCT imaging enable a novel augmented reality solution for orthopedic surgeries, which allows arbitrary views using digitally reconstructed radiographs overlaid on the reconstructed patient's surface without the need to move the C-arm. An RGBD camera is rigidly mounted on the C-arm near the detector. We introduce a calibration method based on the simultaneous reconstruction of the surface and the CBCT scan of an object. The transformation between the two coordinate spaces is recovered using Fast Point Feature Histogram descriptors and the Iterative Closest Point algorithm. Several experiments are performed to assess the repeatability and the accuracy of this method. Target registration error is measured on multiple visual and radio-opaque landmarks to evaluate the accuracy of the registration. Mixed reality visualizations from arbitrary angles are also presented for simulated orthopedic surgeries. To the best of our knowledge, this is the first calibration method which uses only tomographic and RGBD reconstructions. This means that the method does not impose a particular shape of the phantom. We demonstrate a marker-less calibration of CBCT volumes and 3D depth cameras, achieving reasonable registration accuracy. This design requires a one-time factory calibration, is self-contained, and could be integrated into existing mobile C-arms to provide real-time augmented reality views from arbitrary angles.
引用
收藏
页码:967 / 975
页数:9
相关论文
共 50 条
  • [1] Calibration of RGBD camera and cone-beam CT for 3D intra-operative mixed reality visualization
    Sing Chun Lee
    Bernhard Fuerst
    Javad Fotouhi
    Marius Fischer
    Greg Osgood
    Nassir Navab
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 967 - 975
  • [2] The use of Intra-operative Cone-Beam CT in Ameloblastoma Resection
    Davies, R.
    Fry, A.
    Cascarini, L.
    [J]. BRITISH JOURNAL OF SURGERY, 2019, 106 : 83 - 83
  • [3] Deformable Registration for Intra-Operative Cone-Beam CT Guidance of Head and Neck Surgery
    Nithiananthan, Sajendra
    Brock, Kristy K.
    Irish, Jonathan C.
    Siewerdsen, Jeffrey H.
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 3634 - +
  • [4] Demons Deformable Registration for Cone-Beam CT Guidance: Registration of Pre- and Intra-Operative Images
    Nithiananthan, S.
    Brock, K. K.
    Daly, M. J.
    Chan, H.
    Irish, J. C.
    Siewerdsen, J. H.
    [J]. MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [5] 3D Global Estimation and Augmented Reality Visualization of Intra-operative X-ray Dose
    Rodas, Nicolas Loy
    Padoy, Nicolas
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2014, PT I, 2014, 8673 : 415 - 422
  • [6] Cone-Beam Angle Dependency of 3D Models Computed from Cone-Beam CT Images
    Cho, Myung Hye
    Hegazy, Mohamed A. A.
    Cho, Min Hyoung
    Lee, Soo Yeol
    [J]. SENSORS, 2022, 22 (03)
  • [7] Feasability Study of Low-dose Intra-operative Cone-beam CT for Image-guided Surgery
    Han, Xiao
    Shi, Shuanghe
    Bian, Junguo
    Helm, Patrick
    Sidky, Emil Y.
    Pan, Xiaochuan
    [J]. MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [8] 3D cone-beam CT reconstruction for circular trajectories
    Grass, M
    Köhler, T
    Proksa, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02): : 329 - 347
  • [9] Intra-operative cone-beam CT (O-arm) and stereotactic navigation in acute spinal trauma surgery
    Schouten, Rowan
    Lee, Robert
    Boyd, Michael
    Paquette, Scott
    Dvorak, Marcel
    Kwon, Brian K.
    Fisher, Charles
    Street, John
    [J]. JOURNAL OF CLINICAL NEUROSCIENCE, 2012, 19 (08) : 1137 - 1143
  • [10] Intra-operative 3D ultrasound in neurosurgery
    Unsgaard, G
    Rygh, OM
    Selbekk, T
    Müller, TB
    Kolstad, F
    Lindseth, F
    Hernes, TAN
    [J]. ACTA NEUROCHIRURGICA, 2006, 148 (03) : 235 - 253