Functional magnetic resonance imaging of awake monkeys: some approaches for improving imaging quality

被引:25
|
作者
Chen, Gang [1 ,2 ,3 ]
Wang, Feng [2 ,3 ]
Dillenburger, Barbara C. [2 ,3 ]
Friedman, Robert M. [1 ]
Chen, Li M. [2 ,3 ]
Gore, John C. [2 ,3 ,4 ,5 ,6 ]
Avison, Malcolm J. [2 ,3 ,7 ,8 ]
Roe, Anna W. [1 ,2 ,3 ,5 ]
机构
[1] Vanderbilt Univ, Dept Psychol, Nashville, TN 37203 USA
[2] Vanderbilt Univ, Inst Imaging Sci, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Dept Radiol & Radiol Sci, Nashville, TN 37235 USA
[4] Vanderbilt Univ, Dept Phys & Astron, Nashville, TN 37235 USA
[5] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
[6] Vanderbilt Univ, Dept Mol Physiol & Biophys, Nashville, TN 37235 USA
[7] Vanderbilt Univ, Dept Pharmacol, Nashville, TN 37235 USA
[8] Vanderbilt Univ, Dept Neurol, Nashville, TN 37235 USA
关键词
Functional MRI; Nonhuman primate; Macaque monkey; Awake; Visual cortex; Data stability; OCULAR DOMINANCE COLUMNS; PRIMATE VISUAL-CORTEX; MACAQUE MONKEYS; PHYSIOLOGICAL NOISE; BEHAVING MONKEYS; CEREBRAL-CORTEX; TEMPORAL-LOBE; 1.5; T; FMRI; ORGANIZATION;
D O I
10.1016/j.mri.2011.09.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Functional magnetic resonance imaging (fMRI) at high magnetic field strength can suffer from serious degradation of image quality because of motion and physiological noise, as well as spatial distortions and signal losses due to susceptibility effects. Overcoming such limitations is essential for sensitive detection and reliable interpretation of fMRI data. These issues are particularly problematic in studies of awake animals. As part of our initial efforts to study functional brain activations in awake, behaving monkeys using fMRI at 4.7 T, we have developed acquisition and analysis procedures to improve image quality with encouraging results. We evaluated the influence of two main variables on image quality. First, we show how important the level of behavioral training is for obtaining good data stability and high temporal signal-to-noise ratios. In initial sessions, our typical scan session lasted 1.5 h, partitioned into short (<10 min) runs. During reward periods and breaks between runs, the monkey exhibited movements resulting in considerable image misregistrations. After a few months of extensive behavioral training, we were able to increase the length of individual runs and the total length of each session. The monkey learned to wait until the end of a block for fluid reward, resulting in longer periods of continuous acquisition. Each additional 60 training sessions extended the duration of each session by 60 min, culminating, after about 140 training sessions, in sessions that last about 4 h. As a result, the average translational movement decreased from over 500 mu m to less than 80 mu m, a displacement close to that observed in anesthetized monkeys scanned in a 7-T horizontal scanner. Another major source of distortion at high fields arises from susceptibility variations. To reduce such artifacts, we used segmented gradient-echo echo-planar imaging (EPI) sequences. Increasing the number of segments significantly decreased susceptibility artifacts and image distortion. Comparisons of images from functional runs using four segments with those using a single-shot EPI sequence revealed a roughly twofold improvement in functional signal-to-noise-ratio and 50% decrease in distortion. These methods enabled reliable detection of neural activation and permitted blood-oxygenation-level-dependent-based mapping of early visual areas in monkeys using a volume coil. In summary, both extensive behavioral training of monkeys and application of segmented gradient-echo EPI sequence improved signal-to-noise ratio and image quality. Understanding the effects these factors have is important for the application of high field imaging methods to the detection of submillimeter functional structures in the awake monkey brain. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:36 / 47
页数:12
相关论文
共 50 条
  • [1] Functional magnetic resonance imaging (fMRI) in anaesthetized and awake monkeys
    Logothetis, NK
    [J]. EUROPEAN JOURNAL OF NEUROSCIENCE, 2000, 12 : 183 - 183
  • [2] Functional magnetic resonance imaging in awake animals
    Ferris, Craig F.
    Smerkers, Brain
    Kulkarni, Praveen
    Caffrey, Martha
    Afacan, Onur
    Toddes, Steven
    Stolberg, Tara
    Febo, Marcelo
    [J]. REVIEWS IN THE NEUROSCIENCES, 2011, 22 (06) : 665 - 674
  • [3] Neural effects of MDMA as determined by functional magnetic resonance imaging and magnetic resonance spectroscopy in awake marmoset monkeys
    Meyer, Jerrold S.
    Brevard, Matthew E.
    Piper, Brian J.
    Ali, Syed F.
    Ferris, Craig F.
    [J]. CELLULAR AND MOLECULAR MECHANISMS OF DRUGS OF ABUSE AND NEUROTOXICITY: COCAINE, GHB, AND SUBSTITUTED AMPHETAMINES, 2006, 1074 : 365 - 376
  • [4] Functional magnetic resonance imaging in macaque monkeys
    Dubowitz, DJ
    Chen, D
    Atkinson, DJ
    Grieve, KL
    Bradley, WG
    Andersen, RA
    [J]. RADIOLOGY, 1998, 209P : 275 - 275
  • [5] Functional magnetic resonance imaging of macaque monkeys
    Nakahara, K
    [J]. IMAGING IN BIOLOGICAL RESEARCH, PT A, 2004, 385 : 84 - 90
  • [6] Functional magnetic resonance imaging of awake behaving macaques
    Goense, Jozien B. M.
    Whittingstall, Kevin
    Logothetis, Nikos K.
    [J]. METHODS, 2010, 50 (03) : 178 - 188
  • [7] Improving functional magnetic resonance imaging reproducibility
    Pernet, Cyril
    Poline, Jean-Baptiste
    [J]. GIGASCIENCE, 2015, 4
  • [8] Training Dogs for Awake, Unrestrained Functional Magnetic Resonance Imaging
    Strassberg, Lily R.
    Waggoner, L. Paul
    Deshpande, Gopikrishna
    Katz, Jeffrey S.
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (152):
  • [9] Identification of cortical lamination in awake monkeys by high resolution magnetic resonance imaging
    Chen, Gang
    Wang, Feng
    Gore, John C.
    Roe, Anna W.
    [J]. NEUROIMAGE, 2012, 59 (04) : 3441 - 3449
  • [10] TECHNICAL APPROACHES TO FUNCTIONAL MAGNETIC-RESONANCE-IMAGING
    BUCHER, SF
    SEELOS, KC
    STEHLING, MK
    OERTEL, WH
    REISER, M
    [J]. RADIOLOGE, 1995, 35 (04): : 228 - 236