Impact of Stent-Graft Development on Outcome of Endovascular Repair of Acute Traumatic Transection of the Thoracic Aorta

被引:11
|
作者
Canaud, Ludovic [1 ,2 ]
Joyeux, Frederic [1 ]
Berthet, Jean-Philippe [1 ,2 ]
Hireche, Kheira [1 ]
Marty-Ane, Charles [1 ]
Alric, Pierre [1 ,2 ]
机构
[1] Hop A de Villeneuve, Serv Chirurg Vasc & Thorac, Dept Vasc & Thorac Surg, F-34090 Montpellier, France
[2] Univ Montpellier, INSERM, U637, Montpellier, France
关键词
thoracic aorta; traumatic rupture; stent-graft; aortic transection; first-generation devices; second-generation devices; stent-graft design; SURGERY-OF-TRAUMA; RUPTURE; MULTICENTER; INJURIES; TRIAL;
D O I
10.1583/11-3502.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To analyze the impact of stent-graft design on the outcome of endovascular repair of acute traumatic thoracic aortic transection. Methods: Forty-eight patients (38 men; mean age 37+/-11 years) underwent endovascular repair for an acute traumatic aortic rupture between April 2001 and March 2011. Up to October 2007, 32 patients (mean age 41+/-16 years; group 1) were treated with the first generation of commercially available thoracic stent-grafts (10 Talent, 20 Excluder/ TAG, 2 Zenith). From November 2007, 16 patients (mean age 42+/-19 years; group 2) were treated with second-generation thoracic stent-grafts (13 Valiant and 3 C-TAG). The 2 groups were statistically comparable. Follow-up computed tomography was performed at 1 week; at 3 and 6 months; and annually thereafter. Results: In the 2 groups, the mortality rate related to aortic repair was nil. All the patients have completed each of their scheduled follow-up evaluations and CT scans. The morbidity rate was significantly reduced (p = 0.0003) from 18.7% (first generation) to 6.2% (second generation). Type I endoleak (n = 1), inadvertent coverage of the supra-aortic trunks (n = 3), and stent-graft collapse (n = 2) occurred only with the first-generation stent-grafts. One iliac artery rupture occurred with a second-generation stent-graft. Conclusion: Enhanced stent-graft conformability and more accurate delivery systems have significantly decreased the morbidity of endovascular repair of acute traumatic transection of the thoracic aorta. The increasing clinical experience may also have contributed to improved results. J Endovasc Ther. 2011; 18: 485-490
引用
收藏
页码:485 / 490
页数:6
相关论文
共 50 条
  • [1] Immediate endovascular stent-graft repair of an acute traumatic rupture of the thoracic aorta - Case report and subject review
    Duncan, IC
    Wright, NC
    Fingleson, LM
    Coetzee, JIC
    SOUTH AFRICAN JOURNAL OF SURGERY, 2004, 42 (02) : 47 - 50
  • [2] Stent-graft repair in acute and chronic diseases of the thoracic aorta
    Kische, Stephan
    Akin, Ibrahim
    Ince, Hueseyin
    Rehders, Tim C.
    Schneider, Henrik
    Ortak, Jasmin
    Nienaber, Christoph A.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2008, 61 (10): : 1070 - 1086
  • [3] Use of thoracic endovascular aortic repair in acute traumatic transection of the thoracic aorta
    Whittaker, B.
    Gorecha, M.
    Kothare, P.
    ANAESTHESIA, 2016, 71 : 38 - 38
  • [4] Endovascular Repair of Blunt Traumatic Innominate Artery Transection With a Covered Stent-Graft
    Dang, Tru
    Bui, Allen
    Katz, Marc
    Wooster, Mathew
    JOURNAL OF VASCULAR SURGERY, 2021, 74 (04) : E353 - E354
  • [5] Stent-graft repair for acute traumatic thoracic aortic rupture
    Neuhauser, B
    Czermak, B
    Jaschke, W
    Waldenberger, P
    Fraedrich, G
    Perkmann, R
    AMERICAN SURGEON, 2004, 70 (12) : 1039 - 1044
  • [6] ENDOVASCULAR AORTIC STENT GRAFT REPAIR FOR BLUNT TRAUMATIC THORACIC AORTIC TRANSECTION
    Saleh, Ayman
    Potemkowski, Antoni
    Abu-Zidan, Fikri M.
    SINGAPORE MEDICAL JOURNAL, 2008, 49 (10) : 847 - 848
  • [7] Endovascular stent-graft placement for acute and contained rupture of the descending thoracic aorta
    Eggebrecht, H
    Schmermund, A
    Herold, U
    Baumgart, D
    Martini, S
    Kuhnt, O
    Lind, AY
    Kühne, C
    Kühl, H
    Kienbaum, P
    Peters, J
    Jakob, HG
    Erbel, R
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (04) : 474 - 482
  • [8] Endovascular stent-graft repair of complicated penetrating atherosclerotic ulcers of the descending thoracic aorta
    Schoder, M
    Grabenwöger, M
    Hölzenbein, T
    Domanovits, H
    Fleischmann, D
    Wolf, F
    Cejna, M
    Lammer, J
    JOURNAL OF VASCULAR SURGERY, 2002, 36 (04) : 720 - 726
  • [9] Endovascular stent-graft repair of thoracic aortic aneurysms
    Mitchell, RS
    Dake, MD
    Semba, CP
    Fogarty, TJ
    Zarins, CK
    Liddell, RP
    Miller, DC
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (05): : 1054 - 1060
  • [10] Endovascular stent-graft treatment for diseases of the descending thoracic aorta
    Bortone, AS
    Schena, S
    Mannatrizio, G
    Paradiso, V
    Ferlan, G
    Dialetto, G
    Cotrufo, M
    Schinosa, LDT
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 20 (03) : 514 - 519