Randomized Comparison of 3 Hemostasis Techniques After Transradial Coronary Intervention

被引:20
|
作者
Cong, Xiaoliang [1 ]
Huang, Zhigang [1 ]
Wu, Jia [1 ]
Wang, Jiamei [1 ]
Wen, Feng [1 ]
Fang, Lingling [1 ]
Fan, Min [2 ]
Liang, Chun [2 ]
机构
[1] Changzheng Hosp, Dept Cardiol, 415 Rd Fengyang, Shanghai 200433, Peoples R China
[2] Changzheng Hosp, Dept Cardiol, Med, Shanghai, Peoples R China
关键词
coronary angiography; percutaneous coronary intervention; vascular complication; RADIAL ARTERY-OCCLUSION; CATHETERIZATION; COMPRESSION; ANGIOGRAPHY; DEVICES; FLOW;
D O I
10.1097/JCN.0000000000000268
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The transradial route for coronary intervention has proven to be a safe and feasible method, and several techniques have been shown to be effective in achieving hemostasis. Objectives: The aim of this study is to evaluate the efficacy of 3 hemostasis techniques on radial artery outcomes after transradial catheterization. Methods: A total of 1650 patients were randomly assigned to 1 of the 3 hemostasis techniques after the procedure. The outcome measures were local vascular complications, tolerance to the device, and the time taken to achieve hemostasis. Results: Time taken to achieve hemostasis was significantly longer in the pressure dressing (PD) group than in the pneumatic compression device (PCD) group and rotary compression pad device (RCD) group (306 +/- 65 vs 263 +/- 62 and 237 +/- 58 minutes; P < .0001). There were also significant differences between PD, PCD, and RCD groups with respect to the incidence of oozing (8.2% vs 5.1% and 5.1%; P = .047) and discomfort level (1.68 vs 1.43 and 1.40; P < .0001). The incidence of early (24 hours after the procedure) radial artery occlusion was significantly higher in the PD group than in the PCD and RCD groups (15.6% vs 5.8% and 4.5%; P < .0001). Logistic regression analysis showed that independent predictors of radial artery occlusion at 30-day follow-up visit were diabetes (hazard ratio, 2.39), larger radial artery diameter (hazard ratio, 0.52), the use of the PCD (hazard ratio, 0.51, compared with PD) and the RCD (hazard ratio, 0.52, compared with PD), and radial artery patency during compression (hazard ratio, 0.016). Conclusions: Hemostasis devices have comparative advantages over the conventional pressure dressing. The presence of radial artery flow during compression represents a strong predictor of radial artery patency during follow-up periods.
引用
收藏
页码:445 / 451
页数:7
相关论文
共 50 条
  • [1] A Comparison of 2 Devices for Radial Artery Hemostasis After Transradial Coronary Intervention
    Dai, Neng
    Xu, Da-chun
    Hou, Lei
    Peng, Wen-hui
    Wei, Yi-dong
    Xu, Ya-Wei
    JOURNAL OF CARDIOVASCULAR NURSING, 2015, 30 (03) : 192 - 196
  • [2] Patent hemostasis and comparison of two compression devices after transradial coronary catheterization and intervention
    Jirous, Stepan
    Bernat, Ivo
    Durspek, Jan
    Rokyta, Richard
    COR ET VASA, 2018, 60 (02) : E122 - E126
  • [3] Hemostasis After Transradial Coronary Interventions
    Edmundson, Allyson N.
    Folmar, Jessica
    Jobe, R. Lee
    Mann, Tift
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 239I - 240I
  • [4] Predictors of Incomplete Hemostasis After Transradial Coronary Intervention: A Prospective Cohort Study
    Ahn, Jong-Hwa
    Park, Yongwhi
    Chon, Min-Ku
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B243 - B243
  • [5] A Randomized Comparison of TR Band and Radistop Hemostatic Compression Devices After Transradial Coronary Intervention
    Rathore, Sudhir
    Stables, Rodney H.
    Pauriah, Maheshwar
    Hakeem, Abdul
    Mills, Joseph D.
    Palmer, Nick D.
    Perry, Raphael A.
    Morris, John L.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (05) : 660 - 667
  • [6] A randomized trial of vascular hemostasis techniques to reduce femoral vascular complications after coronary intervention
    Pracyk, JB
    Wall, TC
    Longabaugh, JP
    Tice, FD
    Hochrein, J
    Green, C
    Cox, G
    Lee, K
    Stack, RS
    Tcheng, JE
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (08): : 970 - 976
  • [7] Comparison of Two Hemostasis Methods After Percutaneous Coronary Intervention
    Xu, Yanmin
    Li, Guangping
    Xu, Gang
    Yin, Li
    Yuan, Ruyu
    Zheng, Xintian
    Chen, Xin
    CIRCULATION, 2010, 122 (02) : E332 - E332
  • [8] Comparison of two hemostasis methods after percutaneous coronary intervention
    徐延敏
    林小静
    李广平
    许纲
    尹力
    袁如玉
    郑心田
    陈新
    South China Journal of Cardiology, 2010, 11 (02) : 96 - 100
  • [9] Hemostasis pad combined with compression device after transradial coronary procedures: A randomized controlled trial
    Kang, Si-Hyuck
    Han, Donghoon
    Kim, Sehun
    Yoon, Chang-Hwan
    Park, Jin-Joo
    Suh, Jung-Won
    Cho, Young-Seok
    Youn, Tae-Jin
    Chae, In-Ho
    PLOS ONE, 2017, 12 (07):
  • [10] Randomized comparison of hemostasis techniques after invasive cardiovascular procedures
    Lehmann, KG
    Heath-Lange, SJ
    Ferris, ST
    AMERICAN HEART JOURNAL, 1999, 138 (06) : 1118 - 1125