Validation of prompt gamma-ray spectroscopy for proton range verification in tissue-mimicking and porcine samples

被引:5
|
作者
Tattenberg, Sebastian [1 ,2 ,3 ]
Marants, Raanan [3 ,4 ]
Niepel, Katharina [1 ]
Bortfeld, Thomas [2 ,3 ]
Sudhyadhom, Atchar [3 ,4 ]
Landry, Guillaume [5 ,6 ]
Parodi, Katia [1 ]
Verburg, Joost [2 ,3 ]
机构
[1] Ludwig Maximilians Univ Munchen, Fac Phys, Dept Med Phys, Garching, Germany
[2] Massachusetts Gen Hosp, Dept Radiat Oncol, Div Radiat Biophys, Boston, MA 02114 USA
[3] Harvard Med Sch, Boston, MA 02115 USA
[4] Brigham & Womens Hosp, Dept Radiat Oncol, Dana Farber Canc Inst, 75 Francis St, Boston, MA 02115 USA
[5] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiat Oncol, Munich, Germany
[6] German Canc Consortium DKTK, Partner Site Munich, Munich, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2022年 / 67卷 / 20期
关键词
range uncertainty; proton therapy; range verification; prompt gamma-ray spectroscopy; EMISSION; SIMULATION; PATIENT; PET;
D O I
10.1088/1361-6560/ac950f
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Proton therapy of cancer improves dose conformality to the target and sparing of surrounding healthy tissues compared to conventional photon treatments. However, proton therapy's advantage could be even larger if proton range uncertainties were reduced. Sources of range uncertainties include computed tomography treatment planning images and variations in patient anatomy and setup. To reduce range uncertainties, we have developed a system for real-time in vivo range monitoring. The system is based on spectroscopy of prompt gamma-rays emitted through proton-nuclear interactions during irradiation. We validated the performance of our prompt gamm-aray spectroscopy detector prototype using tissue-mimicking and porcine samples. Approach. Measurements were performed in water, four tissue-mimicking samples (spongiosa, muscle, adipose tissue, and cortical bone), and two porcine samples (liver and brain). A dose of 0.9 Gy was delivered to a target at a depth of 12.5-17.5 cm. Multi-layer ionization chamber measurements were performed to determine stopping power ratios relative to water and ground truth proton ranges. Ground truth elemental compositions were determined using combustion analysis. Proton ranges and elemental compositions measured using prompt gamma-ray spectroscopy were compared to the ground truth. Main results. For all samples, the mean measured range over all pencil-beam spots differed from the ground truth by less than 1.2 mm. The mean standard deviation was 0.9 mm (range: 0.4 1.6 mm). The mean difference between ground truth and measured elemental compositions was 0.06 8/cm(3) (range: 0.00 g/cm(3) to 0.12 g/cm(3)). Significance. We verified the performance of our prompt gamma-ray spectroscopy detector prototype for proton range verification using tissue-mimicking and porcine samples. Measured proton ranges and elemental sample compositions were in good agreement with the ground truth. These measurements confirm the system's reliability for a variety of tissues and bridge the gap between previously-reported experiments and ongoing in vivo patient measurements.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Proton range verification through prompt gamma-ray spectroscopy
    Verburg, Joost M.
    Seco, Joao
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23): : 7089 - 7106
  • [2] Prompt Gamma-Ray Spectroscopy Validation for Real-Time Proton Range Verification
    Tattenberg, S.
    Marants, R.
    Niepel, K.
    Bortfeld, T.
    Sudhyadhom, A.
    Landry, G.
    Parodi, K.
    Verburg, J.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E534 - E535
  • [3] Prompt Gamma-Ray Spectroscopy for Range Verification of Clinical Proton Beams
    Verburg, J.
    Bortfeld, T.
    Seco, J.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3548 - 3548
  • [4] Clinical Translation of Prompt Gamma-Ray Spectroscopy for In Vivo Proton Range Verification
    Verburg, J.
    Ruggieri, T.
    Botas, P.
    Cascio, E.
    Hueso-Gonzalez, F.
    Rabe, M.
    BortfeId, T.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [5] A Prompt Gamma-Ray Spectroscopy System for Clinical Studies of in Vivo Proton Range Verification
    Verburg, J.
    Bortfeld, T.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3757 - 3757
  • [6] Development of a Clinical Prototype for Range Verification in Proton Therapy based on Prompt Gamma-Ray Spectroscopy
    Hueso-Gonzalez, F.
    Rabe, M.
    Ruggieri, T. A.
    Bortfeld, T.
    Verburg, J. M.
    [J]. 2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [7] Proton Beam Range Verification with a Single Prompt Gamma-Ray Detector
    Verburg, J.
    Testa, M.
    Cascio, E.
    Bortfeld, T.
    Lu, H.
    Seco, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 495 - 495
  • [8] A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy
    Hueso-Gonzalez, Fernando
    Rabe, Moritz
    Ruggieri, Thomas A.
    Bortfeld, Thomas
    Verburg, Joost M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (18):
  • [9] Proton Range Verification with Submillimeter Precision Using a Full Scale Prototype Prompt Gamma-Ray Spectroscopy System
    Verburg, J.
    Gonzalez, F. Hueso
    Bortfeld, T.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E510 - E510
  • [10] Range verification of passively scattered proton beams using prompt gamma-ray detection
    Verburg, Joost M.
    Testa, Mauro
    Seco, Joao
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03): : 1019 - 1029