Bifurcated drum occluder endograft for treatment of abdominal aortic aneurysm:: An experimental study in dogs

被引:4
|
作者
Pavcnik, D
Uchida, BT
Timmermans, H
Petersen, B
Loriaux, M
Yamakado, K
Voda, J
Yin, Q
Keller, FS
Rösch, J
机构
[1] Oregon Hlth Sci Univ, Dotter Intervent Inst, Portland, OR 97201 USA
[2] Oregon Hlth Sci Univ, Dept Pathol, Portland, OR 97201 USA
[3] Oregon Hlth Sci Univ, Sect Liver & Pancreas Transplantat, Portland, OR 97201 USA
关键词
aneurysm; aortic; stents and prostheses; interventional procedures; experimental;
D O I
10.1016/S1051-0443(07)61917-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate a new, low profile, home-made, bifurcated drum occluder endograft (BDOEG), designed for percutaneous, transcatheter treatment of abdominal aortic aneurysm (AAA). MATERIALS AND METHODS: AAA was created in 10 dogs with over-dilated Palmaz stents. To prevent back filling, the lumbar arteries, inferior mesenteric artery, and common internal iliac arteries were embolized. The BDOEG was constructed of a drum occluder device and two PTFE endografts. The drum device consisted of a modified Z stent with Dacron stretched across and held within the ends of the stent, each with two 8 x 6-mm slits through which PTFE endografts were delivered. The PTFE endografts were 8 mm in diameter and 9.5 cm in length. Preloaded, the BDOEG was delivered through a 10-F sheath from both femoral arteries in a three-step procedure. All 10 animals were treated with BDOEG. Aortography was performed immediately, 6 weeks, and 12 weeks after stent-graft placement. Five animals were killed at 6 weeks and five were killed at 3 months. Gross and histologic evaluation was performed. RESULTS: The infrarenal aortic diameters and both external iliac arteries ranged from 8.0 mm to 10.3 mm (mean, 9.4 mm +/- 0.6) and from 5.2 mm to 6.8 mm (mean, 5.8 mm +/- 0.5), respectively. Creation of the AAA was successful in all 10 dogs. AAA diameters ranged from 13.7 mm to 15.9 mm (mean, 14.9 mm +/- 0.7). Complete exclusion of the AAA was achieved immediately after BDOEG placement and aneurysms remained excluded without perigraft leak to the time of killing in all 10 animals. There was a high incidence of aortoiliac limb occlusion. Occlusion of 12 aortoiliac limbs (60%) caused by intimal hyperplasia at the distal end of the endografts in iliac arteries developed in nine animals (90%). In six animals (60%), one limb occluded and, in three animals (30%), there was occlusion of both limbs. CONCLUSION: This study suggests a new approach for treatment of AAA. BDOEG use reduces sheath size for endograft delivery and may eliminate the need for a surgical cut down on femoral arteries. Tapering of the iliac ends of endografts to the size of the artery will be needed to prevent distal intimal hyperplasia.
引用
收藏
页码:359 / 364
页数:6
相关论文
共 50 条
  • [1] Unpredictable Late Rupture of an Abdominal Aortic Aneurysm After Bifurcated Ancure Endograft Repair
    Rosen, Noah A.
    Cayne, Neal S.
    Macari, Michael
    Jacobowitz, Glenn R.
    VASCULAR AND ENDOVASCULAR SURGERY, 2008, 42 (01) : 69 - 73
  • [2] Abdominal aortic bifurcation anatomy and endograft limb size affect the use of adjunctive iliac stenting after bifurcated endograft deployment for abdominal aortic aneurysm
    Bianchini Massoni, Claudio
    Gargiulo, Mauro
    Freyrie, Antonio
    Gallitto, Enrico
    De Matteis, Massimo
    Mascoli, Chiara
    Stella, Andrea
    JOURNAL OF CARDIOVASCULAR SURGERY, 2018, 59 (02): : 237 - 242
  • [3] Ultrasound imaging during endovascular abdominal aortic aneurysm repair using the stentor bifurcated endograft
    Lie, T
    Lundbom, J
    Hatlinghus, S
    Gronningsaeter, A
    Ommedal, S
    Aadahl, P
    Saether, OD
    Myhre, HO
    JOURNAL OF ENDOVASCULAR SURGERY, 1997, 4 (03): : 272 - 278
  • [4] Endovascular treatment of acute abdominal aortic aneurysm with a bifurcated stentgraft
    Kapma, MR
    Verhoeven, ELG
    Tielliu, IFJ
    Zeebregts, CJAM
    Prins, TR
    Van der Heij, B
    Van den Dungen, JJAM
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2005, 29 (05) : 510 - 515
  • [5] Bifurcated iliac endograft in a patient with aortic-iliac aneurysm
    Mertens M, Renato
    Kraemer Sch, Albrecht
    Valdes E, Francisco
    Marine M, Leopoldo
    Bergoeing R, Michel
    REVISTA CHILENA DE CIRUGIA, 2010, 62 (03): : 279 - 284
  • [6] Bifurcated Abdominal Aortic Endograft Deployment via the Carotid Artery
    Paravastu, S.
    Farquharson, F.
    Serracino-Inglott, F.
    ANNALS OF VASCULAR SURGERY, 2010, 24 (04) : 552.e5 - 552.e8
  • [7] Five-year interim comparison of the Guidant bifurcated endograft with open repair of abdominal aortic aneurysm
    Moore, WS
    Matsumura, JS
    Makaroun, MS
    Katzen, BT
    Deaton, DH
    Decker, M
    Walker, G
    JOURNAL OF VASCULAR SURGERY, 2003, 38 (01) : 46 - 55
  • [8] Mid-term comparison of bifurcated modular endograft versus aorto-uni-iliac endograft in patients with abdominal aortic aneurysm
    Dalainas, Ilias
    Moros, Ioannis
    Gerasimidis, Thomas
    Papadimitriou, Dimitris
    Saratzis, Nikos
    Gitas, Christos G.
    Kiskinis, Dimitrios
    Lazaridis, Jean
    ANNALS OF VASCULAR SURGERY, 2007, 21 (03) : 339 - 345
  • [9] TREATMENT OF ABDOMINAL AORTIC-ANEURYSM WITH THE EVT-EGS ENDOGRAFT
    GOMES, AS
    MOORE, WS
    QUINONESBALDRICH, WJ
    YOON, H
    VESCERA, CL
    RADIOLOGY, 1995, 197 : 234 - 234
  • [10] TREATMENT OF ABDOMINAL AORTIC-ANEURYSM WITH THE EVT-EGS ENDOGRAFT
    GOMES, AS
    MOORE, WS
    QUINONESBALDRICH, WJ
    YOON, HC
    VESCERA, CL
    CIRCULATION, 1995, 92 (08) : 601 - 601