Proton exchange membrane water electrolysis at high current densities: Investigation of thermal limitations

被引:23
|
作者
Moeckl, Maximilian [1 ]
Bernt, Maximilian [1 ]
Schroeter, Jonas [1 ]
Jossen, Andreas [2 ]
机构
[1] ZAE Bayern, Electrochem Energy Storage, Walther Meigner Str 6, D-85748 Garching, Germany
[2] Tech Univ Munich, Dept Elect & Comp Engn, Chair Elect Energy Storage Technol, Karlstr 45, D-80333 Munich, Germany
关键词
Proton exchange membrane water electrolysis (PEMWE); High current density operation; Thermal limitation; Heat transport; POWER-TO-GAS; HIGH-PRESSURE; IN-SITU; TEMPERATURE SENSOR; PEM; OPERATION; MODEL; PERFORMANCE; HYDROGEN; HEAT;
D O I
10.1016/j.ijhydene.2019.11.144
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this work the thermal limitations of high current density proton exchange membrane water electrolysis are investigated by the use of a one dimensional model. The model encompasses in-cell heat transport from the membrane electrode assembly to the flow field channels. It is validated by in-situ temperature measurements using thin bare wire thermocouples integrated into the membrane electrode assemblies based on Nafion 117 membranes in a 5 cm(2) cell setup. Heat conductivities of the porous transport layers, titanium sinter metal and carbon paper, between membrane electrode assembly and flow fields are measured in the relevant operating temperature range of 40 degrees C - 90 degrees C for application in the model. Additionally, high current density experiments up to 25 A/cm(2) are conducted with Nafion 117, Nafion (R) 212 and Nafion XL based membrane electrode assemblies. Experimental results are in agreement with the heat transport model. It is shown that for anode-only water circulation, water flows around 25 ml/(min cm(2)) are necessary for an effective heat removal in steady state operation at 10 A/cm(2), 80 degrees C water inlet temperature and 90 degrees C maximum membrane electrode assembly temperature. The measured cell voltage at this current density is 2,05 V which corresponds to a cell efficiency of 61 % based on lower heating value. Operation at these high current densities results in three to ten-fold higher power density compared to current state of the art proton exchange membrane water electrolysers. This would drastically lower the material usage and the capital expenditures for the electrolysis cell stack. (C) 2019 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1417 / 1428
页数:12
相关论文
共 50 条
  • [1] Proton exchange membrane water electrolysis at high current densities: Response time and gas-water distribution
    Bai, Jinhao
    Li, Zifeng
    Zhang, Jingchang
    Guan, Xiaoping
    Yang, Ning
    [J]. AICHE JOURNAL, 2023, 69 (12)
  • [2] Numerical Investigation of Flow Field Distributions and Water and Thermal Management for a Proton Exchange Membrane Electrolysis Cell
    Shao, Dan
    Hu, Liangyong
    Zhang, Guoqing
    Hu, Kaicheng
    Zhang, Jiangyun
    Liu, Jun
    Peng, Kang
    Jiang, Liqin
    Jiang, Wenzhao
    Wen, Yuliang
    [J]. ENERGIES, 2024, 17 (14)
  • [3] Water Crossover in Proton Exchange Membrane Water Electrolysis
    Friedrichs-Schucht, M.
    Hasche, F.
    Oezaslan, M.
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (07)
  • [4] Numerical investigation of water and temperature distributions in a proton exchange membrane electrolysis cell
    WANG ZhiMing
    XU Chao
    WANG XueYe
    LIAO ZhiRong
    DU XiaoZe
    [J]. Science China Technological Sciences, 2021, 64 (07) : 1555 - 1566
  • [5] Numerical investigation of water and temperature distributions in a proton exchange membrane electrolysis cell
    ZhiMing Wang
    Chao Xu
    XueYe Wang
    ZhiRong Liao
    XiaoZe Du
    [J]. Science China Technological Sciences, 2021, 64 : 1555 - 1566
  • [6] Numerical investigation of water and temperature distributions in a proton exchange membrane electrolysis cell
    Wang ZhiMing
    Xu Chao
    Wang XueYe
    Liao ZhiRong
    Du XiaoZe
    [J]. SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2021, 64 (07) : 1555 - 1566
  • [7] Numerical investigation of water and temperature distributions in a proton exchange membrane electrolysis cell
    WANG ZhiMing
    XU Chao
    WANG XueYe
    LIAO ZhiRong
    DU XiaoZe
    [J]. Science China(Technological Sciences), 2021, (07) - 1566+1596
  • [8] High-pressure proton exchange membrane water electrolysis: Current status and challenges in hydrogen production
    Bin, Shiyu
    Chen, Zeyi
    Zhu, Yanxi
    Zhang, Yixiang
    Xia, Yan
    Gong, Shihao
    Zhang, Fanhang
    Shi, Lei
    Duan, Xiongbo
    Sun, Zhiqiang
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 67 : 390 - 405
  • [9] Proton exchange membrane electrolysis sustained by water vapor
    Spurgeon, Joshua M.
    Lewis, Nathan S.
    [J]. ENERGY & ENVIRONMENTAL SCIENCE, 2011, 4 (08) : 2993 - 2998
  • [10] Recent advances in proton exchange membrane water electrolysis
    Liu, Rui-Ting
    Xu, Zheng-Long
    Li, Fu-Min
    Chen, Fei-Yang
    Yu, Jing-Ya
    Yan, Ya
    Chen, Yu
    Xia, Bao Yu
    [J]. CHEMICAL SOCIETY REVIEWS, 2023, 52 (16) : 5652 - 5683