A comparison of methods to detect postural transitions using a single tri-axial accelerometer

被引:0
|
作者
Godfrey, Alan [1 ]
Barry, Gillian [1 ]
Mathers, John C. [2 ]
Rochester, Lynn [1 ]
机构
[1] Newcastle Univ, Clin Ageing Res Unit, Newcastle Upon Tyne NE4 5PL, Tyne & Wear, England
[2] Newcastle Univ, Human Nutr Res Ctr, Inst Ageing & Hlth, Newcastle Upon Tyne NE4 5PL, Tyne & Wear, England
基金
英国医学研究理事会;
关键词
STAND; SIT;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two algorithms for evaluating postural transitions (PTs) in cohorts of 40 healthy younger and 40 older adults are described and evaluated. The time of sit-to-stand (SiSt) and stand-to-sit (StSi) transitions and their duration were measured with two tri-axial accelerometers, one on the chest and one on the lower back. Each algorithm was optimized for these sensor placements. The first algorithm for sensor placement on the chest used a scalar product and vertical velocity estimates. The second algorithm for sensor placement on the lower back used a vector magnitude and a discrete wavelet transform. Both algorithms performed excellently in PT classification for younger and older adults (>86%). However, the chest based sensor and algorithm were better for estimating transition duration (TD) with ICCs to video analysis ranging from 0.678 to 0.969.
引用
收藏
页码:6234 / 6237
页数:4
相关论文
共 50 条
  • [1] ASSESSMENT OF POSTURAL INSTABILITY IN PATIENTS WITH A NEUROLOGICAL DISORDER USING A TRI-AXIAL ACCELEROMETER
    Hanakova, Lenka
    Socha, Vladimir
    Schlenker, Jakub
    Cakrt, Ondrej
    Kutilek, Patrik
    ACTA POLYTECHNICA, 2015, 55 (04) : 229 - 236
  • [2] Quantifying lumbar mobility using a single tri-axial accelerometer
    Evans, David W.
    Wong, Ian T. Y.
    Leung, Hoi Kam
    Yang, Hanyun
    Liew, Bernard X. W.
    HELIYON, 2024, 10 (11)
  • [3] Activity classification using a single chest mounted tri-axial accelerometer
    Godfrey, A.
    Bourke, A. K.
    Olaighin, G. M.
    van de Ven, P.
    Nelson, J.
    MEDICAL ENGINEERING & PHYSICS, 2011, 33 (09) : 1127 - 1135
  • [4] Validity and Reliability of Gait and Postural Control Analysis Using the Tri-axial Accelerometer of the iPod Touch
    Nienke M. Kosse
    Simone Caljouw
    Danique Vervoort
    Nicolas Vuillerme
    Claudine J. C. Lamoth
    Annals of Biomedical Engineering, 2015, 43 : 1935 - 1946
  • [5] Improvements to Calibration Modeling of a Tri-Axial Accelerometer Using Response Surface Methods
    Toro, Kenneth G.
    Ponder, Jonathon D.
    Parker, Peter A.
    2024 IEEE INTERNATIONAL SYMPOSIUM ON INERTIAL SENSORS AND SYSTEMS, INERTIAL, 2024,
  • [6] Human Gait Classification Using a Tri-axial Accelerometer
    Lotfi, Ahmad
    Minh Nguyen
    Langensiepen, Caroline
    8TH ACM INTERNATIONAL CONFERENCE ON PERVASIVE TECHNOLOGIES RELATED TO ASSISTIVE ENVIRONMENTS (PETRA 2015), 2015,
  • [7] Validity and Reliability of Gait and Postural Control Analysis Using the Tri-axial Accelerometer of the iPod Touch
    Kosse, Nienke M.
    Caljouw, Simone
    Vervoort, Danique
    Vuillerme, Nicolas
    Lamoth, Claudine J. C.
    ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (08) : 1935 - 1946
  • [8] Categorising sheep activity using a tri-axial accelerometer
    Barwick, Jamie
    Lamb, David W.
    Dobos, Robin
    Welch, Mitchell
    Trotter, Mark
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2018, 145 : 289 - 297
  • [9] Methods for Person Recognition and Abnormal Gait Detection Using Tri-axial Accelerometer and Gyroscope
    Guan-Wei He
    Min-Hsuan Lin
    Yu-Tai Ching
    PROCEEDINGS 2017 INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE AND COMPUTATIONAL INTELLIGENCE (CSCI), 2017, : 1691 - 1694
  • [10] Gait and posture discrimination in sheep using a tri-axial accelerometer
    Radeski, M.
    Ilieski, V.
    ANIMAL, 2017, 11 (07) : 1249 - 1257