Interrater Agreement and Detection Accuracy for Medium-Vessel Occlusions Using Single-Phase and Multiphase CT Angiography

被引:22
|
作者
Ospel, J. M. [1 ,3 ]
Bala, F. [1 ]
McDonough, R. V. [1 ]
Volny, O. [4 ,5 ]
Kashani, N. [1 ,2 ]
Qiu, W. [1 ]
Menon, B. K. [1 ,2 ]
Goyal, M. [1 ,2 ]
机构
[1] Univ Calgary, Dept Diagnost Imaging, Calgary, AB, Canada
[2] Univ Calgary, Dept Clin Neurosci, Calgary, AB, Canada
[3] Univ Hosp Basel, Dept Radiol, Basel, Switzerland
[4] Masaryk Univ, Czech Natl Ctr Evidence Based Healthcare & Knowle, Brno, Czech Republic
[5] Univ Hosp Ostrava, Dept Neurol, Ostrava, Czech Republic
基金
加拿大健康研究院;
关键词
ACUTE ISCHEMIC-STROKE;
D O I
10.3174/ajnr.A7361
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Accurate and reliable detection of medium-vessel occlusions is important to establish the diagnosis of acute ischemic stroke and initiate appropriate treatment with intravenous thrombolysis or endovascular thrombectomy. However, medium-vessel occlusions are often challenging to detect, especially for unexperienced readers. We aimed to evaluate the accuracy and interrater agreement of the detection of medium-vessel occlusions using single-phase and multiphase CTA. MATERIALS AND METHODS: Single-phase and multiphase CTA of 120 patients with acute ischemic stroke (20 with no occlusion, 44 with large-vessel occlusion, and 56 with medium-vessel occlusion in the anterior and posterior circulation) were assessed by 3 readers with varying levels of experience (session 1: single-phase CTA; session 2: multiphase CTA). Interrater agreement for occlusion type (large-vessel occlusion versus medium-vessel occlusion versus no occlusion) and for detailed occlusion sites was calculated using the Fleiss ? with 95% confidence intervals. Accuracy for the detection of medium-vessel occlusions was calculated for each reader using classification tables. RESULTS: Interrater agreement for occlusion type was moderate for single-phase CTA (? ?=?0.58; 95% CI, 0.56?0.62) and almost perfect for multiphase CTA (? = 0.81; 95% CI, 0.78?0.83). Interrater agreement for detailed occlusion sites was moderate for single-phase CTA (? = 0.55; 95% CI, 0.53?0.56) and substantial for multiphase CTA (? = 0.71; 95% CI, 0.67?0.74). On single-phase CTA, readers 1, 2, and 3 classified 33/56 (59%), 34/56 (61%), and 32/56 (57%) correctly as medium-vessel occlusions. On multiphase CTA, 48/56 (86%), 50/56 (89%), and 50/56 (89%) medium-vessel occlusions were classified correctly. CONCLUSIONS: Interrater agreement for medium-vessel occlusions is moderate when using single-phase CTA and almost perfect with multiphase CTA. Detection accuracy is substantially higher with multiphase CTA compared with single-phase CTA, suggesting that multiphase CTA might be a valuable tool for assessment of medium-vessel occlusion stroke.
引用
收藏
页码:93 / 97
页数:5
相关论文
共 24 条
  • [1] Missed Medium-Vessel Occlusions on CT Angiography: Make It Easier ... Easily!
    Ospel, J. M.
    Qiu, W.
    Goyal, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2020, 41 (09) : E73 - E74
  • [2] Finding MeVO: Identifying Intracranial Medium-Vessel Occlusions at CT Angiography
    Wayer, Daniel R.
    Nigogosyan, Zack
    Xie, Victoria
    Mian, Ali Y.
    Holder, Derek L.
    Kim, Thomas A.
    Vo, Katie D.
    Chatterjee, Arindam Rano
    Goyal, Manu S.
    RADIOGRAPHICS, 2024, 44 (11)
  • [3] Missed Medium-Vessel Occlusions on CT Angiography: Make It Easier ... Easily! REPLY
    Fasen, B. A.
    Kwee, R. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2020, 41 (09) : E75 - E75
  • [4] Effects of multiphase versus single-phase CT angiography for the detection of distal cerebral vessel occlusion
    Hefferman, Gerald M.
    Baird, Grayson L.
    Swenson, David W.
    Ward, Robert C.
    Jayaraman, Mahesh V.
    Cutting, Shawna
    Jindal, Gaurav
    EMERGENCY RADIOLOGY, 2021, 28 (05) : 891 - 898
  • [5] Effects of multiphase versus single-phase CT angiography for the detection of distal cerebral vessel occlusion
    Gerald M. Hefferman
    Grayson L. Baird
    David W. Swenson
    Robert C. Ward
    Mahesh V. Jayaraman
    Shawna Cutting
    Gaurav Jindal
    Emergency Radiology, 2021, 28 : 891 - 898
  • [6] Improved Detection of Anterior Circulation Occlusions: The "Delayed Vessel Sign" on Multiphase CT Angiography
    Byrne, D.
    Sugrue, G.
    Stanley, E.
    Walsh, J. P.
    Murphy, S.
    Kavanagh, E. C.
    MacMahon, P. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (10) : 1911 - 1916
  • [7] Artificial Intelligence and Multiphase CT Angiography for Detection of Large Vessel Occlusions: A Powerful Combination
    Ospel, Johanna M.
    Goyal, Mayank
    RADIOLOGY, 2020, 297 (03) : 650 - 651
  • [8] Detection of single-phase CTA occult vessel occlusions in acute ischemic stroke using CT perfusion-based wavelet-transformed angiography
    Kunz, Wolfgang G.
    Sommer, Wieland H.
    Havla, Lukas
    Dorn, Franziska
    Meinel, Felix G.
    Dietrich, Olaf
    Buchholz, Grete
    Ertl-Wagner, Birgit
    Thierfelder, Kolja M.
    EUROPEAN RADIOLOGY, 2017, 27 (06) : 2657 - 2664
  • [9] Detection of single-phase CTA occult vessel occlusions in acute ischemic stroke using CT perfusion-based wavelet-transformed angiography
    Wolfgang G. Kunz
    Wieland H. Sommer
    Lukas Havla
    Franziska Dorn
    Felix G. Meinel
    Olaf Dietrich
    Grete Buchholz
    Birgit Ertl-Wagner
    Kolja M. Thierfelder
    European Radiology, 2017, 27 : 2657 - 2664
  • [10] Multiphase CT angiography versus single-phase CT angiography: Comparison of image quality and radiation dose
    Yang, C. -Y.
    Chen, Y. -F.
    Lee, C. -W.
    Huang, A.
    Shen, Y.
    Wei, C.
    Liu, H. -M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (07) : 1288 - 1295