Product analysis of partial discharge damage to oil-impregnated insulation paper

被引:31
|
作者
Yan, Jiaming [1 ]
Liao, Ruijin [1 ]
Yang, Lijun [1 ]
Li, Jian [1 ]
Liu, Bin [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
关键词
IR; XPS; GC-MS; Surface droplets; Crystalline solids; Electronegative gases; ELECTRICAL-PROPERTIES; POWER TRANSFORMERS; COTTON STALKS; EPOXY-RESIN; FT-IR; DEGRADATION; CELLULOSE; WOOD;
D O I
10.1016/j.apsusc.2011.01.125
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Surface products of oil-impregnated insulation paper during the damage process caused by partial discharge (PD), as well as gas within the cavity, were studied. An optical microscope and a scanning electron microscope (SEM) were used to investigate surface morphology, while an infrared spectroscopy (IR) and an X-ray photoelectron spectroscopy (XPS) were used to study surface products and their components. The volume variation in cavity gas was also analyzed. Furthermore, gas constituents and their relevant contents were studied using a gas chromatography-mass spectrometer (GC-MS). The study results reveal the following: during the PD damage process, the total gas volume and the content of electronegative gasses alternately decline and increase, while discharge types alternate between pulse type and pseudo-glow type (or glow type); "surface droplets" and "crystalline solids" appear on the insulation surface one after another; surface droplets mainly consist of (C=O)-group-containing compounds, whereas crystalline solids are mainly carboxylic acids, with carboxyl groups also found in cellulose chains; and the discharge type related to the oxidization of decomposition products is the main factor that determines the state (liquid or solid) of the surface products. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:5863 / 5870
页数:8
相关论文
共 50 条
  • [1] Measurements and analysis of surface damage on oil-impregnated insulation paper caused by partial discharge
    Yan, Jiaming
    Liao, Ruijin
    Yang, Lijun
    Zhu, Mengzhao
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (05)
  • [2] Analysis of damage on oil-impregnated insulation paper using phase distribution of partial discharge
    Yan, Jia-Ming
    Liao, Rui-Jin
    Yang, Li-Jun
    Deng, Xiao-Pin
    Li, Wei
    [J]. Gaodianya Jishu/High Voltage Engineering, 2010, 36 (10): : 2488 - 2493
  • [3] Partial discharge behaviour in oil-impregnated insulation
    Khawaja, RH
    Ariastina, WG
    Blackburn, TR
    [J]. PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 1166 - 1169
  • [4] Investigation of partial discharge properties in oil-impregnated insulation
    Ariastina, W. G.
    Khawaja, R. H.
    Blackburn, T. R.
    [J]. ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 714 - +
  • [5] Influence of Oil-impregnated Paper Insulation Aging Status on Surface Partial Discharge Characteristics
    Zhang, Weizheng
    Li, Zhimin
    Guo, Jumei
    Ji, Guojian
    Liu, Bin
    [J]. 4TH INTERNATIONAL CONFERENCE ON MECHANICAL AUTOMATION AND MATERIALS ENGINEERING (ICMAME 2015), 2015, : 194 - 198
  • [6] The Relationship Between Surface Partial Discharge and Carbon Trace in Oil-Impregnated Paper Insulation
    Cheng, Yangchun
    Li, Chengrong
    Miao, Yinyin
    [J]. CEIDP: 2009 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2009, : 702 - +
  • [7] Cluster Classification of Partial Discharges in Oil-impregnated Paper Insulation
    Suresh, S. D. R.
    Usa, S.
    [J]. ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2010, 10 (01) : 90 - 93
  • [8] The UHF method for measurement of partial discharge in oil-impregnated insulation
    Chen, QG
    Gong, XX
    Gao, WS
    Li, FQ
    Tan, KX
    [J]. PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 451 - 454
  • [9] Development of partial discharge in oil-impregnated insulation and its effect
    Wang, Xiao-Rong
    Hu, Long-Long
    Zhang, Guan-Jun
    Yan, Zhang
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2001, 21 (SUPPL.): : 173 - 176
  • [10] Aging of Oil-impregnated Transformer Insulation Studied through Partial Discharge Analysis
    Chen, X.
    Morshuis, P. H. F.
    Zhuang, Q.
    Smit, J. J.
    Xu, Z.
    [J]. PROCEEDINGS OF THE 2010 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS (ICSD 2010), 2010,