Quantitative image quality evaluation for Cardiac CT reconstructions

被引:0
|
作者
Tseng, Hsin-Wu [1 ,2 ]
Fan, Jiahua [2 ]
Kupinski, Matthew A. [1 ]
Balhorn, William [2 ]
Okerlund, Darin R. [2 ]
机构
[1] Univ Arizona, Coll Opt Sci, Tucson, AZ 85721 USA
[2] GE Healthcare, CT Engn, Waukesha, WI 53188 USA
关键词
Cardiac CT; CT; Motion Compensation; SnapShot Freeze (SSF); Image Quality;
D O I
10.1117/12.2208341
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Maintaining image quality in the presence of motion is always desirable and challenging in clinical Cardiac CT imaging. Different image-reconstruction algorithms are available on current commercial CT systems that attempt to achieve this goal. It is widely accepted that image-quality assessment should be task-based and involve specific tasks, observers, and associated figures of merits. In this work, we developed an observer model that performed the task of estimating the percentage of plaque in a vessel from CT images. We compared task performance of Cardiac CT image data reconstructed using a conventional FBP reconstruction algorithm and the SnapShot Freeze (SSF) algorithm, each at default and optimal reconstruction cardiac phases. The purpose of this work is to design an approach for quantitative image-quality evaluation of temporal resolution for Cardiac CT systems. To simulate heart motion, a moving coronary type phantom synchronized with an ECG signal was used. Three different percentage plaques embedded in a 3 mm vessel phantom were imaged multiple times under motion free, 60 bpm, and 80 bpm heart rates. Static (motion free) images of this phantom were taken as reference images for image template generation. Independent ROIs from the 60 bpm and 80 bpm images were generated by vessel tracking. The observer performed estimation tasks using these ROIs. Ensemble mean square error (EMSE) was used as the figure of merit. Results suggest that the quality of SSF images is superior to the quality of FBP images in higher heart-rate scans.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Enhancing cardiac CT imaging quality: Precision metrics for assessing image quality for AI-powered reconstructions
    Longere, Benjamin
    Dacher, Jean-Nicolas
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (03) : 85 - 86
  • [2] Equating quantitative emphysema measurements on different CT image reconstructions
    Bartel, Seth T.
    Bierhals, Andrew J.
    Pilgram, Thomas K.
    Hong, Cheng
    Schechtman, Kenneth B.
    Conradi, Susan H.
    Gierada, David S.
    MEDICAL PHYSICS, 2011, 38 (08) : 4894 - 4902
  • [3] Methods for quantitative image quality evaluation of MRI parallel reconstructions: detection and perceptual difference model
    Jiang, Yuhao
    Huo, Donglai
    Wilson, David L.
    MAGNETIC RESONANCE IMAGING, 2007, 25 (05) : 712 - 721
  • [4] Evaluation of compressed chest CT image quality using quantitative analysis
    Yamamoto, S
    Matsumoto, T
    Ueguchi, T
    Joukou, T
    Umeda, T
    Sasagaki, M
    Sukenobu, Y
    Honda, I
    Kawahara, M
    Cruz, M
    Hanayama, M
    Kusumi, Y
    Nakamura, H
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 892 - 892
  • [5] Feasibility of the Quantitative Assessment Method for CT Quality Control in Phantom Image Evaluation
    Lee, Ki Baek
    Nam, Ki Chang
    Jang, Ji Sung
    Kim, Ho Chul
    APPLIED SCIENCES-BASEL, 2021, 11 (08):
  • [6] Image quality evaluation of motion-contaminated calcified plaques in cardiac CT
    King, Martin
    Giger, Maryellen
    Suzuki, Kenji
    Pan, Xiaochuan
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2717 - 2720
  • [7] An Approach for Quantitative Image Quality Analysis for CT
    Rahimi, Amir
    Cochran, Joe
    Mooney, Doug
    Regensburger, Joe
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [8] Quantitative Evaluation of Image Quality in Low Dose CT Images Obtained by Deep Learning
    Lee, D.
    Kim, H.
    MEDICAL PHYSICS, 2019, 46 (06) : E171 - E171
  • [9] GEOMETRICAL ACCURACY AND IMAGE QUALITY OF CT RECONSTRUCTIONS FROM VMAT PORTAL IMAGES
    Thomas, M.
    Poludniowski, G.
    Evans, P.
    Webb, S.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S494 - S494
  • [10] Quantitative Evaluation of a Spectral CT Scanner in a Phantom Study: Results of Spectral Reconstructions
    Duan, X.
    Arbique, G.
    Guild, J.
    Yagil, Y.
    Anderson, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3836 - 3837