Behaviour of Partially Closed Stiffened Cold-Formed Steel Compression Member

被引:14
|
作者
Manikandan, P. [1 ]
Arun, N. [1 ]
机构
[1] KS Rangasamy Coll Technol, Dept Civil Engn, Tiruchengode 637215, Tamil Nadu, India
关键词
Partially closed column; Stiffened column; Spacer plates; Numerical analysis; Distortional buckling; Intermediate column; EDGE STIFFENERS; DESIGN; STRENGTH; FAILURE;
D O I
10.1007/s13369-015-2015-0
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Usually, thin-walled open column sections have an intrinsic weakness in their low torsional strength, which is unpleasant for resistance of an open section. The distortion behaviour of cold-formed steel open section has a significant role in structural steel design. Hence, initiativeness is made for converting partially closed section by adding simple spacer plates connected with self-tapping screws. The intend of this work is tested to estimate the competence of this solution by comparing the strength and performance of partially closed and open stiffened complex channel section under axial compression. The buckling characteristics of the section are computed using the linear elastic buckling analysis program CUFSM. The resistance and behaviour of the intermediate columns are examined in detail using finite element analysis software ANSYS. A good conformity between finite element analysis and experiments is found. The nominal design capacities are evaluated using the necessities of the direct strength method, North American iron and steel specification and Indian standard and are compared with those from test and finite element analysis. After this verification of the numerical model, a crucial parametric study is carried out to inspect the effect of vitiations on thickness, depth, spacing and slenderness of spacer plates. The particulars of this study and results are offered in this research article.
引用
收藏
页码:3865 / 3875
页数:11
相关论文
共 50 条
  • [1] Behaviour of Partially Closed Stiffened Cold-Formed Steel Compression Member
    P. Manikandan
    N. Arun
    Arabian Journal for Science and Engineering, 2016, 41 : 3865 - 3875
  • [2] Flexural behaviour of stiffened cold-formed steel rectangular hollow sections
    Setiyawan, Prabowo
    Osman, Mohd Hanim
    Saim, A. Aziz
    RAHMAN, Ahmad Baharuddin Abd.
    Faridmehr, Iman
    International Journal of Earth Sciences and Engineering, 2014, 7 (03): : 1072 - 1081
  • [3] THE BEHAVIOUR OF COLD-FORMED STEEL PLAIN ANCHOR PLATE IN COMPRESSION
    Ng, A. L. Y.
    Mei, C. C.
    Proceedings of the 7th International Conference on Steel and Aluminium Structures (ICSAS 2011), 2011, : 328 - 333
  • [4] Behaviour of GFRP Stiffened Cold-Formed Steel Built-up Beams
    Suhaib, Mir Basar
    Tantray, M. A.
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2022, 22 (04) : 1042 - 1059
  • [5] Behaviour of GFRP Stiffened Cold-Formed Steel Built-up Beams
    Mir Basar Suhaib
    M. A. Tantray
    International Journal of Steel Structures, 2022, 22 : 1042 - 1059
  • [6] Cold-formed steel flexural member with edge stiffened holes: Behavior, optimization, and design
    Yu, Cheng
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 71 : 210 - 218
  • [7] Effects of edge-stiffened web openings on the behaviour of cold-formed steel channel sections under compression
    Chen, Boshan
    Roy, Krishanu
    Uzzaman, Asraf
    Raftery, Gary M.
    Nash, David
    Clifton, G. Charles
    Pouladi, Pouya
    Lim, James B. P.
    THIN-WALLED STRUCTURES, 2019, 144
  • [8] BEHAVIOUR OF COLD-FORMED STEEL SINGLE AND COMPOUND PLAIN ANGLES IN COMPRESSION
    Vishnuvardhan, S.
    Knight, G. M. Samuel
    ADVANCED STEEL CONSTRUCTION, 2008, 4 (01): : 47 - 59
  • [9] Behaviour of cold-formed steel single and compound plain angles in compression
    Department of Civil Engineering, Tagore Engineering College, Vandalur, Chennai 600 048, India
    不详
    Adv. Steel Constr., 2008, 1 (46-58):
  • [10] EFFECTIVE WIDTH OF STIFFENED COLD-FORMED STEEL PLATES
    ROORDA, J
    VENKATARAMAIAH, KR
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1979, 6 (03) : 381 - 389