Fabrication of a poly(dimethylsiloxane)-based electrochemiluminescence detection cell for capillary electrophoresis

被引:17
|
作者
Yan, JL [1 ]
Yang, XR [1 ]
Wang, EK [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Peoples R China
关键词
D O I
10.1021/ac050581g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An easy but effective technique is described here for quick fabrication of low-cost electrochemiluminescence detection cells for capillary electrophoresis. The technique is based on molding of poly(dimethylsiloxane) (PDMS) with a capillary column inserted into a pipet tip. Two access holes are left in the PDMS slab; they provide neat accommodations for the separation capillary and the working electrode made with the same type of tip. Since the access holes are well-aligned, the electrode and the capillary are automatically aligned; thus, end-column detection is easily obtained. Fabrication of the detection cell is straightforward; no micromechanical operation is included. Also the principle for the procedure makes it possible to efficiently batch production detection cells with good reproducibility. Because of the end-column scheme, the cell can be adopted for electrophoresis with electrochemical detection as well.
引用
收藏
页码:5385 / 5388
页数:4
相关论文
共 50 条
  • [1] Fabrication of poly(dimethylsiloxane)-based capillary electrophoresis microchips using epoxy templates
    Chen, G
    Bao, HM
    Li, JH
    Chen, D
    MICROCHIMICA ACTA, 2006, 153 (3-4) : 151 - 158
  • [2] Fabrication of Poly(dimethylsiloxane)-Based Capillary Electrophoresis Microchips Using Epoxy Templates
    Gang Chen
    Huimin Bao
    Jianhua Li
    Di Chen
    Microchimica Acta, 2006, 153 : 151 - 158
  • [3] Chemiluminescence detection for a microchip capillary electrophoresis system fabricated in poly(dimethylsiloxane)
    Liu, BF
    Ozaki, M
    Utsumi, Y
    Hattori, T
    Terabe, S
    ANALYTICAL CHEMISTRY, 2003, 75 (01) : 36 - 41
  • [4] Capillary electrophoresis and microchip capillary electrophoresis with electrochemical and electrochemiluminescence detection
    Du, Yan
    Wang, Erkang
    JOURNAL OF SEPARATION SCIENCE, 2007, 30 (06) : 875 - 890
  • [5] Capillary electrophoresis with indirect electrochemiluminescence detection
    Kang, JZ
    Liu, JF
    Yin, XB
    Qiu, HB
    Yan, JL
    Yang, XR
    Wang, EK
    ANALYTICAL LETTERS, 2005, 38 (07) : 1179 - 1191
  • [6] Determination of mefenacet by capillary electrophoresis with electrochemiluminescence detection
    Liu, SC
    Liu, YJ
    Li, J
    Guo, ML
    Pan, W
    Yao, SZ
    TALANTA, 2006, 69 (01) : 154 - 159
  • [7] Analysis of monosaccharides by capillary electrophoresis with electrochemiluminescence detection
    Li, Ming
    Lee, Sang Hak
    ANALYTICAL SCIENCES, 2007, 23 (11) : 1347 - 1349
  • [8] Analysis of Monosaccharides by Capillary Electrophoresis with Electrochemiluminescence Detection
    Ming Li
    Sang Hak Lee
    Analytical Sciences, 2007, 23 : 1347 - 1349
  • [9] Dual-electrode electrochemical detection for poly(dimethylsiloxane)-fabricated capillary electrophoresis microchips
    Martin, RS
    Gawron, AJ
    Lunte, SM
    Henry, CS
    ANALYTICAL CHEMISTRY, 2000, 72 (14) : 3196 - 3202
  • [10] Rapid fabrication of poly(dimethylsiloxane)-based microchip capillary electrophoresis devices using CO2 laser ablation
    Fogarty, BA
    Heppert, KE
    Cory, TJ
    Hulbutta, KR
    Martin, RS
    Lunte, SM
    ANALYST, 2005, 130 (06) : 924 - 930