Thermal performance analysis of a novel geothermal Organic Rankine cycle-bypass flash system based on the latent heat proportion of working fluids

被引:6
|
作者
Li, Weikang [1 ]
Bu, Shujuan [1 ]
Yang, Xinle [2 ]
Huang, Feifei [3 ]
Tang, Meiling [1 ]
Ji, Zhixin [1 ]
Dai, Wenzhi [1 ]
Su, Chang [1 ]
Liu, Xunan [1 ]
机构
[1] Liaoning Tech Univ, Sch Mech Engn, Fuxin 123000, Peoples R China
[2] Liaoning Tech Univ, Dev Ctr New Energy, Fuxin 123000, Peoples R China
[3] Guodian Suzhou Second Thermal Power Co Ltd, Suzhou 234000, Anhui, Peoples R China
关键词
Geothermal water; Saturation temperature of heat source; Latent heat proportion of working fluids; Bypass flash system; Thermal performance; POINT TEMPERATURE DIFFERENCE; PINCH POINT; EXERGOECONOMIC ANALYSIS; ORC; OPTIMIZATION; PLANT; SIMULATION; SELECTION; DESIGN; SINGLE;
D O I
10.1016/j.egyr.2021.10.062
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To reduce the temperature difference of the heat exchanger and improve the thermal performance of organic Rankine cycle (ORC), a novel geothermal ORC-bypass flash system (ORC-f) is proposed. In this system, the latent heat proportion of working fluid and the saturated temperature of heat source are used as the basis for judgments. Further, the influence of heat source temperature and evaporation temperature on the ORC-f system is analyzed with different working fluids and compared with that of ORC system. The results show that when the heat source temperature is 403.15 K, the evaporation temperature is 313 K and 397 K, using R123 with higher latent heat proportion as working fluid, the net output power of ORC-f system is increased by 6.3 kW and 551.23 kW than that of the ORC system; using R114 with lower latent heat proportion as working fluid, the net output power of the ORC-f system is increased by 3.8 kW and 547.4 kW than that of the ORC system. When the saturated heat source temperature is not reached, the working fluid with higher latent heat proportion is used, the net output power and exergy efficiency of the ORC-f system are larger; When the saturated heat source temperature is reached, there is no need to increase the bypass flash system. Further, the thermal performance of the different working fluids of the ORC-f system is similar, and the ORC-f system can reduce the influence of the working fluid on the thermal performance. (C) 2021 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:6806 / 6819
页数:14
相关论文
共 50 条
  • [1] Thermal performance analysis on the new organic rankine cycle-bypass flash system considering the temperature difference of heat exchanger
    Yang, Xinle
    Huang, Feifei
    Li, Weikang
    Dai, Wenzhi
    Dong, Sihan
    [J]. Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2015, 51 (08): : 151 - 157
  • [2] Effect of the working fluids critical temperature on thermal performance for trilateral flash cycle and organic Rankine cycle
    Imre A.R.
    Ahmed A.M.
    [J]. International Journal of Thermofluids, 2023, 20
  • [3] THERMODYNAMIC ANALYSIS OF GEOTHERMAL HEAT SOURCED ORGANIC RANKINE CYCLE FOR DIFFERENT ORGANIC FLUIDS
    Cimsit, Canan
    [J]. ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2019, 39 (02) : 169 - 177
  • [4] Optimization of mixed working fluids for a novel trigeneration system based on organic Rankine cycle installed with heat pumps
    Li, Zishen
    Li, Weiyi
    Xu, Borui
    [J]. APPLIED THERMAL ENGINEERING, 2016, 94 : 754 - 762
  • [5] Thermal efficiency investigation for organic Rankine cycle and trilateral flash cycle using hydrofluoroether working fluids
    Ahmed, Aram M.
    [J]. RESULTS IN ENGINEERING, 2024, 21
  • [6] Selection of the best working fluid for low temperature steam organic Rankine cycle system with combined regeneration based on the proportion of latent heat
    Yang, Xinle
    Huang, Feifei
    Dai, Wenzhi
    Xiao, Xiaochun
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 (08): : 1969 - 1976
  • [7] Evaluation of Working Fluids for Organic Rankine Cycle Based on Exergy Analysis
    Setiawan, D.
    Subrata, I. D. M.
    Purwanto, Y. A.
    Tambunan, A. H.
    [J]. 2ND INTERNATIONAL CONFERENCE ON AGRICULTURAL ENGINEERING FOR SUSTAINABLE AGRICULTURAL PRODUCTION (AESAP 2017), 2018, 147
  • [8] Development of a geothermal-flash organic Rankine cycle-based combined system with solar heat upgrade
    Altayib, Khalid
    Dincer, Ibrahim
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2022, 252
  • [9] Novel molecules as working fluids for refrigeration, heat pump and organic Rankine cycle systems
    Gimenez-Prades, P.
    Navarro-Esbri, J.
    Arpagaus, C.
    Fernandez-Moreno, A.
    Mota-Babiloni, A.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2022, 167
  • [10] Analysis of Thermal Performance of Organic Rankine Cycle With Zeotropic Mixture Working Fluids Based on Gibbs Free Energy Change
    Bu S.
    Yang X.
    Li W.
    Su C.
    Dai W.
    Wang X.
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (14): : 5212 - 5220